The Remove-the-Mask Open-Source head and neck Surface-Guided radiation therapy system

被引:0
作者
Ben Bouchta, Youssef [1 ]
Gardner, Mark [1 ]
Sengupta, Chandrima [1 ]
Johnson, Julia [1 ]
Keall, Paul [1 ]
机构
[1] Univ Sydney, Camperdown, NSW 2050, Australia
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2024年 / 29卷
关键词
Surface-Guided Radiotherapy; Intra-Fraction Motion Monitoring; Open-Source; Head And Neck Radiotherapy; Image-Guided Radiotherapy; PATIENT SELF-REPORT; IMAGING-SYSTEM; RADIOTHERAPY; CANCER; IMMOBILIZATION; CARCINOMA; ANXIETY;
D O I
10.1016/j.phro.2024.100541
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: Surface Guided Radiotherapy (SGRT) for head and neck radiotherapy is challenging as obstructions are common and non-rigid facial motion can compromise surface accuracy. The purpose of this work was to develop and benchmark the Remove the Mask (RtM) SGRT system, an open-source system especially designed to address the challenges faced in radiotherapy of head and neck cancer. Materials and Methods: The accuracy of the RtM SGRT system was benchmarked using a head phantom positioned on a robotic motion platform capable of sub-millimetre accuracy which was used to induce unidirectional shifts and to reproduce three real head motion traces. We also assessed the accuracy of the system in ten humans volunteers. The ground truth motion of the volunteers was obtained using a commercial motion capture system with an accuracy < 0.3 mm. Results: The mean tracking error of the RtM SGRT system for the ten volunteers was of -0.1 +/- 0.4 mm -0.6 +/- 0.6 mm and 0.3 +/- 0.2 mm, and 0.0 +/- 0.2(degrees) 0.0 +/- 0.1(degrees) and 0.0 +/- 0.2(degrees) for translations and rotations along the left-right, superior-inferior and anterior-posterior axes respectively and we also found similar results in measurements with the head phantom. Forced facial motion was associated with lower tracking accuracy. The RtM SGRT system achieved submillimetre accuracy. Conclusion: The RtM SGRT system is a low-cost, easy to build and open-source SGRT system that can achieve an accuracy that meets international commissioning guidelines. Its open-source and modular design allows for the development and easy translation of novel surface tracking techniques.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] An open-source LED array illumination system for automated multiwell plate cell culture photodynamic therapy experiments
    Zhang, Kai
    Timilsina, Sudip
    Waguespack, Matthew
    Kercher, Eric M.
    Spring, Bryan Q.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [42] Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments
    Merrill, Robb
    Odeen, Henrik
    Dillon, Christopher
    Bitton, Rachelle
    Ghanouni, Pejman
    Payne, Allison
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 679 - 690
  • [43] Surface-Guided Patient Setup Versus Traditional Tattoo Markers for Radiation Therapy: Is Tattoo-Less Setup Feasible for Thorax, Abdomen and Pelvis Treatment?
    Zhao, Hui
    Paxton, Adam
    Sarkar, Vikren
    Price, Ryan G.
    Huang, Jessica
    Su, Fan -Chi Frances
    Li, Xing
    Rassiah, Prema
    Szegedi, Martin
    Salter, Bill
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (08)
  • [44] Optical Surface-guided Radiation Therapy for Upper and Lower Limb Sarcomas: An Analysis of Setup Errors and Clinical Target Volume-To-Planning Target Volume Margins
    Zhang, Yan-Xin
    Huan, Fu-Kui
    Wan, Bao
    Li, Zhao-Hui
    Li, Wei
    Zhu, Geng-Qiang
    Wang, Zhi-Wei
    Chen, Huan
    Hou, Lu
    Jing, Hao
    Wang, Shu-Lian
    Lu, Ning-Ning
    ADVANCES IN RADIATION ONCOLOGY, 2024, 9 (08)
  • [45] Cachexia induces head and neck changes in locally advanced oropharyngeal carcinoma during definitive cisplatin and image-guided volumetric-modulated arc radiation therapy
    Mazzola, R.
    Ricchetti, F.
    Fiorentino, A.
    Di Paola, G.
    Fersino, S.
    Levra, N. Giaj
    Ruggieri, R.
    Alongi, F.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2016, 70 (06) : 738 - 742
  • [46] Quantitative magnetic resonance imaging responses in head and neck cancer patients treated with magnetic resonance-guided hypofractionated radiation therapy
    Bonate, Ryan
    Awan, Musaddiq J.
    Himburg, Heather A.
    Wong, Stuart
    Shukla, Monica
    Tarima, Sergey
    Zenga, Joseph
    Paulson, Eric S.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2025, 33
  • [47] Comparative study on setup accuracy of marker-less surface-guided radiation therapy versus traditional skin marks in hypofractionated whole breast irradiation: A marker-free approach starting from CT simulation
    Jeong, Yuri
    Kim, Jung Hoon
    Oh, Jeong Geun
    Lee, Kang Kyoo
    Moon, Sun Rock
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2025, 18 (01)
  • [48] Single-Center Prospective Trial Investigating the Feasibility of Serial FDG-PET Guided Adaptive Radiation Therapy for Head and Neck Cancer
    Gouw, Zeno A. R.
    La Fontaine, Matthew D.
    Vogel, Wouter V.
    van de Kamer, Jeroen B.
    Sonke, Jan-Jakob
    Al-Mamgani, Abrahim
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (04): : 960 - 968
  • [49] An open-source software for monitoring intrafraction motion during external beam radiation therapy based on superimposition of contours of projected ROIs on cine-MV images
    Lessard, Remi
    Tremblay, Nicolas M.
    Plourde, Marc-emile
    Guillot, Mathieu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (08): : 173 - 182
  • [50] Two-dimensional and Three-dimensional Image-guided Evaluation of Patient Positioning for Intensity-modulated Radiation Therapy of Head and Neck Cancer
    Johari, Zul Iskandar
    Azmi, Nor Aniza
    Ab Muin, Nur Fa'izah
    Latiff, Rukiah A.
    Fadzil, Muhammad Safwan Ahmad
    Razali, Rosmizan Ahmad
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2023, 19 (05): : 915 - 926