Ventilatory threshold concordance between ergoespirometry and heart rate variability in female professional cyclists

被引:1
作者
Mina-Paz, Yecid [1 ,2 ]
Javier Tafur-Tascon, Luis [1 ]
Arturo Cabrera-Hernandez, Moises [1 ]
Povea-Combariza, Camilo [3 ]
Tejada, Ximena [1 ]
Hurtado-Gutierrez, Hugo [4 ]
Andres Garcia-Corzo, Sergio [1 ]
Garcia-Vallejo, Felipe [2 ]
机构
[1] Univ Inst Natl Sports Sch, Fac Educ & Sports Sci, Res Grp Appl Studies Sport, Cali, Colombia
[2] Univ Valle, Mol Biol & Pathogenesis Res Grp, Dept Physiol Sci, Sch Basic Sci,Fac Hlth, Cali, Colombia
[3] Natl Univ, Fac Hlth, Bogota, Colombia
[4] Catholic Univ, Fac Hlth, Fdn Lumen Gentium, Cali, Colombia
来源
JOURNAL OF HUMAN SPORT AND EXERCISE | 2023年 / 18卷 / 01期
关键词
Ventilatory threshold; Ergospirometry; Heart rate variability; Cyclists; Women; RESPIRATORY SINUS ARRHYTHMIA; VALIDITY;
D O I
10.14198/jhse.2023.181.01
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The ventilatory threshold (VT) is the point at which ventilation intensifies disproportionately concerning to the oxygen uptake, this parameter is essential within the training methodology to optimize performance; the purpose of this work is to measure the degree of agreement between the determination of the ventilatory threshold determined by for oxygen uptake and four methods by Heart Rate Variability (HRV). Methodology: Twelve professional female cyclists between 18 and 28 years of age were evaluated through a maximal incremental test on a cycle ergometer; gas exchange was measure with a portable telemetric device (Cosmed K4b2 (R)) and simultaneously the HRV was registered by R-R recording trough a Polar RS800CX (R) (Polar, Finland) heart rate monitor. Statistics: The degree of precision and accuracy established between the variables mentioned and normality test Shapiro-Wilk. Results: rho = 1.00 with p-value <.05, and Lin correlation and concordance coefficients of .99 with r = 0.98 for ventilatory threshold 2 (VT2), constituting a level of precision and accuracy almost perfect; by contrast, ventilatory threshold 1 (VT1) did not show significant precision and accuracy. This study suggests that VT2 can be identified from The time series. RR using the analysis of frequency and temporal domains likewise allows. Us to have a reference measure for future research in other sports.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 32 条
[1]   High-frequency oscillations of the heart rate during ramp load reflect the human anaerobic threshold [J].
Anosov, O ;
Patzak, A ;
Kononovich, Y ;
Persson, PB .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 83 (4-5) :388-394
[2]   Physical Activity and Concordance between Objective and Perceived Walkability [J].
Arvidsson, Daniel ;
Kawakami, Naomi ;
Ohlsson, Henrik ;
Sundquist, Kristina .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 (02) :280-287
[3]   Influences of breathing patterns on respiratory sinus arrhythmia in humans during exercise [J].
Blain, G ;
Meste, O ;
Bermon, S .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2005, 288 (02) :H887-H895
[4]  
Boron W, 2015, FISIOLOGIA MED
[5]   Yo-Yo intermittent recovery test level 2: Cardiorespiratory response and performance in professional soccer players, comparison between under 20 and over 20 years old players [J].
Cabrera Hernandez, Moises Arturo ;
Tafur Tascon, Luis Javier ;
Andres Garcia-Corzo, Sergio ;
Arias Londono, Hernando ;
Quinones Sanchez, Alexander ;
Carreno Cano, Gina ;
Hurtado Gutierrez, Hugo ;
Tejada Rojas, Carmen Ximena .
JOURNAL OF HUMAN SPORT AND EXERCISE, 2018, 13 :S351-S362
[6]  
Cabrera-Hernandez M.A., 2018, Journal of Human Sport and Exercise, V13, pS401, DOI [10.14198/jhse.2018.13.Proc2.24, DOI 10.14198/JHSE.2018.13.PROC2.24]
[7]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[8]   Ventilatory thresholds assessment from heart rate variability during an incremental exhaustive running test [J].
Cottin, F. ;
Medigue, C. ;
Lopes, P. ;
Lepretre, P.-M. ;
Heubert, R. ;
Billat, V. .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2007, 28 (04) :287-294
[9]   Heart rate variability during exercise performed below and above Ventilatory threshold [J].
Cottin, FO ;
Médigue, C ;
Leprétre, PM ;
Papelier, Y ;
Koralsztein, JP ;
Billat, V .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (04) :594-600
[10]   Reliability and validity of heart rate variability threshold assessment during an incremental shuttle-walk test in middle-aged and older adults [J].
Dourado, V. Z. ;
Guerra, R. L. F. .
BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2013, 46 (02) :194-199