Integration of reconfigurable fault-tolerant three-level inverter in photovoltaic power system

被引:1
作者
Benaouda, Omar Fethi [1 ]
Kahla, Sami [1 ]
Bouchakour, Mohamed [2 ]
Bendiabdellah, Azzedine [3 ]
机构
[1] Res Ctr Ind Technol CRTI, Algiers, Algeria
[2] Univ Djelfa, Fac Exact Sci & Informat, Dept Phys, PCME Lab, Djelfa, Algeria
[3] Univ Sci & Technol Oran MB, Fac Elect Engn, LDEE Lab, Diagnost Grp, Oran, Algeria
关键词
PV array; Multi-level inverter; IGBT; Open-circuit faults; diagnosis; DT-TC; Fault-tolerant; reconfigurable; DC-DC CONVERTER; OPEN-SWITCH FAULT; TOPOLOGIES; DIAGNOSIS; MPPT;
D O I
10.1080/02286203.2023.2165786
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A lot of previous studies have shown a great interest in connecting photovoltaic (PV) arrays to electric power grids. A Maximum Power Point Tracker (MPPT) controlled 100 kW PV array to boost its power that feeds the grid with the help of a three-level inverter. This paper investigated the effects of open-circuit faults of three-level inverter IGBT switches on the performance of the PV array system. This paper proposes a new diagnostic method called the Double Threshold-Trigonometric Coordinates (DT-TC) that relies on the double threshold technique and the trigonometric coordinates, respectively, for early detection and the precise location of open-circuit faults. To the best knowledge of the authors, two simultaneous open-circuit faults were not considered in the previous studies. The obtained simulation results prove the great success of the proposed diagnosis method even under noticeable changes in irradiation, temperature, and the number of PV array connected in series and in parallel. In this study, the reconfigurable fault-tolerant inverter was included to ensure the perfect continuity of the PV array system and its recovery in an extremely very short time up to 7 ms.
引用
收藏
页码:212 / 231
页数:20
相关论文
共 51 条
[1]  
Abadi MB, 2012, 2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), P1893, DOI 10.1109/ICElMach.2012.6350140
[2]  
Al-Gizi A, 2017, 2017 INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT (OPTIM) & 2017 INTL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS (ACEMP), P642, DOI 10.1109/OPTIM.2017.7975041
[3]   Modified efficient perturb and observe maximum power point tracking technique for grid-tied PV system [J].
Ali, Ahmed I. M. ;
Sayed, Mahmoud A. ;
Mohamed, Essam E. M. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 99 :192-202
[4]  
[Anonymous], 2016, International Review on Modelling and Simulations (IREMOS)
[5]  
Anowar M.H., 2019, P 2019 INT C EL COMP, P1, DOI DOI 10.1109/ECACE.2019.8679308
[6]   Integrated DC-DC Converter Based Grid-Connected Transformerless Photovoltaic Inverter With Extended Input Voltage Range [J].
Anurag, Anup ;
Deshmukh, Nachiketa ;
Maguluri, Avinash ;
Anand, Sandeep .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (10) :8322-8330
[7]   A Novel Fault-Tolerant Technique for Active-Neutral-Point-Clamped Inverter Using Carrier-Based PWM [J].
Azer, Peter ;
Ouni, Saeed ;
Narimani, Mehdi .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (03) :1792-1803
[8]  
Badis A., 2017, INT C ENG MIS ICEMIS, P1
[9]   Modeling and Fuzzy MPPT Controller Design for Photovoltaic Module Equipped with a Closed-Loop Cooling System [J].
Bechouat, M. ;
Sedraoui, M. ;
Feraga, C. -E. ;
Aidoud, M. ;
Kahla, S. .
JOURNAL OF ELECTRONIC MATERIALS, 2019, 48 (09) :5471-5480
[10]   Fault tolerance performance of dual-inverter-based six-phase drive system under single-, two-, and three-phase open-circuit fault operation [J].
Bezerra Melo, Victor Felipe Moura ;
Jacobina, Cursino Brandao ;
Rocha, Nady .
IET POWER ELECTRONICS, 2018, 11 (01) :212-220