An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

被引:0
|
作者
Ghani, Muhammad Usman [1 ]
Makeev, Andrey [1 ]
Manus, Joseph A. [1 ]
Glick, Stephen J. [1 ]
Ghammraoui, Bahaa [1 ]
机构
[1] United States Food & Drug Adm, Div Imaging Diagnost & Software Reliabil, Ctr Devices & Radiol Hlth, Off Sci & Engn Labs, Silver Spring, MD 20993 USA
关键词
Geometric calibration; sphericity; symmetry; photon counting detectors; cone beam CTs; COMPUTED-TOMOGRAPHY; PARAMETERS;
D O I
10.3233/XST-230007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors' limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.
引用
收藏
页码:865 / 877
页数:13
相关论文
共 50 条
  • [21] Geometric calibration method based micro-CT system for small-animal imaging
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Rong, Junyan
    Li, Yanming
    Zheng, Hairong
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [22] First Clinical Photon-counting Detector CT System: Technical Evaluation
    Rajendran, Kishore
    Petersilka, Martin
    Henning, Andre
    Shanblatt, Elisabeth R.
    Schmidt, Bernhard
    Flohr, Thomas G.
    Ferrero, Andrea
    Baffour, Francis
    Diehn, Felix E.
    Yu, Lifeng
    Rajiah, Prabhakar
    Fletcher, Joel G.
    Leng, Shuai
    McCollough, Cynthia H.
    RADIOLOGY, 2022, 303 (01) : 130 - 138
  • [23] High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging
    Abu Anas, Emran Mohammad
    Kim, Jae Gon
    Lee, Soo Yeol
    Hasan, Md Kamrul
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (19): : 6495 - 6519
  • [24] Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology
    Leng, Shuai
    Bruesewitz, Michael
    Tao, Shengzhen
    Rajendran, Kishore
    Halaweish, Ahmed F.
    Campeau, Norbert G.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    RADIOGRAPHICS, 2019, 39 (03) : 729 - 743
  • [25] Stable and Robust Geometric Self-Calibration for Cone-Beam CT Using Mutual Information
    Muders, Jens
    Hesser, Juergen
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 202 - 217
  • [26] A Parameter Division Based Method for the Geometrical Calibration of X-Ray Industrial Cone-Beam CT
    Xiao, Kai
    Han, Yu
    Xi, Xiaoqi
    Yan, Bin
    Bu, Haibing
    Li, Lei
    IEEE ACCESS, 2018, 6 : 48970 - 48977
  • [27] A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System A Feasibility Study
    Zhou, Wei
    Michalak, Gregory J.
    Weaver, Jayse M.
    Gong, Hao
    Yu, Lifeng
    McCollough, Cynthia H.
    Leng, Shuai
    INVESTIGATIVE RADIOLOGY, 2020, 55 (04) : 226 - 232
  • [28] Determination of Optimal Image Type and Lowest Detectable Concentration for Iodine Detection on a Photon Counting Detector Based Multi-Energy CT System
    Zhou, Wei
    Schornak, Rachel
    Michalak, Gregory
    Weaver, Jayse
    Abdurakhimova, Dilbar
    Ferrero, Andrea
    Fetterly, Kenneth A.
    McCollough, Cynthia H.
    Leng, Shuai
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [29] Fully automatic online geometric calibration for non-circular cone-beam CT orbits using fiducials with unknown placement
    Ma, Yiqun Q.
    Reynolds, Tess
    Ehtiati, Tina
    Weiss, Clifford
    Hong, Kelvin
    Theodore, Nicholas
    Gang, Grace J.
    Stayman, J. Webster
    MEDICAL PHYSICS, 2024, 51 (05) : 3245 - 3264
  • [30] Self-calibration method for geometric parameters based on feature point projection trajectories in Cone-beam Computed Laminography
    Sun, Yanmin
    Han, Yu
    Han, Hui
    Tan, Siyu
    Wang, Chunhui
    Li, Lei
    Yan, Bin
    Zhang, Yuan
    MEASUREMENT, 2025, 240