An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

被引:0
作者
Ghani, Muhammad Usman [1 ]
Makeev, Andrey [1 ]
Manus, Joseph A. [1 ]
Glick, Stephen J. [1 ]
Ghammraoui, Bahaa [1 ]
机构
[1] United States Food & Drug Adm, Div Imaging Diagnost & Software Reliabil, Ctr Devices & Radiol Hlth, Off Sci & Engn Labs, Silver Spring, MD 20993 USA
关键词
Geometric calibration; sphericity; symmetry; photon counting detectors; cone beam CTs; COMPUTED-TOMOGRAPHY; PARAMETERS;
D O I
10.3233/XST-230007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors' limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.
引用
收藏
页码:865 / 877
页数:13
相关论文
共 50 条
  • [31] Comparison of spectral CT imaging methods based a photon-counting detector: Experimental study
    Lee, Youngjin
    Lee, Seungwan
    Kim, Hee-Joung
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 815 : 68 - 74
  • [32] Chord-based image reconstruction in cone-beam CT with a curved detector
    Zuo, Nianming
    Xia, Dan
    Zou, Yu
    Jiang, Tianzi
    Pan, Xiao-Chuan
    MEDICAL PHYSICS, 2006, 33 (10) : 3743 - 3757
  • [33] Enhanced material separation with a quasi-monochromatic CT imaging method using a photon counting detector
    Wang, Sen
    Xing, Yuxiang
    Zhang, Li
    Xu, Xiaofei
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 881 : 9 - 15
  • [34] K-edge energy-based calibration method for photon counting detectors
    Ge, Yongshuai
    Ji, Xu
    Zhang, Ran
    Li, Ke
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01)
  • [35] An investigation into factors affecting electron density calibration for a megavoltage cone-beam CT system
    Hughes, Jessica
    Holloway, Lois C.
    Quinn, Alexandra
    Fielding, Andrew
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (05): : 93 - 107
  • [36] Performance evaluation of an image-based measurement method used to determine the geometric errors of cone-beam CT instruments
    Baldo, Crhistian R.
    Probst, Gabriel M.
    Dewulf, Wim
    ADVANCES IN INDUSTRIAL AND MANUFACTURING ENGINEERING, 2020, 1
  • [37] Deep learning-based material decomposition of iodine and calcium in mobile photon counting detector CT
    Han, Kwanhee
    Ryu, Chang Ho
    Lee, Chang-Lae
    Han, Tae Hee
    PLOS ONE, 2024, 19 (07):
  • [38] Triple-source saddle-curve cone-beam photon counting CT image reconstruction: A simulation study
    Xin, Lin
    Zhuo, Weihai
    Liu, Qian
    Xie, Tianwu
    Zaidi, Habib
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2024, 34 (03): : 408 - 418
  • [39] High Resolution, Full Field-of-View, Whole Body Photon-Counting Detector CT: System Assessment and Initial Experience
    Rajendran, Kishore
    Marsh, Jeffrey
    Petersilka, Martin
    Henning, Andre
    Shanblatt, Elisabeth
    Schmidt, Bernhard
    Flohr, Thomas
    Fletcher, Joel
    McCollough, Cynthia
    Leng, Shuai
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [40] Theoretical Comparison of a Dual Energy System and Photon Counting Silicon Detector Used for Material Quantification in Spectral CT
    Yveborg, Moa
    Danielsson, Mats
    Bornefalk, Hans
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (03) : 796 - 806