Evaluation of measurement accuracy of wearable devices for heart rate variability

被引:3
|
作者
Li, Xiangchen [1 ]
Song, Yuting [2 ]
Wang, Huang [1 ]
Su, Xinyu [3 ]
Wang, Mengyao [4 ]
Li, Jing [5 ,7 ]
Ren, Zhiqiang [6 ]
Zhong, Daidi [5 ]
Huang, Zhiyong [4 ]
机构
[1] China Inst Sport Sci, Beijing 100061, Peoples R China
[2] Qingdao Univ, Sch Nursing, Qingdao 266021, Peoples R China
[3] Beijing Sport Univ, Sch Sport Sci, Beijing 100084, Peoples R China
[4] Chongqing Univ, Sch Microelect & Commun Engn, Chongqing 400044, Peoples R China
[5] Chongqing Univ, Bioengn Coll, Chongqing 400044, Peoples R China
[6] Natl Sports Technol Innovat Ctr Beijing Co Ltd, Beijing 100061, Peoples R China
[7] Chinese Acad Sci, Shenzhen Inst Adv Technol, Shenzhen 518063, Peoples R China
关键词
PANIC DISORDER; RISK; ASSOCIATION; DEPRESSION; ANXIETY; INFANT;
D O I
10.1016/j.isci.2023.108128
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper proposed a method based on heart rate variability (HRV) for evaluating the accuracy of wearable devices in measuring heart rate. HRV refers to the variation in time intervals between successive heartbeats, widely used in many fields such as clinical and sports fields. Wearable devices such as Electrocardiogram (ECG) electrode patches have gained popularity due to their portability and ease of use. However, they can be prone to measurement interference caused by environmental noise, human respiration, etc. The proposed method consists of four main components: selection of "gold standard measurement devices", identification of HRV measurement metrics, construction of an HRV evaluation framework, and quantification of measurement errors. The method is validated through simulated experiments using ECG patches. The evaluation framework and quantification model established in this method have significant implications in establishment of industry standards and diagnosis of diseases in clinical practice.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Measurement latency significantly contributes to reduced heart rate measurement accuracy in wearable devices
    Støve M.P.
    Holm R.S.
    Kjaersgaard A.S.
    Duncker K.
    Jensen M.R.
    Larsen B.T.
    Journal of Medical Engineering and Technology, 2020, 44 (03): : 125 - 132
  • [2] THE EFFECT OF SKIN TONE ON ACCURACY OF HEART RATE MEASUREMENT IN WEARABLE DEVICES: A SYSTEMATIC REVIEW
    Koerber, Daniel
    Khan, Shawn
    Shamsheri, Tahmina
    Kirubarajan, Abirami
    Mehta, Sangeeta
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 1990 - 1990
  • [3] Measurement and evaluation of the autonomic nervous system balance by a wearable analyzer of heart rate variability
    Yanagihara, Nobuyuki
    Satoh, Noriaki
    Yamane, Chika
    Mitsumoto, Masamune
    Niimi, Tomoko
    Seki, Meikan
    Goto, Yukio
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2016, 130 (03) : S188 - S188
  • [4] Assessing Accuracy of Wrist-Worn Wearable Devices in Measurement of Paroxysmal Supraventricular Tachycardia Heart Rate
    Hwang, Jongmin
    Kim, Jun
    Choi, Kee-Joon
    Cho, Min Soo
    Nam, Gi-Byoung
    Kim, You-Ho
    KOREAN CIRCULATION JOURNAL, 2019, 49 (05) : 437 - 445
  • [5] Heart Rate Variability Analysis With Wearable Devices: Influence of Artifact Correction Method on Classification Accuracy for Emotion Recognition
    Cosoli, Gloria
    Poli, Angelica
    Scalise, Lorenzo
    Spinsante, Susanna
    2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021), 2021,
  • [6] Reliability Evaluation of R-R Interval Measurement Status for Time Domain Heart Rate Variability Analysis with Wearable ECG Devices
    Eguchi, Kana
    Aoki, Ryosuke
    Yoshida, Kazuhiro
    Yamada, Tomohiro
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1307 - 1311
  • [7] Accuracy of Heart Rate and Respiratory Rate Measurements Using Two Types of Wearable Devices
    Takahashi, Yusuke
    Okura, Kazuki
    Minakata, Shin
    Watanabe, Motoyuki
    Hatakeyama, Kazutoshi
    Chida, Satoaki
    Saito, Kimio
    Matsunaga, Toshiki
    Shimada, Yoichi
    PROGRESS IN REHABILITATION MEDICINE, 2022, 7
  • [8] A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults
    Miller, Dean J.
    Sargent, Charli
    Roach, Gregory D.
    SENSORS, 2022, 22 (16)
  • [9] STATE OF PLAY OF WEARABLE DEVICES FOR THE MEASUREMENT OF HEART RATE: A SYSTEMATIC REVIEW OF THE ACCURACY OF WRIST-WORN TECHNOLOGIES
    Giggins, Oonagh M.
    Muggeridge, David
    HEART, 2019, 105 : A5 - A5
  • [10] Accuracy of Heart Rate Measurement with Wrist-Worn Wearable Devices in Various Skin Tones: a Systematic Review
    Daniel Koerber
    Shawn Khan
    Tahmina Shamsheri
    Abirami Kirubarajan
    Sangeeta Mehta
    Journal of Racial and Ethnic Health Disparities, 2023, 10 : 2676 - 2684