Rapid and Flexible Humidity Sensor Based on Laser-Induced Graphene for Monitoring Human Respiration

被引:15
作者
Paeng, Changung [1 ]
Shanmugasundaram, Arunkumar [2 ,3 ]
We, Gunwoo [4 ]
Kim, Taewook [1 ,4 ,5 ]
Park, Jongsung [5 ,6 ]
Lee, Dong-Weon [2 ,3 ,7 ]
Yim, Changyong [1 ,4 ,5 ]
机构
[1] Kyungpook Natl Univ KNU, Dept Energy Mat & Chem Engn, Sangju Si 37224, Gyeongsangbuk D, South Korea
[2] Chonnam Natl Univ CNU, Sch Mech Engn, MEMS & Nanotechnol Lab, Gwangju 61186, South Korea
[3] Chonnam Natl Univ CNU, Adv Med Device Res Ctr Cardiovasc Dis, Gwangju 61186, South Korea
[4] Kyungpook Natl Univ KNU, Dept Energy Chem Engn, Sangju Si 37224, Gyeongsangbuk D, South Korea
[5] Kyungpook Natl Univ KNU, Dept Adv Sci & Technol Convergence, Sangju Si 37224, Gyeongsangbuk D, South Korea
[6] Kyungpook Natl Univ KNU, Dept Precis Mech Engn, 2559,Gyeongsang daero, Sangju 37224, Gyeongsangbukdo, South Korea
[7] Chonnam Natl Univ CNU, Ctr Next Generat Sensor Res & Dev, Gwangju 61186, South Korea
基金
新加坡国家研究基金会;
关键词
laser-induced graphene; intense pulsed light sintering; humidity sensing; respiration monitoring; biomedicaldevice; SENSING PROPERTIES; NANOCOMPOSITE; PHOTODETECTOR; POLYIMIDE; COPPER; METER;
D O I
10.1021/acsanm.3c05283
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Respiration is an important physiological parameter used to assess human health and metabolic activity. Herein, we propose a laser-induced graphene (LIG)-based humidity sensor for respiratory monitoring. This sensor is fabricated through a combination of laser irradiation and intense pulsed light (IPL) sintering techniques. Initially, an ink containing copper nanoparticles (CuNPs) and graphene nanoplatelets (GnPs) is coated onto a polyimide (PI) substrate. The LIG is formed on the PI film using laser irradiation. To establish a reliable electrical connection between the LIG and the copper electrode, the ink undergoes rapid IPL sintering, resulting in an IPL-sintered copper electrode. This technique not only optimizes the fabrication process but also obviates the need for traditional approaches, such as copper wire bonding, electrode patterning, or the application of conductive paint on the LIG sensor. The humidity-sensing capabilities of the sensor are assessed under various relative humidity (RH) conditions. The sensor's response escalates from roughly 15 to 92% as RH levels increase from 13 to 67%. The sensor showed minimal response to various potential interfering gases like ammonia, ethanol, carbon monoxide, sulfur dioxide, and nitrogen dioxide (with responses of 0.4, 1.87, 0.102, 0.12, and 0.29%, respectively), confirming its high selectivity for RH (91.2%). Additionally, the sensor demonstrates exemplary reproducibility, as evidenced by its consistent responses (approximately 47.65, 49.13, 48.65, 49.09, and 49.39) over five cycles at 40% RH. The LIG sensor is used to monitor a wide range of respiratory patterns, including normal, slow, fast, and apnea events. The sensor effectiveness is proven through the consistent detection of human breathing patterns over 30 min, demonstrating its stability and reliability for extended use in continuous respiratory monitoring. These findings highlight the significant potential of LIG sensors as advanced precision devices in clinical respiratory monitoring with potential integration into modern medical practices.
引用
收藏
页码:4772 / 4783
页数:12
相关论文
共 61 条
[41]   Toward Point-of-Care chronic disease Management: Biomarker detection in exhaled breath using an E-Nose sensor based on rGO/SnO2 superstructures [J].
Shanmugasundaram, Arunkumar ;
Manorama, Sunkara, V ;
Kim, Dong-Su ;
Jeong, Yun-Jin ;
Lee, Dong Weon .
CHEMICAL ENGINEERING JOURNAL, 2022, 448
[42]   N-/S- dual doped C@ZnO: An excellent material for highly selective and responsive NO2 sensing at ambient temperatures [J].
Shanmugasundaram, Arunkumar ;
Kim, Dong-Su ;
Chinh, Nguyen Duc ;
Park, Jongsung ;
Jeong, Yun-Jin ;
Piao, JunJi ;
Kim, Dojin ;
Lee, Dong Weon .
CHEMICAL ENGINEERING JOURNAL, 2021, 421
[43]   Hierarchical nanohybrids of B- and N- codoped graphene/ mesoporous NiO nanodisks: an exciting new material for selective sensing of H2S at near ambient temperature [J].
Shanmugasundaram, Arunkumar ;
Nguyen Duc Chinh ;
Jeong, Yun-Jin ;
Hou, Tian Feng ;
Kim, Dong-Su ;
Kim, Dojin ;
Kim, Young-Bae ;
Lee, Dong-Weon .
JOURNAL OF MATERIALS CHEMISTRY A, 2019, 7 (15) :9263-9278
[44]   Facile in-situ formation of rGO/ZnO nanocomposite: Photocatalytic remediation of organic pollutants under solar illumination [J].
Shanmugasundaram, Arunkumar ;
Boppella, Ramireddy ;
Jeong, Yun-Jin ;
Park, Jongsung ;
Kim, Young-Bae ;
Choi, Byungchul ;
Park, Su Han ;
Jung, Seunghun ;
Lee, Dong-Weon .
MATERIALS CHEMISTRY AND PHYSICS, 2018, 218 :218-228
[45]   Laser-Induced Graphene for Flexible and Embeddable Gas Sensors [J].
Stanford, Michael G. ;
Yang, Kaichun ;
Chyan, Yieu ;
Kittrell, Carter ;
Tour, James M. .
ACS NANO, 2019, 13 (03) :3474-3482
[46]   Alternative functional criteria to assess airflow-limitation reversibility in asthma [J].
Tavares e Castro, A. ;
Matos, P. ;
Tavares, B. ;
Matos, M. J. ;
Segorbe-Luis, A. .
REVISTA PORTUGUESA DE PNEUMOLOGIA, 2015, 21 (02) :69-75
[47]   Three-Dimensional (3D) Laser-Induced Graphene: Structure, Properties, and Application to Chemical Sensing [J].
Vivaldi, Federico Maria ;
Dallinger, Alexander ;
Bonini, Andrea ;
Poma, Noemi ;
Sembranti, Lorenzo ;
Biagini, Denise ;
Salvo, Pietro ;
Greco, Francesco ;
Di Francesco, Fabio .
ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (26) :30245-30260
[48]   Detection and prevalence of chronic obstructive pulmonary disease in a cardiovascular clinic: Evaluation using a hand held FEV1/FEV6 meter and questionnaire [J].
Wada, Hiroshi ;
Nakano, Yasutaka ;
Nagao, Taishi ;
Osawa, Makoto ;
Yamada, Hideto ;
Sakaguchi, Chikara ;
Matsumoto, Tetsuya ;
Tsutamoto, Takayoshi ;
Ito, Makoto ;
Horie, Minoru .
RESPIROLOGY, 2010, 15 (08) :1252-1258
[49]   Laser-induced graphene: preparation, functionalization and applications [J].
Wang, Fangcheng ;
Wang, Kedian ;
Zheng, Buxiang ;
Dong, Xia ;
Mei, Xuesong ;
Lv, Jing ;
Duan, Wenqiang ;
Wang, Wenjun .
MATERIALS TECHNOLOGY, 2018, 33 (05) :340-356
[50]   High-Sensitivity Wearable and Flexible Humidity Sensor Based on Graphene Oxide/Non-Woven Fabric for Respiration Monitoring [J].
Wang, Yamei ;
Zhang, Liwen ;
Zhang, Zhenwei ;
Sun, Pengyuan ;
Chen, Huawei .
LANGMUIR, 2020, 36 (32) :9443-9448