Online 2D High-pH and Low-pH Reversed-Phase Nano-LC-MS/MS System for Deep Proteome Analysis
被引:2
|
作者:
论文数: 引用数:
h-index:
机构:
Liu, Yu-Ching
[1
,2
]
Chen, Chao-Jung
论文数: 0引用数: 0
h-index: 0
机构:
China Med Univ, Grad Inst Integrated Med, Taichung 404333, Taiwan
China Med Univ Hosp, Dept Med Res, Prote Core Lab, Taichung 404327, TaiwanChina Med Univ, Grad Inst Integrated Med, Taichung 404333, Taiwan
Chen, Chao-Jung
[1
,2
]
机构:
[1] China Med Univ, Grad Inst Integrated Med, Taichung 404333, Taiwan
[2] China Med Univ Hosp, Dept Med Res, Prote Core Lab, Taichung 404327, Taiwan
In bottom-up proteomic profiling, the complexity of proteome composition and wide dynamic range has created challenges on the limited number of protein identification and proteome coverage, especially in sample input-limited nanoflow (nano) LC-MS/MS analysis. Herein, we developed a fully automatic online 2D nano-LC-MS/MS system using both high-pH and low-pH reverse phase (RP) LCs on a single LC instrument toward comprehensive proteomics analysis. Compared to conven-tional microflow 2D-LC, the high-pH RP trapping column demonstrated a low sample requirement of cellular protein digest at the mu g level with good fractionation resolution of >90% peptides in a single fraction. Compared to the offline 2D RP-RP nano-LC-QTOF using C18-HPLC column and C18-Stage Tip, and 1D nano-LC-QTOF system, superior coverage was observed on the higher number of identified protein groups/unique peptides by 1.35-/1.68-, 1.46-/1.75-, and 3.21-/4.35-fold, respectively, using an online 2D RP-RP nano-LC-QTOF mass spectrometer. On the evolution of quantitation performance, the online 2D high-/low-pH RP data-independent acquisition (DIA) showed a higher reproducibility in protein groups intensity (R2 > 0.977) and more quantified proteins than that obtained using the offline 2D high-/low-pH RP DIA approach. Using an advanced Orbitrap Exploris 480 mass spectrometer, similar to 1.9-fold higher proteome coverage was also observed in our 2D online RP-RP system (6039 protein groups) compared to the 1D nano-LC system (3133 protein groups). In summary, the online 2D nano-LC-MS/MS platform can be a sensitive and robust approach compatible with conventional nano-LC instruments for deep proteome coverage of trace amounts of samples.
机构:
Exonox Biosci Inc, Taipei, TaiwanChina Med Univ, Grad Inst Integrated Med, Taichung, Taiwan
Huang, Yu-Ting
Chen, Chao-Jung
论文数: 0引用数: 0
h-index: 0
机构:
China Med Univ, Grad Inst Integrated Med, Taichung, Taiwan
China Med Univ Hosp, Dept Med Res, Prote Core Lab, Taichung, TaiwanChina Med Univ, Grad Inst Integrated Med, Taichung, Taiwan
机构:
Univ North Carolina Greensboro, Ctr Translat Biomed Res, North Carolina Res Campus, Kannapolis, NC 28081 USAUniv North Carolina Greensboro, Ctr Translat Biomed Res, North Carolina Res Campus, Kannapolis, NC 28081 USA
Zhang, Lina
Liu, Chih-Wei
论文数: 0引用数: 0
h-index: 0
机构:
Univ North Carolina Greensboro, Ctr Translat Biomed Res, North Carolina Res Campus, Kannapolis, NC 28081 USAUniv North Carolina Greensboro, Ctr Translat Biomed Res, North Carolina Res Campus, Kannapolis, NC 28081 USA
Liu, Chih-Wei
Zhang, Qibin
论文数: 0引用数: 0
h-index: 0
机构:
Univ North Carolina Greensboro, Ctr Translat Biomed Res, North Carolina Res Campus, Kannapolis, NC 28081 USA
Univ N Carolina, Dept Chem & Biochem, Greensboro, NC 27412 USAUniv North Carolina Greensboro, Ctr Translat Biomed Res, North Carolina Res Campus, Kannapolis, NC 28081 USA