Effects of indoor low humidity on eye discomfort and associated physiological responses in soft contact lens and non-lens wearers

被引:3
作者
Ito, Kanoko [1 ]
Takada, Satoru [1 ]
机构
[1] Kobe Univ, Grad Sch Engn, Dept Architecture, Kobe, Hyogo, Japan
关键词
Indoor environment; humidity comfort; dry eye; tear film; ocular surface temperature; blink pattern; TEAR FILM INSTABILITY; OCULAR SURFACE; DRY EYE; ENVIRONMENTAL-QUALITY; RELATIVE-HUMIDITY; THERMAL COMFORT; BLINK RATE; DYNAMICS; TEMPERATURE; SYMPTOMS;
D O I
10.1177/1420326X221126352
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Eye discomfort due to dryness is one of the major complaints reported in indoor spaces. The purpose of this study was to quantitatively evaluate the effect of low humidity on eye discomfort in soft contact lens (SCL) and non-CL wearers. In addition to subjective sensations, physiological parameters related to eye discomfort including tear-film parameters and blink patterns were comparatively evaluated between relative humidities of 10% and 45% at 23 degrees C. For both the SCL and non-CL wearer groups, low humidity had a significant effect on some of the measured physiological parameters. The SCL group showed lower ocular surface temperature and larger temperature differential after blinking at 10% relative humidity (RH) than that at 45% RH, indicating faster tear evaporation. Furthermore, their tear films tended to be thinner and have a shorter break-up time at 10% RH than at 45% RH. The non-CL group showed a significantly higher blink frequency and longer eye-closure time at 10% RH than at 45% RH, presumably as a compensatory response to the disturbance of the tear film due to low humidity. These results suggest the importance of humidity control in indoor spaces in terms of tear-film quality, which contributes to eye discomfort.
引用
收藏
页码:590 / 602
页数:13
相关论文
共 68 条
[41]   Reliability and efficacy of maximum fluorescein tear break-up time in diagnosing dry eye disease [J].
Mou, Yujie ;
Xiang, Huan ;
Lin, Lin ;
Yuan, Kelan ;
Wang, Xin ;
Wu, Yaying ;
Min, Jinjin ;
Jin, Xiuming .
SCIENTIFIC REPORTS, 2021, 11 (01)
[42]   The relation between physical properties of the anterior eye and ocular surface temperature [J].
Purslow, Christine ;
Wolffsohn, James .
OPTOMETRY AND VISION SCIENCE, 2007, 84 (03) :197-201
[43]   Indoor temperature and humidity in New York City apartments during winter [J].
Quinn, Ashlinn ;
Shaman, Jeffrey .
SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 583 :29-35
[44]   Reliability and validity of the ocular surface disease index [J].
Schiffman, RM ;
Christianson, MD ;
Jacobsen, G ;
Hirsch, JD ;
Reis, BL .
ARCHIVES OF OPHTHALMOLOGY, 2000, 118 (05) :615-621
[45]   Comparing mixing and displacement ventilation in tutorial rooms: Students' thermal comfort, sick building syndromes, and short-term performance [J].
Shan, Xin ;
Zhou, Jin ;
Chang, Victor W. -C. ;
Yang, En-Hua .
BUILDING AND ENVIRONMENT, 2016, 102 :128-137
[46]   Effects of Tear Film Instability on Sensory Responses to Corneal Cold, Mechanical, and Chemical Stimuli [J].
Situ, Ping ;
Begley, Carolyn G. ;
Simpson, Trefford L. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (08) :2935-2941
[47]   Apparent time-dependent differences in inferior tear meniscus height in human subjects with mild dry eye symptoms [J].
Srinivasan, Sruthi ;
Chan, Colin ;
Jones, Lyndon .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2007, 90 (05) :345-350
[48]  
Sundell J., 1993, INDOOR AIR, V3, P382
[49]  
Sunwoo Yujin, 2006, Journal of Physiological Anthropology and Applied Human Science, V25, P7, DOI 10.2114/jpa2.25.7
[50]  
Sunwoo Yujin, 2006, Journal of Physiological Anthropology, V25, P229, DOI 10.2114/jpa2.25.229