Rapid monitoring of SARS-CoV-2 variants of concern through high-resolution melt analysis

被引:4
作者
Diotallevi, Aurora [1 ]
Buffi, Gloria [1 ]
Barocci, Simone [2 ]
Ceccarelli, Marcello [1 ,2 ]
Bencardino, Daniela [1 ]
Andreoni, Francesca [1 ,2 ]
Orlandi, Chiara [1 ]
Ferri, Marilisa [2 ]
Vandini, Daniela [2 ]
Menzo, Stefano [3 ]
Carlotti, Eugenio [4 ]
Casabianca, Anna [1 ]
Magnani, Mauro [1 ]
Galluzzi, Luca [1 ]
机构
[1] Univ Urbino Carlo Bo, Sect Biotechnol, Dept Biomol Sci, I- 60132 Fano, PU, Italy
[2] Azienda Sanit Terr AST Pesaro & Urbino, Dept Clin Pathol, I-61029 Urbino, PU, Italy
[3] Azienda Osped Univ Marche, Virol Lab, I-60126 Ancona, AN, Italy
[4] Azienda Sanit Terr AST Pesaro & Urbino Marche, Dept Prevent, I-61029 Urbino, PU, Italy
关键词
MULTIPLE SEQUENCE ALIGNMENT; REAL-TIME PCR; RESISTANCE; TOOL;
D O I
10.1038/s41598-023-48929-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The current global pandemic of COVID-19 is characterized by waves of infection due to the emergence of new SARS-CoV-2 variants carrying mutations on the Spike (S) protein gene. Since autumn 2020 many Variants of Concern (VOC) have been reported: Alpha/B.1.1.7, Beta/B.1.351, Gamma/P.1, Delta/B.1.617.2, Omicron/B.1.1.529, and sublineages. Surveillance of genomic variants is currently based on whole-genome sequencing (WGS) of viral genomes on a random fraction of samples positive to molecular tests. WGS involves high costs, extended analysis time, specialized staff, and expensive instruments compared to a PCR-based test. To rapidly identify the VOCs in positive samples, six assays based on real-time PCR and high-resolution melting (HRM) were designed on the S gene and applied to 120 oro/nasopharyngeal swab samples collected from October 2020 to June 2022 (106 positive and 14 negative samples). Overall, the assays showed 100% specificity and sensitivity compared with commercial PCR tests for COVID-19. Moreover, 104 samples out of 106 (98.1%) were correctly identified as follows: 8 Wuhan (wild type), 12 Alpha, 23 Delta, 46 Omicron BA.1/BA.1.1, 15 Omicron BA.2/BA.4/BA.5. With our lab equipment, about 10 samples can be processed every 3 h at the cost of less than euro 10 ($ 10.60) per sample, including RNA extraction. The implementation of this approach could help local epidemiological surveillance and clinical decision-making.
引用
收藏
页数:10
相关论文
共 46 条
[41]  
Weisblum Yiska, 2020, bioRxiv, DOI [10.7554/eLife.61312, 10.1101/2020.07.21.214759]
[42]  
White H., 2006, Evaluation of RotorGene 6000 (Corbett Life Science), HR1 and 384 well LightScanner
[43]   Rapid Identification and Discrimination of Brucella Isolates by Use of Real-Time PCR and High-Resolution Melt Analysis [J].
Winchell, Jonas M. ;
Wolff, Bernard J. ;
Tiller, Rebekah ;
Bowen, Michael D. ;
Hoffmaster, Alex R. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (03) :697-702
[44]  
World Health Organization, 2022, Tracking SARS-CoV2 variants
[45]   Primer-BLAST: A tool to design target-specific primers for polymerase chain reaction [J].
Ye, Jian ;
Coulouris, George ;
Zaretskaya, Irena ;
Cutcutache, Ioana ;
Rozen, Steve ;
Madden, Thomas L. .
BMC BIOINFORMATICS, 2012, 13 :134
[46]   Evaluation of a Rapid and Accessible Reverse Transcription-Quantitative PCR Approach for SARS-CoV-2 Variant of Concern Identification [J].
Yeung, Priscilla S-W ;
Wang, Hannah ;
Sibai, Mamdouh ;
Solis, Daniel ;
Yamamoto, Fumiko ;
Iwai, Naomi ;
Jiang, Becky ;
Hammond, Nathan ;
Truong, Bernadette ;
Bihon, Selamawit ;
Santos, Suzette ;
Mar, Marilyn ;
Mai, Claire ;
Mfuh, Kenji O. ;
Miller, Jacob A. ;
Huang, ChunHong ;
Sahoo, Malaya K. ;
Zehnder, James L. ;
Pinsky, Benjamin A. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2022, 60 (05)