Analysis and Experimental Verification of the EMI Signature of Three-Phase Three-Level TCM Soft-Switching Converter Systems

被引:1
|
作者
Miric, Spasoje [1 ]
Niklaus, Pascal S. [2 ]
Huber, Jonas [2 ]
Stager, Christof [2 ]
Haider, Michael [2 ]
Kolar, Johann W. [2 ]
机构
[1] Univ Innsbruck, Innsbruck Drive & Energy Syst Lab, A-6020 Innsbruck, Austria
[2] Swiss Fed Inst Technol, Power Elect Syst Lab, CH-8092 Zurich, Switzerland
关键词
Electromagnetic interference; Power harmonic filters; Inverters; Switches; Zero voltage switching; Capacitance; Switching frequency; Electromagnetic interference (EMI); triangular current mode (TCM); inverter; dc-to-ac converter; soft switching; zero voltage switching (ZVS); MODULATION;
D O I
10.1109/ACCESS.2023.3283921
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper investigates the Electromagnetic Interference (EMI) noise signature of three-phase three-level (3L) Triangular Current Mode (TCM)-modulated grid-tied Photovoltaic (PV) inverters that achieve full Zero Voltage Switching (ZVS) and thus minimal switching losses over the entire mains period and/or ensure > 99 % efficiency. Further required is a very high power density, which facilitates installation and is achieved with high switching frequencies > 100 kHz. The impact of the characteristic variation of f(sw) in all three phases and the therefore different instantaneous switching frequencies in each phase on the overall converter EMI noise signature is analyzed and it is found that the consideration of only one single phase is sufficient to characterize the noise emissions. Numeric approaches to estimate the detector output of EMI test receivers are compared and it turns out that the peak value of the noise voltage envelope is a useful measure to determine the required filter attenuation, provided the phase-shift of the harmonics is considered in the envelope detection. Finally, a hardware demonstrator of a 6.6 kW, > 99% efficiency three-phase 3L-TCM PV inverter with a power density of 6.2 kW/dm(3) (102 W/in(3)) is designed and the theoretical findings are verified. Moreover, the impact of parasitic capacitances from the switch-nodes and from the floating dc link to Protective Earth (PE) is thoroughly studied qualitatively and quantitatively with the result that these capacitances considerably reduce filter attenuation (35 dB at 150 kHz in the case at hand), requiring sufficient design margin.
引用
收藏
页码:57391 / 57400
页数:10
相关论文
共 50 条
  • [21] Three-Phase Single-Stage Bidirectional CCM Soft-Switching ACDC Converter With Minimum Switch Count
    Lee, Jaeyeon
    Jeong, Hyeonju
    Le, Tat-Thang
    Choi, Sewan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (02) : 2052 - 2062
  • [22] OSAKA Converter - Large scale three-phase soft-switching power factor corrected converter
    Taniguchi, K
    Morizane, T
    Kimura, N
    Ogawa, M
    IPEMC 2004: THE 4TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2004, : 913 - 918
  • [23] Three-Phase Soft-Switching Inverter With Minimum Components
    Amini, Mohammad Reza
    Farzanehfard, Hosein
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (06) : 2258 - 2264
  • [24] A Simplified Resonant Pole for Three-Level Soft-Switching PFC Rectifier Used in UPS
    Rizet, Corentin
    Ferrieux, Jean-Paul
    Le Moigne, Philippe
    Delarue, Philippe
    Lacarnoy, Alain
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (08) : 2739 - 2746
  • [25] A three-phase three-level converter with shared flying capacitors
    Pain, Maxime
    Gateau, Guillaume
    Blaquiere, Jean-Marc
    IET POWER ELECTRONICS, 2023,
  • [26] Soft-Switching Bidirectional Three-Level DC-DC Converter with Simple Auxiliary Circuit
    Choi, Woo-Young
    Yang, Min-Kwon
    ELECTRONICS, 2019, 8 (09)
  • [27] Three-phase Current-fed Soft-switching DC-DC Converter
    Suryadevara, Rohit
    Li, Tao
    Modepalli, Kumar
    Parsa, Leila
    2017 IEEE 26TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2017, : 899 - 904
  • [28] Novel Three-Phase Resonant Pole Inverter with Soft-Switching Function
    Wang Q.
    Cao R.
    Wang T.-S.
    Liu X.-Q.
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2022, 50 (05): : 1277 - 1280
  • [29] Three-Phase Resonant DC Link Inverter with Soft-Switching Function
    Wang Q.
    Guo G.-X.
    Wang T.-S.
    Liu X.-Q.
    Tien Tzu Hsueh Pao/Acta Electronica Sinica, 2019, 47 (09): : 1994 - 1997
  • [30] The three-phase resonant DC link inverter with soft-switching function
    Wang, Qiang
    Guo, Guoxian
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2020, 107 (08) : 1324 - 1344