Design and experimental analysis of a shell and tube vapor generator for solar thermal vapor absorption refrigeration

被引:2
作者
Jadhav, Akash [1 ]
Raut, Devendra [1 ]
Kalamkar, Vilas R. [1 ]
机构
[1] Visvesvaraya Natl Inst Technol, Dept Mech Engn, Nagpur 440010, India
关键词
Vapor absorption refrigeration system; Solar thermal energy; Vapor generation; Shell and tube heat exchanger; PERFORMANCE EVALUATION; ENERGY-STORAGE; CHILLER DRIVEN; OPTIMIZATION; SYSTEM; LIBR;
D O I
10.1016/j.applthermaleng.2023.120694
中图分类号
O414.1 [热力学];
学科分类号
摘要
The generator is a crucial component of absorption refrigeration system as it provides a major input to the system. The overall performance of the absorption system mainly depends on vapor generation rate in a generator. Various studies are available in the literature on LiBr-H2O vapor absorption refrigeration systems. However, all these studies are focused on the performance of high-capacity commercial systems. Further, detailed analysis and feasibility of generator designs is not well explored though it is an important component of the system. Thus, present novel study is aimed to provide the idea about generator design and performance for a low-capacity system useful for residential applications. The objective of the present work is to investigate the shell and tube heat exchanger as a vapor generator for a vapor absorption refrigeration system experimentally. A LiBr-H2O vapor absorption refrigeration system requires water separation from LiBr in the vapor generator. The vapor generation depends on the saturation temperature and pressure. In this study, a shell and tube heat exchanger is designed for a vapor absorption refrigeration system of 0.5 ton of refrigeration. The experimental investigations are carried out at different operating conditions to evaluate the unit's performance and define its suitability for low-capacity absorption refrigeration system. Considering the output temperature of hot water from the solar thermal collector (80 -90 degrees C) and pressure restrictions on the vapor generation process due to the crystallization of lithium bromide, the presented heat exchanger design is evaluated for pressure ranging be-tween-0.90 bar and-0.65 bar. The experimental evaluation revealed that the heat exchanger is the most effective when the inlet temperature is 80 degrees C at a flow rate of 3 L per minute, and the initial pressure is-0.65 bar, while it is least effective for-0.90 bar. Further, vapor generation is greatest at-0.90 bar and lowest at-0.65 bar. The given configuration is suitable for an absorption system of cooling capacity 0.16 to 0.3 TR, as it can supply the vapor at the required flow rate at a given saturation temperature and pressure suitable for the de -absorption of water from LiBr.
引用
收藏
页数:13
相关论文
共 48 条
[1]   Feasibility and Basic Design of Solar Integrated Absorption Refrigeration for an Industry [J].
Akhtar, Saad ;
Khan, Tariq S. ;
Ilyas, Saad ;
Alshehhi, Mohamed S. .
CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 :508-513
[2]   Achieving annual and monthly net-zero energy of existing building in hot climate [J].
AlAjmi, Ali ;
Abou-Ziyan, Hosny ;
Ghoneim, Adel .
APPLIED ENERGY, 2016, 165 :511-521
[3]  
[Anonymous], 2019, World Energy Outlook, DOI DOI 10.1049/EP.1977.0180
[4]  
Arora R.C., 2010, BOOK REFRIGERATION A
[5]  
Balamurugan A.M. P., HEAT MASS TRANSFER S
[6]   The design of an evaporator/absorber and thermodynamic analysis of a vapor absorption chiller driven by solar energy [J].
Bell, IA ;
AlDaini, AJ ;
Ali, HA ;
AbdelGayed, RG ;
Duckers, L .
RENEWABLE ENERGY, 1996, 9 (1-4) :657-660
[7]  
Bergman I.D., 2015, LAVINE FUNDAMENTALS, DOI [10.1007/978-3-319-15793-1_19, DOI 10.1007/978-3-319-15793-1_19]
[8]   Experimental and analytical study on an air-cooled single effect LiBr-H2O absorption chiller driven by evacuated glass tube solar collector for cooling application in residential buildings [J].
Chen, J. F. ;
Dai, Y. J. ;
Wang, R. Z. .
SOLAR ENERGY, 2017, 151 :110-118
[9]   Experimental study on performance change with time of solar adsorption refrigeration system [J].
Chen, Q. F. ;
Du, S. W. ;
Yuan, Z. X. ;
Sun, T. B. ;
Li, Y. X. .
APPLIED THERMAL ENGINEERING, 2018, 138 :386-393
[10]   Design optimization of shell-and-tube heat exchangers [J].
Costa, Andre L. H. ;
Queiroz, Eduardo M. .
APPLIED THERMAL ENGINEERING, 2008, 28 (14-15) :1798-1805