Real-time hybrid model test to replicate high-rise building resonant vibration under wind loads

被引:5
作者
Zhou, Huimeng [1 ,2 ,3 ]
Shao, Xiaoyun [4 ]
Zhang, Jianwen [1 ,2 ,3 ]
Yao, Hongcan [1 ,2 ,3 ]
Liu, Yanhui [1 ,2 ,3 ]
Tan, Pin [1 ,2 ,3 ]
Chen, Yangyang [1 ,2 ,3 ]
Xu, Li [1 ,2 ,3 ]
Zhang, Yin [1 ,2 ,3 ]
Gong, Wei [1 ,2 ,3 ]
机构
[1] Guangzhou Univ, Engn Seism Res Ctr, Guangzhou 510006, Guangdong, Peoples R China
[2] Guangdong Prov Key Lab Earthquake Engn & Appl Tech, Guangzhou 510006, Guangdong, Peoples R China
[3] Minist Educ, Key Lab Earthquake Resistance Earthquake Mitigat &, Guangzhou 510006, Guangdong, Peoples R China
[4] Western Michigan Univ, Kalamazoo, MI 49009 USA
基金
中国国家自然科学基金;
关键词
Real-time hybrid model test; Wind loads; Saige building; Shaking table; Vibration; SYSTEM;
D O I
10.1016/j.tws.2024.111559
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In May 2021, the 72-story Shenzhen Saige building experienced abnormal vibration that was strongly felt on many floors and triggered social panic. The tower was therefore closed for more than 2 months resulting in huge economic losses. A preliminary study consisting of field resonant excitation tests and a series of numerical simulations were carried out. It was concluded that the wind loads provoked the higher modes of the building vibration. Specifically, the vibration of the mast, which is located at the building top, induced this abnormal vibration. To validate this conclusion, real-time hybrid model (RTHM) tests was developed to reproduce this building vibration incident. This paper presents the details of the validation RTHM tests including testing design and result discussions. Structural vibration parameters obtained from the field tests were used in the numerical substructure building model, and the experimental substructures were the two scaled down mast models (the cantilever beam section of the masts). During RTHM test, the restoring force of the experimental substructure due to real wind loads induced by an air fan was measured and used in the numerical simulation to compute interface motions. A shaking table was then used to impose the interface motion back to the bottom of the mast model to reproduce the abnormal vibration incident. The demonstrated ability of the developed RTHM testing method to reproduce the resonant phenomenon of the wind-induced tower vibration provides an alternative experimental method to study vibration responses of high-rise buildings in future.
引用
收藏
页数:12
相关论文
共 34 条
[1]  
Afnor NE, 2010, Amendment 1[S]
[2]   Assessment of wind-induced vibration mitigation in a tall building with damped outriggers using real-time hybrid simulations [J].
Al-Subaihawi, Safwan ;
Kolay, Chinmoy ;
Marullo, Thomas ;
Ricles, James M. ;
Quiel, Spencer E. .
ENGINEERING STRUCTURES, 2020, 205
[3]  
[Anonymous], 2021, Brief Report on Cause Analysis of 518 Building Vibration Event of Shenzhen Saige Square
[4]   Real-time hybrid model testing of floating wind turbines: sensitivity to limited actuation [J].
Bachynski, Erin E. ;
Chabaud, Valentin ;
Sauder, Thomas .
12TH DEEP SEA OFFSHORE WIND R&D CONFERENCE, (EERA DEEPWIND 2015), 2015, 80 :2-12
[5]  
Bachynski Erin E., 2016, P ASME 35 INT C OCEA
[6]  
Berthelsen PA, 2016, PROCEEDINGS OF THE ASME 35TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING , 2016, VOL 6
[7]  
Chopra A.K., 2017, Dynamics of structureS, Theory and applications to earthquake engineering
[8]  
Forouzan B, 2015, 6 INT C ADV EXP STRU
[9]   Hybrid simulation of a structure to tsunami loading [J].
Forouzan, Bahareh ;
Baragamage, Dilshan S. P. Amarsinghe ;
Shaloudegi, Koushyar ;
Nakata, Narutoshi ;
Wu, Weiming .
ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (01) :3-21
[10]  
Horiuchi T, 1999, EARTHQUAKE ENG STRUC, V28, P1121, DOI 10.1002/(SICI)1096-9845(199910)28:10<1121::AID-EQE858>3.3.CO