Outcomes of olecranon fractures in adolescents: comparison of tension band wiring and Herbert screw fixations

被引:2
作者
Yang, Weiwei [1 ]
Zhang, Xintao [1 ]
Sun, Dong [1 ]
Jin, Shaobin [1 ]
Chen, Junfei [1 ]
Li, Yang [1 ]
机构
[1] Shandong Univ, Dept Pediat Surg, Qilu Hosp, Jinan, Shandong, Peoples R China
关键词
children; olecranon fracture; Herbert screw fixation; epiphyseal growth plate; tension band wiring; COMPRESSION SCREWS; KIRSCHNER WIRES; CHILDREN;
D O I
10.3389/fped.2023.1269628
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Purpose: Olecranon fracture is considered intra-articular when there is obvious displacement or an irregular articular surface. Such fractures should be reduced and fixed via surgery. No clear indications regarding the surgical technique to be adopted exist. Therefore, this study aimed to compare the outcomes of tension band wiring (TBW) and Herbert screw fixations for olecranon fractures.Methods: We retrospectively analyzed the clinical data of 29 children with olecranon fractures. They were divided into the tension band wiring and Herbert screw groups. We assessed early epiphyseal closure and maximum length of the ulna using radiography. Patients were clinically evaluated using the average QuickDASH score.Results: Both groups had good radiological outcomes. Herbert screws demonstrated advantages in terms of bleeding, operative time, intraoperative blood loss, surgery duration, and particularly the QuickDASH score (1.57 vs. 4.18, p < 0.05). Complications, including needle loosening and bursitis, occurred in five cases in the TBW group. Six cases had premature physis plate closure, and no difference was observed in limb length at 6 months after surgery.Conclusion: Compared with TBW, Hebert screws demonstrated better clinical outcomes and lesser postoperative complications in the treatment of ulnar olecranon fractures in children. However, long-term follow-up is required to assess the effects of screws on the ulnar physis plate and ulna length.
引用
收藏
页数:7
相关论文
共 50 条
[31]   Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones [J].
Gruszka, Dominik ;
Arand, Charlotte ;
Greenfield, Julia ;
Nowak, Tobias E. ;
Kuechle, Raphael ;
Kuhn, Sebastian ;
Rommens, Pol M. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (12) :1651-1658
[32]   Surgical technique in tension band wiring method for selected comminuted olecranon fractures [J].
Okamoto, Michio ;
Namba, Jiro ;
Kuriyama, Kohji ;
Miyamura, Satoshi ;
Yokoi, Hiroyuki ;
Yamamoto, Koji .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (02) :237-242
[33]   Tension band wiring in olecranon fractures: the myth of technical simplicity and osteosynthetical perfection [J].
Marco M. Schneider ;
Tobias E. Nowak ;
Leonard Bastian ;
Jan C. Katthagen ;
Jörg Isenberg ;
Pol M. Rommens ;
Lars P. Müller ;
Klaus J. Burkhart .
International Orthopaedics, 2014, 38 :847-855
[34]   Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones [J].
Dominik Gruszka ;
Charlotte Arand ;
Julia Greenfield ;
Tobias E. Nowak ;
Raphael Kuechle ;
Sebastian Kuhn ;
Pol M. Rommens .
Archives of Orthopaedic and Trauma Surgery, 2017, 137 :1651-1658
[35]   Tension band wiring in olecranon fractures: the myth of technical simplicity and osteosynthetical perfection [J].
Schneider, Marco M. ;
Nowak, Tobias E. ;
Bastian, Leonard ;
Katthagen, Jan C. ;
Isenberg, Joerg ;
Rommens, Pol M. ;
Mueller, Lars P. ;
Burkhart, Klaus J. .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) :847-855
[36]   Comminuted Olecranon Fractures (Mayo IIB): Is Dynamic Tension Band Wiring Enough? [J].
Esper, Garrett W. ;
Herbosa, Christopher G. ;
Moses, Michael J. ;
Egol, Kenneth A. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (02) :96-101
[37]   Hook plate fixation and tension band wiring in the treatment of Mayo type II olecranon fractures [J].
Zhang, Jianyu ;
Zhang, Xigong ;
Hua, Kehan ;
Chen, Chen ;
Gong, Maoqi ;
Zha, Yejun ;
Jiang, Xieyuan .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01)
[38]   Biomechanical comparison for different configurations of tension band wiring techniques in treating an olecranon fracture [J].
Wu, CC ;
Tai, CL ;
Shih, CH .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 48 (06) :1063-1067
[39]   Locked Tension Band Wiring: A Modified Technique for Olecranon Fractures—A Multicenter Study Comparing Clinical Outcomes and Complications with Conventional Methods [J].
Yutaro Kuwahara ;
Yasuhiko Takegami ;
So Mitsuya ;
Katsuhiro Tokutake ;
Kenichi Yamauchi ;
Shiro Imagama .
Indian Journal of Orthopaedics, 2023, 57 :2024-2030
[40]   Comparison of the efficacy of the tension band wiring with eyelet wire versus anatomical locking plate fixation for the treatment of displaced olecranon fractures [J].
Shimura, Haruhiko ;
Nimura, Akimoto ;
Fujita, Koji ;
Kaburagi, Hidetoshi .
JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (03)