Accuracy of dental implant placement with or without the use of a dynamic navigation assisted system: A randomized clinical trial

被引:18
|
作者
Jorba-Garcia, Adria [1 ]
Bara-Casaus, Jose Javier [2 ]
Camps-Font, Octavi [3 ,4 ]
Sanchez-Garces, Maria angeles [3 ,4 ]
Figueiredo, Rui [3 ,4 ]
Valmaseda-Castellon, Eduard [3 ,4 ]
机构
[1] Univ Barcelona, Fac Med & Hlth Sci, Master Oral Surg & Implantol, Barcelona, Spain
[2] Univ Hosp Sagrat Cor, Dent & Maxillofacial Inst, Barcelona, Spain
[3] Univ Barcelona, Fac Med & Hlth Sci, Oral Surg, Barcelona, Spain
[4] IDIBELL Inst, Bellvitge Biomed Res Inst, Barcelona, Spain
关键词
computer-assisted; dental implants; dental prosthesis; implant-supported; surgery; surgical navigation systems; COMPUTER-TECHNOLOGY APPLICATIONS; DENTISTRY; SURGERY; TOMOGRAPHY; AESTHETICS;
D O I
10.1111/clr.14050
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesTo assess dental implant placement accuracy with a dynamic computer-assisted implant surgery (dCAIS) system and a freehand approach. Secondarily, to compare the patients' perception and quality of life (QoL) with the two approaches. MethodsA double-arm randomized clinical trial was conducted. Consecutive partially edentulous patients were randomly allocated to the dCAIS or standard freehand approach groups. Implant placement accuracy was evaluated by overlapping the preoperative and postoperative Cone Beam Computer Tomographs (CBCT) and recording linear deviations at the implant apex and platform (in mm) and angular deviations (in degrees). Questionnaires recorded self-reported satisfaction, pain and QoL during surgery and postoperatively. ResultsThirty patients (22 implants) were enrolled in each group. One patient was lost to follow-up. A significant difference (p < .001) in mean angular deviation was found between the dCAIS (4.02 degrees; 95% CI: 2.85 to 5.19) and the FH (7.97 degrees; 95% CI: 5.36 to 10.58) groups. Linear deviations were significantly lower in the dCAIS group, except for the apex vertical deviation, where no differences were found. Although dCAIS took 14 min longer (95% CI: 6.43 to 21.24; p < .001), patients in both groups considered the surgical time acceptable. Postoperative pain and analgesic consumption during the first postoperative week were similar between groups and self-reported satisfaction was very high. ConclusiondCAIS systems significantly increase the accuracy of implant placement in partially edentulous patients in comparison with the conventional freehand approach. However, they increase the surgical time significantly and do not seem to improve patient satisfaction or reduce postoperative pain.
引用
收藏
页码:438 / 449
页数:12
相关论文
共 50 条
  • [31] Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study
    Otaghsara, Seyedeh Sahar Taheri
    Joda, Tim
    Thieringer, Florian Markus
    JOURNAL OF DENTISTRY, 2023, 132
  • [32] Learning Curve and Comparison of Dynamic Implant Placement Accuracy Using a Navigation System in Young Professionals
    Spille, Johannes
    Helmstetter, Eva
    Kuebel, Paul
    Weitkamp, Jan-Tobias
    Wagner, Juliane
    Wieker, Henning
    Naujokat, Hendrik
    Floerke, Christian
    Wiltfang, Joerg
    Guelses, Aydin
    DENTISTRY JOURNAL, 2022, 10 (10)
  • [33] Accuracy of dental implant placement with a robotic system in partially edentulous patients: A prospective, single-arm clinical trial
    Chen, Wei
    Al-Taezi, Khulood Ali
    Chu, Catherine Huihan
    Shen, Yue
    Wu, Jin
    Cai, Kunzhan
    Chen, Peng
    Tang, Chunbo
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (07) : 707 - 718
  • [34] A Randomized Controlled Clinical Trial Comparing Conventional and Computer-Assisted Implant Planning and Placement in Partially Edentulous Patients. Part 4: Accuracy of Implant Placement
    Schneider, David
    Sancho-Puchades, Manuel
    Mir-Mari, Javier
    Muehlemann, Sven
    Jung, Ronald
    Haemmerle, Christoph
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2019, 39 (04) : E111 - E122
  • [35] Three-dimensional Accuracy of Angled Dental Implant Placement: A Comparison Study of the Dynamic Navigation System and Free-hand Method
    Ustek, Gunes Kenan
    Simsek, Hasan Onur
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2021, 22 : 119 - 128
  • [36] Accuracy of implant placement via dynamic navigation and autonomous robotic computer-assisted implant surgery methods: A retrospective study
    Zhang, Sihui
    Cai, Qin
    Chen, Weiyi
    Lin, Yuxuan
    Gao, Yan
    Wu, Dong
    Chen, Jiang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (02) : 220 - 229
  • [37] Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Navigation for Dental Implant Placement: An In Vitro Study
    Mediavilla Guzman, Alfonso
    Riad Deglow, Elena
    Zubizarreta-Macho, Alvaro
    Agustin-Panadero, Ruben
    Hernandez Montero, Sofia
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (12)
  • [38] Effect of Clinical Experience on Accuracy of Implant Placement Using Dynamic Navigation and Static Guidance: An In Vitro Study
    Fang, Qiao
    Lozada, Jaime
    Kan, Joseph
    Al-Ardah, Aladdin
    Li, Yiming
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (06) : 626 - 635
  • [39] Comparison of the accuracy of implant position for two-implants supported fixed dental prosthesis using static and dynamic computer-assisted implant surgery: A randomized controlled clinical trial
    Yimarj, Paweena
    Subbalekha, Keskanya
    Dhanesuan, Kanit
    Siriwatana, Kiti
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (06) : 672 - 678
  • [40] Dynamic Navigation in Dental Implantology: The Influence of Surgical Experience on Implant Placement Accuracy and Operating Time. An in Vitro Study
    Pellegrino, Gerardo
    Bellini, Pierantonio
    Cavallini, Pier Francesco
    Ferri, Agnese
    Zacchino, Andrea
    Taraschi, Valerio
    Marchetti, Claudio
    Consolo, Ugo