A Novel Approach of Customized Pelvic Implant Design Based on Symmetrical Analysis and 3D Printing

被引:3
作者
Chai, Yuan [1 ]
Chen, Xiao-Bo [2 ]
Estoque, Jesse A. [1 ]
Birbilis, Nick [3 ]
Qin, Qinghua [3 ]
Ward, Tomas [4 ]
Smith, Paul N. [5 ]
Li, Rachel W. [6 ]
机构
[1] Australian Natl Univ, Med Sch, Dept Surg, Trauma & Orthopaed Res Lab, Canberra, ACT, Australia
[2] RMIT Univ, Sch Engn, Carlton, Vic, Australia
[3] Australian Natl Univ, Coll Engn & Comp Sci, Canberra, ACT, Australia
[4] Canberra Hosp, Dept Emergency, Canberra, ACT, Australia
[5] Canberra Hosp, Trauma & Orthopaed Res Unit, Clin Orthopaed Surg, Canberra, ACT, Australia
[6] Australian Natl Univ, John Curtin Sch Med Res, Garran Rd, Acton, ACT 2601, Australia
基金
澳大利亚研究理事会;
关键词
customized implant; 3D printing; pelvic fracture; symmetrical analysis; anatomical design; geometrical fit; BILATERAL ASYMMETRY; RECONSTRUCTION; PLATE;
D O I
10.1089/3dp.2021.0121
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In pelvic trauma patients, the mismatch of complex geometries between the pelvis and fixation implant is a fundamental cause of unstable and displaced pelvic ring disruption, in which secondary intervention is strongly considered. The geometrical matching in the current customized implant design and clinical practice is through the nonfractured hemi-pelvis for the fractured pelvis. This design philosophy overlooks the anatomical difference between the hemipelves, and further, the geometrical asymmetry at local area still remains unknown. This study analyzed the anatomical asymmetry of a patient's 3D pelvic models from 13 patients. The hemipelves of each patient were registered by using an iterative closet algorithm to an optimum position with minimum deviations. The high deviation regions were summarized between the hemipelves in each case, and a color map was drawn on a hemipelvis model that identified the areas that had a high possibility to be symmetrically different. A severe pelvic trauma case was used to comprehend the approach by designing a 3D printed implant. Each fracture was then registered to the mirrored uninjured hemipelvis by using the same algorithm, and customized fixation implants were designed with reference to the fractured model. The customized fixation plates showed that the implants had lower geometrical deviation when attached onto the re-stitched fracture side than onto the mirrored nonfractured bone. These results indicate that the symmetrical analysis of bone anatomy and the deviation color map can assist with implant selection and customized implant design given the geometrical difference between symmetrical bones. The novel approach provides a scientific reference that improves the accuracy and overall standard of 3D printed implants.
引用
收藏
页码:984 / 991
页数:8
相关论文
共 39 条
[1]   Three-dimensional study of pelvic asymmetry on anatomical specimens and its clinical perspectives [J].
Boulay, C ;
Tardieu, C ;
Bénaim, C ;
Hecquet, J ;
Marty, C ;
Prat-Pradal, D ;
Legaye, J ;
Duval-Beaupère, G ;
Pélissier, J .
JOURNAL OF ANATOMY, 2006, 208 (01) :21-33
[2]   The Value of 3D Printed Models in Understanding Acetabular Fractures [J].
Brouwers, Lars ;
ter Gunne, Albert F. Pull ;
de Jongh, Mariska A. C. ;
van der Heijden, Frank H. W. M. ;
Leenen, Luke P. H. ;
Spanjersberg, Willem R. ;
van Helden, Sven H. ;
Verbeek, Diederik O. ;
Bemelman, Mike ;
Lansink, Koen W. W. .
3D PRINTING AND ADDITIVE MANUFACTURING, 2018, 5 (01) :37-45
[3]   Laser polished fused deposition poly-lactic acid objects for personalized orthopaedic application [J].
Chai, Yuan ;
Chen, Xiao-Bo ;
Zhang, Donghai ;
Lynch, Joseph ;
Birbilis, Nick ;
Qin, Qing-Hua ;
Smith, Paul N. ;
Li, Rachel W. .
SN APPLIED SCIENCES, 2020, 2 (11)
[4]   Laser polishing of thermoplastics fabricated using fused deposition modelling [J].
Chai, Yuan ;
Li, Rachel W. ;
Perriman, Diana M. ;
Chen, Song ;
Qin, Qing-Hua ;
Smith, Paul N. .
INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2018, 96 (9-12) :4295-4302
[5]   3D surgical printing and pre contoured plates for acetabular fractures [J].
Chana-Rodriguez, Francisco ;
Mananes, Ruben Perez ;
Rojo-Manaute, Jose ;
Gil, Pablo ;
Martinez-Gomiz, Jose Maria ;
Vaquero-Martin, Javier .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (11) :2507-2511
[6]   Image-guided installation of 3D-printed patient-specific implant and its application in pelvic tumor resection and reconstruction surgery [J].
Chen, Xiaojun ;
Xu, Lu ;
Wang, Yiping ;
Hao, Yongqiang ;
Wang, Liao .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2016, 125 :66-78
[7]  
Culler Steven D, 2017, Arthroplast Today, V3, P257, DOI [10.1016/j.artd.2017.05.001, 10.1016/j.artd.2017.05.001]
[8]   Bony asymmetry in patellofemoral morphology and risk factors of instability are mostly clinically negligible [J].
Dagneaux, Louis ;
Razak, Hamid Rahmatullah Bin Abd ;
Laumonerie, Pierre ;
Faizhan, Ahmad ;
LiArno, Sally ;
Wellings, Peter ;
Ollivier, Matthieu ;
Jacquet, Christophe .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (11) :3793-3799
[9]   Implantation of customized 3-D printed titanium prosthesis in limb salvage surgery: a case series and review of the literature [J].
Fan, Hongbin ;
Fu, Jun ;
Li, Xiangdong ;
Pei, Yanjun ;
Li, Xiaokang ;
Pei, Guoxian ;
Guo, Zheng .
WORLD JOURNAL OF SURGICAL ONCOLOGY, 2015, 13
[10]   A RETROSPECTIVE ANALYSIS OF PLATE CONTOURING IN THE TIBIA USING THE CONVENTIONAL 4.5 (NARROW) DYNAMIC COMPRESSION PLATE [J].
FRANKLE, MA ;
CORDEY, J ;
FRANKLE, MD ;
BAUMGART, F ;
PERREN, S .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1994, 8 (01) :59-63