Compact methane sensor using an integrating sphere and interband cascade laser at 3313 nm

被引:13
作者
Davis, Nicholas M. [1 ]
Francis, Daniel [1 ]
Hodgkinson, Jane [1 ]
Tatam, Ralph P. [1 ]
机构
[1] Cranfield Univ, Engn Photon, Cranfield MK43 0AL, England
基金
英国工程与自然科学研究理事会;
关键词
Integrating sphere; Gas detection; Interband cascade laser; Atmospheric methane; Tunable diode laser absorption spectroscopy; TDLAS; ABSORPTION CELLS; SPECTROSCOPY; TEMPERATURE; ETHANE; PATHS; NOISE;
D O I
10.1016/j.snb.2023.133866
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a sensor for gas detection utilising an integrating sphere and interband cascade laser for tunable diode laser absorption spectroscopy (TDLAS). Measurements were made of the methane absorption line at 3313 nm using an integrating sphere with an effective pathlength of 70.1 cm. Gas concentrations were estimated from normalised absorption spectra with line fitting to 7 absorption lines within the scan. Testing showed that measurements were linear for methane in synthetic air for concentrations in the range 0-50 ppm. With an averaging time of 20 s, the noise-equivalent methane concentration was 180 ppb (1 & sigma;). The system requires minimal alignment, with preliminary measurements indicating the system is insensitive to vibration and misalignment of the laser input. The lack of alignment optics also allows it to be compact (190x170x120mm) and robust.
引用
收藏
页数:8
相关论文
共 50 条
[41]   Development of a spectral response calibration system using a wave length-tunable laser and an integrating sphere [J].
Yasuji, Y .
SICE 2002: PROCEEDINGS OF THE 41ST SICE ANNUAL CONFERENCE, VOLS 1-5, 2002, :2082-2087
[42]   Highly sensitive QEPAS sensor for sub-ppb N2O detection using a compact butterfly-packaged quantum cascade laser [J].
Yang, Min ;
Wang, Zhen ;
Sun, Haojia ;
Hu, Mengyuan ;
Yeung, Pak To ;
Nie, Qinxue ;
Liu, Shanliang ;
Akikusa, Naota ;
Ren, Wei .
APPLIED PHYSICS B-LASERS AND OPTICS, 2024, 130 (01)
[43]   A trace gas sensor using near infrared distributed feedback laser at 1654 nm [J].
Li, Bin ;
He, Qi-Xin ;
Liu, Hui-Fang ;
Wang, Yi-Ding .
LASER PHYSICS, 2015, 25 (08)
[44]   Development of a Sub-ppb Resolution Methane Sensor Using a GaSb-Based DFB Diode Laser near 3270 nm for Fugitive Emission Measurement [J].
Oliaee, Jalal Norooz ;
Sabourin, Nicaulas A. ;
Festa-Bianchet, Simon A. ;
Gupta, James A. ;
Johnson, Matthew R. ;
Thomson, Kevin A. ;
Smallwood, Greg J. ;
Lobo, Prem .
ACS SENSORS, 2022, 7 (02) :564-572
[45]   Compact carbon dioxide sensor using tunable diode laser absorption spectroscopy for capnographic monitoring [J].
Li, Jinyi ;
Cheng, Xinyu ;
Tian, Xinli ;
Zhao, Hang ;
Li, Lianhui .
SPECTROSCOPY LETTERS, 2022, 55 (03) :183-191
[46]   Assessing firmness and SSC of pears based on absorption and scattering properties using an automatic integrating sphere system from 400 to 1150 nm [J].
He, Xueming ;
Fu, Xiaping ;
Rao, Xiuqin ;
Fang, Zhenhuan .
POSTHARVEST BIOLOGY AND TECHNOLOGY, 2016, 121 :62-70
[47]   Design and performance of a sensor system for detection of multiple chemicals using an external cavity quantum cascade laser [J].
Phillips, Mark C. ;
Taubman, Matthew S. ;
Bernacki, Bruce E. ;
Cannon, Bret D. ;
Schiffern, John T. ;
Myers, Tanya L. .
QUANTUM SENSING AND NANOPHOTONIC DEVICES VII, 2010, 7608
[48]   Determining the optical properties of blood using He-Ne laser and double integrating sphere set-up [J].
Ashoor, Habib E. ;
Jasim, Khalil Ebrahim .
POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2019, 25 (01) :1-5
[49]   Simultaneous detection of ambient methane, nitrous oxide, and water vapor using an external-cavity quantum cascade laser [J].
Cui, Xiaojuan ;
Dong, Fengzhong ;
Zhang, Zhirong ;
Sun, Pengshuai ;
Xia, Hua ;
Fertein, Eric ;
Chen, Weidong .
ATMOSPHERIC ENVIRONMENT, 2018, 189 :125-132
[50]   Ppb-level formaldehyde detection using a CW room-temperature interband cascade laser and a miniature dense pattern multipass gas cell [J].
Dong, Lei ;
Yu, Yajun ;
Li, Chunguang ;
So, Stephen ;
Tittel, Frank K. .
OPTICS EXPRESS, 2015, 23 (15) :19821-19830