Case Series of Silver Oxide-Containing Hydroxyapatite Coating in Antibacterial Cementless Total Hip Arthroplasty: Clinical Results of 50 Cases at 5-Year Follow-Up

被引:4
作者
Kawano, Shunsuke [1 ,3 ]
Ueno, Masaya [2 ]
Fujii, Masanori [2 ]
Mawatari, Daisuke [2 ]
Mawatari, Masaaki [2 ]
机构
[1] Saga Univ, Fac Med, Res Ctr Arthroplasty, Saga, Japan
[2] Saga Univ, Fac Med, Dept Orthopaed Surg, Saga, Japan
[3] Saga Univ, Fac Med, Res Ctr Arthroplasty, Nabeshima 5-1-1, Saga 8498501, Japan
来源
ARTHROPLASTY TODAY | 2023年 / 19卷
关键词
Anti -bacterial agents; Prosthesis -related infections; Silver; Arthroplasty; Replacement; Hip; PERIPROSTHETIC JOINT INFECTION; IN-VIVO ANTIBACTERIAL; COATED MEGAPROSTHESES; KNEE ARTHROPLASTY; STEM; EXPERIENCE; RELEASE; BURDEN;
D O I
10.1016/j.artd.2022.10.017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Prosthetic joint infection, which is caused by implant treatment, is a severe complication. Consequently, silver-containing hydroxyapatite (Ag-HA)-coated implants have been developed to prevent prosthetic joint infection by combining Ag with HA. The Ag-HA-coated total hip prosthesis, which combines the antibacterial activity of Ag and the osteoconductivity of HA, is the first antibacterial cementless total hip prosthesis worldwide. This study aimed to evaluate the short-term outcomes of total hip arthroplasty (THA) with Ag-HA-coated implants.Methods: Overall, 50 hips with various disabling hip diseases and postoperative infection risks that underwent a primary THA using an Ag-HA total hip prosthesis were enrolled. The patients included 37 women (41 hips) and 8 men (9 hips), and the mean age at the time of surgery was 77 years. The clinical outcomes and hip function before and at 5 years postoperatively were measured using the Japanese Orthopaedic Association hip score. Implant stability was assessed, and postoperative complications were also examined. Results: The Japanese Orthopaedic Association score increased in all cases and improved from 41 to 86 points after the THA (P < .001). Radiography revealed no implant failure. Dislocation and deep vein thrombosis also occurred in 1 case each. However, there were no adverse reactions associated with Ag, and argyria was not observed in any case. Additionally, none of the patients experienced infection following the surgery.Conclusions: Silver-containing hydroxyapatite-coated implants significantly enhanced patients' daily activities without any adverse effects on the human body attributed to Ag, and they are expected to reduce postoperative infections.(c) 2022 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页数:6
相关论文
共 43 条
  • [1] Silver oxide-containing hydroxyapatite coating has in vivo antibacterial activity in the rat tibia
    Akiyama, Takayuki
    Miyamoto, Hiroshi
    Yonekura, Yutaka
    Tsukamoto, Masatsugu
    Ando, Yoshiki
    Noda, Iwao
    Sonohata, Motoki
    Mawatari, Masaaki
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (08) : 1195 - 1200
  • [2] Effect of Bacterial Media on the Evaluation of the Antibacterial Activity of a Biomaterial Containing Inorganic Antibacterial Reagents or Antibiotics
    Ando, Yoshiki
    Miyamoto, Hiroshi
    Noda, Iwao
    Miyaji, Fumiaki
    Shimazaki, Takafumi
    Yonekura, Yutaka
    Miyazaki, Masaki
    Mawatari, Masaaki
    Hotokebuchi, Takao
    [J]. BIOCONTROL SCIENCE, 2010, 15 (01) : 15 - 19
  • [3] Calcium phosphate coating containing silver shows high antibacterial activity and low cytotoxicity and inhibits bacterial adhesion
    Ando, Yoshiki
    Miyamoto, Hiroshi
    Noda, Iwao
    Sakurai, Nobuko
    Akiyama, Tomonori
    Yonekura, Yutaka
    Shimazaki, Takafumi
    Miyazaki, Masaki
    Mawatari, Masaaki
    Hotokebuchi, Takao
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2010, 30 (01): : 175 - 180
  • [4] Vancomycin covalently bonded to titanium alloy prevents bacterial colonization
    Antoci, Valentin, Jr.
    King, Samuel B.
    Jose, Binoy
    Parvizi, Javad
    Zeiger, Allen R.
    Wickstrom, Eric
    Freeman, Theresa A.
    Cornposto, Russell J.
    Ducheyne, Paul
    Shapiro, Irving M.
    Hickok, Noreen J.
    Adams, Christopher S.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2007, 25 (07) : 858 - 866
  • [5] Infection after total hip arthroplasty - The avon experience
    Blom, AW
    Taylor, AH
    Pattison, G
    Whitehouse, S
    Bannister, GC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (07): : 956 - 959
  • [6] Bouts BA, 1999, Argyria N Engl J Med, V340, P1554, DOI [10.1056/NEJM199905203402006, DOI 10.1056/NEJM199905203402006]
  • [7] A short-term follow-up study of a surgeon-customised fully-coated hydroxyapatite femoral stem using a nation-wide joint registry
    Dave, Aneesh
    Jang, Bob
    Bruce, Warwick
    [J]. JOURNAL OF ORTHOPAEDICS, 2016, 13 (02) : 90 - 94
  • [8] de la Riviere AB, 2000, J HEART VALVE DIS, V9, P123
  • [9] POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS
    ENGH, CA
    BOBYN, JD
    GLASSMAN, AH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01): : 45 - 55
  • [10] First Clinical Experience With Thermal-Sprayed Silver Oxide-Containing Hydroxyapatite Coating Implant
    Eto, Shuichi
    Kawano, Shunsuke
    Someya, Shinsuke
    Miyamoto, Hiroshi
    Sonohata, Motoki
    Mawatari, Masaaki
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (07) : 1498 - 1503