The Remove-the-Mask Open-Source head and neck Surface-Guided radiation therapy system

被引:0
|
作者
Ben Bouchta, Youssef [1 ]
Gardner, Mark [1 ]
Sengupta, Chandrima [1 ]
Johnson, Julia [1 ]
Keall, Paul [1 ]
机构
[1] Univ Sydney, Camperdown, NSW 2050, Australia
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2024年 / 29卷
关键词
Surface-Guided Radiotherapy; Intra-Fraction Motion Monitoring; Open-Source; Head And Neck Radiotherapy; Image-Guided Radiotherapy; PATIENT SELF-REPORT; IMAGING-SYSTEM; RADIOTHERAPY; CANCER; IMMOBILIZATION; CARCINOMA; ANXIETY;
D O I
10.1016/j.phro.2024.100541
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: Surface Guided Radiotherapy (SGRT) for head and neck radiotherapy is challenging as obstructions are common and non-rigid facial motion can compromise surface accuracy. The purpose of this work was to develop and benchmark the Remove the Mask (RtM) SGRT system, an open-source system especially designed to address the challenges faced in radiotherapy of head and neck cancer. Materials and Methods: The accuracy of the RtM SGRT system was benchmarked using a head phantom positioned on a robotic motion platform capable of sub-millimetre accuracy which was used to induce unidirectional shifts and to reproduce three real head motion traces. We also assessed the accuracy of the system in ten humans volunteers. The ground truth motion of the volunteers was obtained using a commercial motion capture system with an accuracy < 0.3 mm. Results: The mean tracking error of the RtM SGRT system for the ten volunteers was of -0.1 +/- 0.4 mm -0.6 +/- 0.6 mm and 0.3 +/- 0.2 mm, and 0.0 +/- 0.2(degrees) 0.0 +/- 0.1(degrees) and 0.0 +/- 0.2(degrees) for translations and rotations along the left-right, superior-inferior and anterior-posterior axes respectively and we also found similar results in measurements with the head phantom. Forced facial motion was associated with lower tracking accuracy. The RtM SGRT system achieved submillimetre accuracy. Conclusion: The RtM SGRT system is a low-cost, easy to build and open-source SGRT system that can achieve an accuracy that meets international commissioning guidelines. Its open-source and modular design allows for the development and easy translation of novel surface tracking techniques.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Intensity-Modulated and Image-Guided Radiation Therapy for Head and Neck Cancers
    Chu, Karen Pat-Ming
    Le, Quynh-Thu
    IMRT IGRT SBRT- ADVANCES IN THE TREATMENT PLANNING AND DELIVERY OF RADIOTHERAPY, 2011, 43 : 217 - 254
  • [22] Use of surface-guided radiation therapy in combination with IGRT for setup and intrafraction motion monitoring during stereotactic body radiation therapy treatments of the lung and abdomen
    Heinzerling, John H.
    Hampton, Carnell J.
    Robinson, Myra
    Bright, Megan
    Moeller, Benjamin J.
    Ruiz, Justin
    Prabhu, Roshan
    Burri, Stuart H.
    Foster, Ryan D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (05): : 48 - 55
  • [23] Toward Distributed Conduction of Large-Scale Studies in Radiation Therapy and Oncology: Open-Source System Integration Approach
    Skripcak, Tomas
    Just, Uwe
    Simon, Monique
    Buettner, Daniel
    Luehr, Armin
    Baumann, Michael
    Krause, Mechthild
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (05) : 1397 - 1403
  • [24] Open-source, small-animal magnetic resonance-guided focused ultrasound system
    Poorman, Megan E.
    Chaplin, Vandiver L.
    Wilkens, Ken
    Dockery, Mary D.
    Giorgio, Todd D.
    Grissom, William A.
    Caskey, Charles F.
    JOURNAL OF THERAPEUTIC ULTRASOUND, 2016, 4
  • [25] Real-time liver tracking algorithm based on LSTM and SVR networks for use in surface-guided radiation therapy
    Guangyu Wang
    Zhibin Li
    Guangjun Li
    Guyu Dai
    Qing Xiao
    Long Bai
    Yisong He
    Yaxin Liu
    Sen Bai
    Radiation Oncology, 16
  • [26] Surface guided radiation therapy with an innovative open-face mask and mouth bite: patient motion management in brain stereotactic radiotherapy
    Xuemei Chen
    Lu Liu
    Yajuan Wang
    Xiaotong Huang
    Weixun Cai
    Xiaodong Rong
    Liuwen Lin
    Jindi Liu
    Xiaobo Jiang
    Clinical and Translational Oncology, 2024, 26 : 424 - 433
  • [27] Intrafraction Motion in Surface-Guided Breast Radiation Therapy and its Implications on a Single Planning Target Volume Margin Strategy
    Malone, Ciaran
    Ryan, Samantha
    Nicholson, Jill
    Mcardle, Orla
    Brennan, Sinead
    Mccavana, Pat
    Mcclean, Brendan
    Duane, Frances
    PRACTICAL RADIATION ONCOLOGY, 2025, 15 (01) : e63 - e71
  • [28] Real-time liver tracking algorithm based on LSTM and SVR networks for use in surface-guided radiation therapy
    Wang, Guangyu
    Li, Zhibin
    Li, Guangjun
    Dai, Guyu
    Xiao, Qing
    Bai, Long
    He, Yisong
    Liu, Yaxin
    Bai, Sen
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [29] Evaluation of initial patient setup methods for breast cancer between surface-guided radiation therapy and laser alignment based on skin marking in the Halcyon system
    Kang, Seonghee
    Jin, Hyeongmin
    Chang, Ji Hyun
    Jang, Bum-Sup
    Shin, Kyung Hwan
    Choi, Chang Heon
    Kim, Jung-in
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [30] Patient-Reported Outcomes-Guided Adaptive Radiation Therapy for Head and Neck Cancer
    Weppler, Sarah
    Quon, Harvey
    Schinkel, Colleen
    Yarschenko, Adam
    Barbera, Lisa
    Harjai, Nabhya
    Smith, Wendy
    FRONTIERS IN ONCOLOGY, 2021, 11