Determination of Immunoglobulin E (IgE) in Serum by a Laboratory-Constructed Time-Resolved Fluorescent Nanosphere-Based Immunochromatographic Test Strip

被引:0
|
作者
Guo, Qiaoyun [1 ,2 ]
Wang, Deyin [1 ,2 ]
Zeng, Min [3 ]
Gong, Zishan [2 ]
Deng, Xiyan [3 ]
Liu, Jiyang [2 ]
Zhang, Liyan [1 ,4 ]
Zhang, Yanwen [2 ,5 ]
Xu, Liang [2 ,3 ,5 ]
机构
[1] Tianjin Univ Finance & Econ, Tianjin, Peoples R China
[2] Tianjin Med Coll, Tianjin, Peoples R China
[3] Tianjin Med Univ, Sch Pharm, Tianjin Key Lab Technol Enabling Dev Clin Therapeu, Tianjin, Peoples R China
[4] Tianjin Univ Finance & Econ, Innovat & Entrepreneurship Res Ctr, 25 Zhujiang Rd, Tianjin 300221, Peoples R China
[5] Tianjin Med Coll, Sch Pharm & Biol Technol, 14 Liulin Rd, Tianjin 300222, Peoples R China
基金
中国国家自然科学基金;
关键词
Allergic diseases; immunochromatographic test strip; immunoglobulin E; laboratory-constructed time resolved fluorescent nanospheres; point-of-care testing (POCT); QUANTITATIVE DETECTION; DIAGNOSIS; ALLERGY; ASSAY;
D O I
10.1080/00032719.2022.2152039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Allergic diseases (AD) are significant and hence rapid and accurate immunoglobulin E (IgE) determination is critical for diagnosis and treatment. Herein, a rapid, sensitive, and quantitative immunochromatographic test strip was designed for assaying IgE in human serum based on laboratory-constructed time-resolved fluorescent nanospheres (LTRFNs) which have large specific surface areas and multiple carboxyl groups in the outer layer with efficient coupling to the antibodies. Using the stable fluorescence created by the LTRFNs, the test strip accurately quantified IgE for early diagnosis with a detection limit of 4.2 ng/mL. The test strip has a long working range from 8 to 1024 ng/mL, and excellent performance, including high sensitivity, good inter-batch repeatability, and stability. Furthermore, the analysis of 30 clinical serum samples showed good correlation with a commercial chemiluminescence protocol. Therefore, the laboratory-constructed test strip has potential as a novel tool for clinical diagnosis and a rapid home test for allergic diseases.
引用
收藏
页码:1946 / 1961
页数:16
相关论文
共 18 条
  • [1] A Europium Nanosphere-Based Time-Resolved Fluorescent Immunochromatographic Assay for the Rapid Screening of 4,4'-Dinitrocarbanilide: Aiming at Improving Strip Method Performance
    Zou, Ming
    Yin, Yongkang
    Guo, Liuchuan
    Zhang, Qidi
    Li, Jinyan
    Zhang, Hong
    Song, Qian
    Li, Zhaojie
    Wang, Li
    Ao, Xiang
    Liang, Xiao
    BIOSENSORS-BASEL, 2023, 13 (05):
  • [2] Development of a time-resolved immunochromatographic test strip for rapid and quantitative determination of GFAP in serum
    Wang, Yupeng
    Yu, Zhiyong
    Ning, Zhenqiu
    Li, Minghui
    Li, Weiping
    Zhong, Yizhe
    Chen, Huiqiang
    Zhang, Xi
    Tang, Xialin
    Cheng, Xiao
    Li, Laiqing
    Aigul, Abduldayeva
    Zan, Jie
    MICROCHIMICA ACTA, 2024, 191 (06)
  • [3] Rapid, on-site quantitative determination of mycotoxins in grains using a multiple time-resolved fluorescent microsphere immunochromatographic test strip
    Liang, Junfa
    Li, Xuewei
    Huang, Bin
    Pan, Yupeng
    Zhuang, Zile
    Ye, Qiuxiong
    Peng, Cheng
    Deng, Huangyi
    Yi, Yunting
    Zhang, Binbin
    Chen, Peiyi
    Chen, Xuncai
    BIOSENSORS & BIOELECTRONICS, 2024, 258
  • [4] A fluorescent nanosphere-based immunochromatography test strip for ultrasensitive and point-of-care detection of tetanus antibody in human serum
    Chen, Juan
    Meng, Hong-Min
    An, Ying
    Liu, Juanzu
    Yang, Ran
    Qu, Lingbo
    Li, Zhaohui
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (05) : 1151 - 1158
  • [5] A fluorescent nanosphere-based immunochromatography test strip for ultrasensitive and point-of-care detection of tetanus antibody in human serum
    Juan Chen
    Hong-Min Meng
    Ying An
    Juanzu Liu
    Ran Yang
    Lingbo Qu
    Zhaohui Li
    Analytical and Bioanalytical Chemistry, 2020, 412 : 1151 - 1158
  • [6] Rapid and quantitative detection of urinary Cyfra21-1 using fluorescent nanosphere-based immunochromatographic test strip for diagnosis and prognostic monitoring of bladder cancer
    Lei, Qifang
    Zhao, Linlin
    Ye, Shuixian
    Sun, Yue
    Xie, Fangjie
    Zhang, Hong
    Zhou, Fangjian
    Wu, Song
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2019, 47 (01) : 4266 - 4272
  • [7] Determination of parathion by time-resolved fluorescence immunochromatographic assay based on nanobody: Aiming at improving strip sensitivity
    Pang, Jiarui
    Guo, Mingwei
    Wang, Yu
    Bi, Chaohui
    Xu, Zhenlin
    Shen, Yudong
    Xiao, Zhili
    Wen, Peng
    Yang, Jinyi
    Wang, Hong
    TALANTA, 2025, 285
  • [8] Development of a time-resolved immunochromatographic test strip for rapid and quantitative determination of retinol-binding protein 4 in urine
    Guo, Wenjie
    Yu, Zhiyong
    Li, Tianxu
    Lu, Lingfei
    Lin, Huiqi
    Liao, Ying
    Zheng, Yanghao
    Liu, Yuntao
    Alevtinovna, Glaskovich Maria
    Barysavets, Dzmitry S.
    Chen, Jinping
    Zan, Jie
    Lu, Jiandong
    MICROCHIMICA ACTA, 2024, 191 (06)
  • [9] Development of a time-resolved immunochromatographic test strip for simultaneously rapid and quantitative determination of phorate and dichlorodiphenyltrichloroethane residues in herbal medicines
    Chen, Xiaomin
    Zhang, Yuting
    Guo, Wenjie
    Zhou, Xiaoli
    Tang, Xialin
    Wang, Yupeng
    Xiao, Xiao
    Zhang, Jian
    Zan, Jie
    Ding, Yanbing
    MICROCHEMICAL JOURNAL, 2025, 212
  • [10] Broad-specificity time-resolved fluorescent immunochromatographic strip for simultaneous detection of various organophosphorus pesticides based on indirect probe strategy
    Dong, Haowei
    Xu, Deyan
    Wang, Guanjie
    Meng, Xiaoya
    Sun, Xia
    Yang, Qingqing
    Guo, Yemin
    Zhu, Yelong
    ANALYTICAL METHODS, 2022, 14 (10) : 1051 - 1059