Chromium measurement in pharmaceutical samples: a comparative study of three new membrane electrodes with different electron-ion exchangers

被引:0
作者
Vazifekhoran, Parviz Ebadi [1 ]
Hajiaghababaei, Leila [1 ]
Ghasri, Mohammad Reza Allahgholi [1 ]
Shahvelayati, Ashraf Sadat [1 ]
Kalateh, Khadijeh [1 ]
机构
[1] Islamic Azad Univ, Dept Chem, Yadegar e Imam Khomeini RAH Shahre Rey Branch, Tehran, Iran
关键词
Compendex;
D O I
10.1039/d2ay01601j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present study deals with synthesis of N-(thiazol-2-ylcarbamothioyl) benzamide. It was utilized as a neutral ionophore for designing three types of chromium(iii) sensors including coated wire ion selective electrodes (CW-ISEs), ion selective electrodes with liquid internal electrolyte (LIE-ISEs), and solid-state ion selective electrodes (SS-ISEs). UV-visible spectrophotometry was used to confirm the affinity of N-(thiazol-2-ylcarbamothioyl) benzamide to chromium(iii). It was found that a membrane with a composition of 2% NaTPB, 8% ionophore, 60% DBP, and 30% PVC showed the best performance and a Nernstian slope of 21.6 mV per decade. Scanning electron microscopy was used to assess the PVC membrane morphology. The existence of chromium(iii) in the liquid membrane matrix was proved by energy-dispersive X-ray spectroscopy. Detection limits for SS-ISE (1 x 10(-6) M) and CW-ISE (1 x 10(-6) M) were enhanced relative to LIE-ISE (1 x 10(-5) M). All three electrodes showed a response time of about 5 s. The sensors' applicable pH range was 4.0-6.0. Fourier transform infrared spectra recorded through the electrode membrane showed that chromium(iii) ion can interact with sulfur, nitrogen and oxygen atoms of N-(thiazol-2-ylcarbamothioyl) benzamide. The sensors were utilized as indicator electrodes in chromium(iii) potentiometric titration with ethylenediaminetetraacetic acid and for directly measuring chromium(iii) in some pharmaceutical samples.
引用
收藏
页码:1431 / 1440
页数:10
相关论文
共 48 条
  • [1] Carbon composite-PVC based membrane coated platinum electrode for chromium determination
    Abbaspour, A.
    Refahi, M.
    Khalafi-Nezhad, A.
    Rad, N. Soltani
    Behrouz, S.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2010, 184 (1-3) : 20 - 25
  • [2] Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene
    Abbaspour, A
    Izadyar, A
    [J]. TALANTA, 2001, 53 (05) : 1009 - 1013
  • [3] Comparative Study of Carbon Paste, Screen Printed, and PVC Potentiometric Sensors Based on Copper-sulphamethazine Schiff Base Complex for Determination of Iodide - Experimental and Theoretical Approaches
    Abdel-Haleem, F. M.
    Shehab, Ola R.
    [J]. ELECTROANALYSIS, 2016, 28 (04) : 800 - 807
  • [4] Cr(III) ion-selective membrane sensor based on 1,3-Diamino-2-hydroxypropane-N,N,N',N'- tetraacetic acid
    Abedi, Mohammad Reza
    Zamani, Hassan Ali
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    [J]. SENSOR LETTERS, 2007, 5 (3-4) : 516 - 521
  • [5] DETERMINATION OF CHROMIUM OXIDATION-STATE BY X-RAY-FLUORESCENCE SPECTROMETRY - APPLICATION TO CHROMIUM(VI) AND CHROMIUM(III) DETERMINATION IN OCCUPATIONAL HYGIENE SAMPLES
    ARBER, JM
    URCH, DS
    WEST, NG
    [J]. ANALYST, 1988, 113 (05) : 779 - 782
  • [6] Selective determination of Cr(III) by modified carbon nanotube paste electrode: a potentiometric study
    Barati, Zahra
    Masrournia, Mahboubeh
    Es'haghi, Zarrin
    Jahani, Moslem
    Ebrahimi, Javad
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2022, 97 (05) : 1234 - 1239
  • [7] Pramipexole Symmetric and Asymmetric Potentiometric PVC Membrane Sensors
    Faridbod, Farnoush
    Jamshidpour, Tahereh
    Ganjali, Mohammad Reza
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (09): : 7990 - 8001
  • [8] Application of carbon sensors for potentiometric determination of copper(II) in water and biological fluids of Wilson disease patients. Studying the surface reaction using SEM, EDX, IR and DFT
    Frag, Eman Yossri
    Mohamed, Marwa El Badry
    Fahim, Elham M.
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 118 : 122 - 128
  • [9] Highly selective and sensitive chromium(III) membrane sensors based on a new tridentate Schiff's base
    Ganjali, Mohammad Reza
    Norouzi, P.
    Faridbod, F.
    Ghorbani, M.
    Adib, M.
    [J]. ANALYTICA CHIMICA ACTA, 2006, 569 (1-2) : 35 - 41
  • [10] Preparation of a new chromium(III) selective electrode based on 1-[(2-hydroxy ethyl) amino]-4-methyl-9H-thioxanthen-9-one as a neutral carrier
    Ghaedi, M.
    Shokrollahi, A.
    Salimibeni, A. R.
    Noshadi, S.
    Joybar, S.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2010, 178 (1-3) : 157 - 163