共 50 条
Accuracy of dental implant placement with or without the use of a dynamic navigation assisted system: A randomized clinical trial
被引:21
|作者:
Jorba-Garcia, Adria
[1
]
Bara-Casaus, Jose Javier
[2
]
Camps-Font, Octavi
[3
,4
]
Sanchez-Garces, Maria angeles
[3
,4
]
Figueiredo, Rui
[3
,4
]
Valmaseda-Castellon, Eduard
[3
,4
]
机构:
[1] Univ Barcelona, Fac Med & Hlth Sci, Master Oral Surg & Implantol, Barcelona, Spain
[2] Univ Hosp Sagrat Cor, Dent & Maxillofacial Inst, Barcelona, Spain
[3] Univ Barcelona, Fac Med & Hlth Sci, Oral Surg, Barcelona, Spain
[4] IDIBELL Inst, Bellvitge Biomed Res Inst, Barcelona, Spain
关键词:
computer-assisted;
dental implants;
dental prosthesis;
implant-supported;
surgery;
surgical navigation systems;
COMPUTER-TECHNOLOGY APPLICATIONS;
DENTISTRY;
SURGERY;
TOMOGRAPHY;
AESTHETICS;
D O I:
10.1111/clr.14050
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
ObjectivesTo assess dental implant placement accuracy with a dynamic computer-assisted implant surgery (dCAIS) system and a freehand approach. Secondarily, to compare the patients' perception and quality of life (QoL) with the two approaches. MethodsA double-arm randomized clinical trial was conducted. Consecutive partially edentulous patients were randomly allocated to the dCAIS or standard freehand approach groups. Implant placement accuracy was evaluated by overlapping the preoperative and postoperative Cone Beam Computer Tomographs (CBCT) and recording linear deviations at the implant apex and platform (in mm) and angular deviations (in degrees). Questionnaires recorded self-reported satisfaction, pain and QoL during surgery and postoperatively. ResultsThirty patients (22 implants) were enrolled in each group. One patient was lost to follow-up. A significant difference (p < .001) in mean angular deviation was found between the dCAIS (4.02 degrees; 95% CI: 2.85 to 5.19) and the FH (7.97 degrees; 95% CI: 5.36 to 10.58) groups. Linear deviations were significantly lower in the dCAIS group, except for the apex vertical deviation, where no differences were found. Although dCAIS took 14 min longer (95% CI: 6.43 to 21.24; p < .001), patients in both groups considered the surgical time acceptable. Postoperative pain and analgesic consumption during the first postoperative week were similar between groups and self-reported satisfaction was very high. ConclusiondCAIS systems significantly increase the accuracy of implant placement in partially edentulous patients in comparison with the conventional freehand approach. However, they increase the surgical time significantly and do not seem to improve patient satisfaction or reduce postoperative pain.
引用
收藏
页码:438 / 449
页数:12
相关论文