Clinical challenges of biomechanical performance of narrow-diameter implants in maxillary posterior teeth in aging patients: A finite element analysis

被引:1
作者
Prasitwuttisak, Saranyoo [1 ]
Chantarapanich, Nattapon [2 ]
Apinyauppatham, Komsan [1 ]
Poomparnich, Kopchai [1 ]
Inglam, Samroeng [1 ]
机构
[1] Thammasat Univ, Fac Dent, Pathum Thani, Thailand
[2] Kasetsart Univ, Fac Engn Sriracha, Dept Mech Engn, Chon Buri, Thailand
关键词
STRESS-DISTRIBUTION; DENTAL IMPLANTS; ALL-ON-4; TREATMENT; SURVIVAL; SUCCESS;
D O I
10.1371/journal.pone.0299816
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study evaluated the biomechanical performance of narrow-diameter implant (NDI) treatment in atrophic maxillary posterior teeth in aging patients by finite element analysis. The upper left posterior bone segment with first and second premolar teeth missing obtained from a patient's cone beam computed tomography data was simulated with cortical bone thicknesses of 0.5 and 1.0 mm. Three model groups were analyzed. The Regimen group had NDIs of 3.3 x 10 mm in length with non-splinted crowns. Experimental-1 group had NDIs of 3.0 x 10 mm in length with non-splinted crowns and Experimental-2 group had NDIs of 3.0 x 10 mm in length with splinted crowns. The applied load was 56.9 N in three directions: axial (along the implant axis), oblique at 30 degrees (30 degrees to the bucco-palatal plane compared to the vertical axis of the tooth), and lateral load at 90 degrees (90 degrees in the bucco-palatal plane compared to the vertical axis of the tooth). The results of the von Mises stress on the implant fixture, the elastic strain, and principal value of stress on the crestal marginal bone were analyzed. The axial load direction was comparable in the von Mises stress values in all groups, which indicated it was not necessary to use splinted crowns. The elastic strain values in the axial and oblique directions were within the limits of Frost's mechanostat theory. The principal value of stress in all groups were under the threshold of the compressive stress and tensile strength of cortical bone. In the oblique and lateral directions, the splinted crown showed better results for both the von Mises stress, elastic strain, and principal value of stress than the non-splinted crown. In conclusion, category 2 NDIs can be used in the upper premolar region of aging patients in the case of insufficient bone for category 3 NDI restorations.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 46 条
[1]   Clinical and radiographic peri-implant health status around narrow diameter implant-supported single and splinted crowns [J].
Al-Aali, Khulud Abdulrahman ;
ArRejaie, Aws S. ;
Alrahlah, Ali ;
AlFawaz, Yasser F. ;
Abduljabbar, Tariq ;
Vohra, Fahim .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (02) :386-390
[2]   Ten-Year Retrospective Follow-Up Study of the TiOblast™ Dental Implant [J].
Al-Nawas, Bilal ;
Kaemmerer, Peer W. ;
Morbach, Thomas ;
Ladwein, Catharina ;
Wegener, Joachim ;
Wagner, Wilfried .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (01) :127-134
[3]   Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis [J].
Araujo Lemos, Cleidiel Aparecido ;
Verri, Fellippo Ramos ;
Santiago Junior, Joel Ferreira ;
de Souza Batista, Victor Eduardo ;
Kemmoku, Daniel Takanori ;
Noritomi, Pedro Yoshito ;
Pellizzer, Eduardo Piza .
JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018
[4]   THE INFLUENCE OF IMPLANT DIAMETER AND LENGTH ON STRESS DISTRIBUTION OF OSSEOINTEGRATED IMPLANTS RELATED TO CRESTAL BONE GEOMETRY: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS [J].
Baggi, Luigi ;
Cappelloni, Ilaria ;
Di Girolamo, Michele ;
Maceri, Franco ;
Vairo, Giuseppe .
JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06) :422-431
[5]   Finite Element Analysis of Stress Distribution with Splinted and Nonsplinted Maxillary Anterior Fixed Prostheses Supported by Zirconia or Titanium Implants [J].
Bal, Bilge Turhan ;
Caglar, Alper ;
Aydin, Cemal ;
Yilmaz, Handan ;
Bankoglu, Merve ;
Eser, Atilim .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) :E27-E38
[6]   Comparative analysis of stress distribution in one-piece and two-piece implants with narrow and extra-narrow diameters: A finite element study [J].
Barbosa, Fabricia Teixeira ;
Silveira Zanatta, Luiz Carlos ;
Rendohl, Edelcio de Souza ;
Gehrke, Sergio Alexandre .
PLOS ONE, 2021, 16 (02)
[7]   Effects of the 3DP process parameters on mechanical properties of polylactic acid part used for medical purposes [J].
Chaitat, Sunthorn ;
Chantarapanich, Nattapon ;
Wanchat, Sujin .
RAPID PROTOTYPING JOURNAL, 2022, 28 (01) :143-160
[8]   Experimental evaluation of stress distribution with narrow diameter implants: A finite element analysis [J].
Cinel, Sezgi ;
Celik, Ersan ;
Sagirkaya, Elcin ;
Sahin, Onur .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03) :417-425
[9]   Finite element analysis in implant dentistry: State of the art and future directions [J].
Falcinelli, Cristina ;
Valente, Francesco ;
Vasta, Marcello ;
Traini, Tonino .
DENTAL MATERIALS, 2023, 39 (06) :539-556
[10]  
Frost HM., 1989, Structure, functional, and adaptation of compact bone