Temporal relationship between haemodynamic changes and activation of closed-loop stimulation during a tilt-induced vasovagal syncope

被引:4
作者
Russo, Vincenzo [1 ]
Tomaino, Marco [2 ]
Parente, Erika [1 ]
Comune, Angelo [1 ]
Giacopelli, Daniele [3 ]
Napoli, Paola [3 ]
Gargaro, Alessio [3 ]
Brignole, Michele [4 ]
机构
[1] Univ Campania, Luigi Vanvitelli Monaldi Hosp, Dept Translat Med Sci, Cardiol & Syncope Unit, I-80126 Naples, Italy
[2] Osped Gen Reg, Dept Cardiol, Bolzano, Italy
[3] Res Clin Unit, Biotron Italy, Milan, Italy
[4] S Luca Hosp, IRCCS Ist Auxol Italiano, Faint & Fall Res Ctr, Dept Cardiol, Piazzale Brescia 20, I-20149 Milan, Italy
来源
EUROPACE | 2024年 / 26卷 / 02期
关键词
Vasovagal syncope; Tilt table test; Pacemaker therapy; Close-loop stimulation; RECURRENT REFLEX SYNCOPE; INTRACARDIAC IMPEDANCE; HEART-RATE;
D O I
10.1093/europace/euae045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims A dual-chamber pacemaker with closed-loop stimulation (CLS) mode is effective in reducing syncopal recurrences in patients with asystolic vasovagal syncope (VVS). In this study, we explored the haemodynamic and temporal relationship of CLS during a tilt-induced vasovagal reflex.Methods and results Twenty patients underwent a tilt test under video recording 3.9 years after CLS pacemaker implantation. Three patients were excluded from the analysis because of no VVS induced by the tilt test (n = 1) and protocol violation (n = 2). In 14 of the remaining 17 patients, CLS pacing emerged during the pre-syncopal phase of circulatory instability when the mean intrinsic heart rate (HR) was 88 +/- 12 b.p.m. and systolic blood pressure (SBP) was 108 +/- 19 mmHg. The CLS pacing rate thereafter rapidly increased to 105 +/- 14 b.p.m. within a median of 0.1 min [inter-quartile range (IQR), 0.1-0.7 min] when the SBP was 99 +/- 21 mmHg. At the time of maximum vasovagal effect (syncope or pre-syncope), SBP was 63 +/- 17 mmHg and the CLS rate was 95 +/- 13 b.p.m. The onset of CLS pacing was 1.7 min (IQR, 1.5-3.4) before syncope or lowest SBP. The total duration of CLS pacing was 5.0 min (IQR, 3.3-8.3). Closed-loop stimulation pacing was not observed in three patients who had a similar SBP decrease from 142 +/- 22 mmHg at baseline to 69 +/- 4 mmHg at the time of maximum vasovagal effect, but there was no significant increase in HR (59 +/- 1 b.p.m.).Conclusion The reproducibility of a vasovagal reflex was high. High-rate CLS pacing was observed early during the pre-syncopal phase in most patients and persisted, although attenuated, at the time of maximum vasovagal effect.Registration ClinicalTrials.gov identifier: NCT06038708 Graphical Abstract
引用
收藏
页数:8
相关论文
共 24 条
  • [1] Impact of dual-chamber pacing with closed loop stimulation on quality of life in patients with recurrent reflex vasovagal syncope: results of the SPAIN study
    Baron-Esquivias, Gonzalo
    Moya-Mitjans, Angel
    Martinez-Alday, Jesus
    Ruiz-Granell, Ricardo
    Lacunza-Ruiz, Javier
    Garcia-Civera, Roberto
    Gutierrez-Carretero, Encarnacion
    Romero-Garrido, Rafael
    Morillo, Carlos A.
    [J]. EUROPACE, 2020, 22 (02): : 314 - 319
  • [2] Dual-Chamber Pacing With Closed Loop Stimulation in Recurrent Reflex Vasovagal Syncope The SPAIN Study
    Baron-Esquivias, Gonzalo
    Morino, Carlos A.
    Moya-Mitjans, Angel
    Martinez-Alday, Jesus
    Ruiz-Granell, Ricardo
    Lacunza-Ruiz, Javier
    Garcia-Civera, Roberto
    Gutierrez-Carretero, Encarnacion
    Romero-Garrido, Rafael
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (14) : 1720 - 1728
  • [3] 'The Italian Protocol': a simplified head-up tilt testing potentiated with oral nitroglycerin to assess patients with unexplained syncope
    Bartoletti, A
    Alboni, P
    Ammirati, F
    Brignole, M
    Del Rosso, A
    Manzillo, GF
    Menozzi, C
    Raviele, A
    Sutton, R
    [J]. EUROPACE, 2000, 2 (04): : 339 - 342
  • [4] Autonomic nervous system-controlled cardiac pacing:: A comparison between intracardiac impedance signal and muscle sympathetic nerve activity
    Binggeli, C
    Duru, F
    Corti, R
    Sudano, I
    Spieker, LE
    Turina, A
    Westermann, P
    Ostermeier, M
    Rahn, M
    Lüscher, TF
    Noll, G
    Candinas, R
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1632 - 1637
  • [5] Non-invasive assessment of myocardial contractility from force-frequency relationship in patients with implanted pacemakers: first results
    Bondke, Hansjuergen
    Borges, Adrian-Constantin
    Petersen, Sven
    Walde, Thomas
    Baumann, Gert
    [J]. EUROPACE, 2010, 12 (07): : 968 - 971
  • [6] Cardiac pacing in severe recurrent reflex syncope and tilt-induced asystole
    Brignole, Michele
    Russo, Vincenzo
    Arabia, Francesco
    Oliveira, Mario
    Pedrote, Alonso
    Aerts, Arnaud
    Rapacciuolo, Antonio
    Boveda, Serge
    Deharo, Jean Claude
    Maglia, Giampiero
    Nigro, Gerardo
    Giacopelli, Daniele
    Gargaro, Alessio
    Tomaino, Marco
    [J]. EUROPEAN HEART JOURNAL, 2021, 42 (05) : 508 - 516
  • [7] Enhancement of bicycle exercise capacity in patients with chronotropic incompetence through closed-loop stimulation: a randomized crossover trial
    Chua, Su-Kiat
    Chen, Wen-Ling
    Chen, Lung-Ching
    Shyu, Kou-Gi
    Hung, Huei-Fong
    Lee, Shih-Huang
    Wang, Tzu-Lin
    Lai, Wei-Ting
    Chen, Kuan-Jen
    Liao, Zhen-Yu
    Chuang, Cheng-Yen
    Chou, Ching-Yao
    [J]. EUROPACE, 2023, 25 (12):
  • [8] A novel and practical method to add video monitoring to tilt table testing
    de Lange, Frederik Jorrit
    Hofland, Willem Petrus Merijn Emmanuel
    Ferrara, Alessio
    Gargaro, Alessio
    Brignole, Michele
    van Dijk, Jan Gerrit
    [J]. EUROPACE, 2023, 25 (02): : 762 - 766
  • [9] The pathophysiology of the vasovagal response
    Jardine, David L.
    Wieling, Wouter
    Brignole, Michele
    Lenders, Jacques W. M.
    Sutton, Richard
    Stewart, Julian
    [J]. HEART RHYTHM, 2018, 15 (06) : 921 - 929
  • [10] Closed-loop stimulation using intracardiac impedance as a sensor principle:: Correlation of right ventricular dP/dtmax and intracardiac impedance during dobutamine stress test
    Osswald, S
    Cron, T
    Grädel, C
    Hilti, P
    Lippert, M
    Ströbel, J
    Schaldach, M
    Buser, P
    Pfisterer, M
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (10): : 1502 - 1508