Condition optimization of eco-friendly RP-HPLC and MCR methods via Box-Behnken design and six sigma approach for detecting antibiotic residues

被引:16
作者
Alanazi, Tahani Y. A. [1 ]
Pashameah, Rami Adel [2 ]
Binsaleh, Ammena Y. [3 ]
Mohamed, Mahmoud A. [4 ]
Ahmed, Hoda A. [5 ]
Nassar, Hossam F. [6 ]
机构
[1] Univ Hail, Fac Sci, Chem Dept, POB 2440, Hail 81451, Saudi Arabia
[2] Umm Al Qura Univ, Fac Appl Sci, Dept Chem, Mecca 24230, Saudi Arabia
[3] Princess Nourah Bint Abdulrahman Univ, Coll Pharm, Dept Pharm Practice, POB 84428, Riyadh 11671, Saudi Arabia
[4] Hikma Pharmaceut Co, Bani Suwayf, Egypt
[5] Cairo Univ, Fac Sci, Dept Chem, Cairo 12613, Egypt
[6] Beni Suef Univ, Fac Post Grad Studies Adv Sci, Environm Sci & Ind Dev Dept, Bani Suwayf, Egypt
关键词
SOLID-PHASE EXTRACTION; CEPHALOSPORIN ANTIBIOTICS; CEFIXIME TRIHYDRATE; SPECTROPHOTOMETRIC DETERMINATION; LIQUID-CHROMATOGRAPHY; QUANTIFICATION; VALIDATION; CEPHALEXIN; BENZOATE; MILK;
D O I
10.1038/s41598-023-40010-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A precise, Eco-friendly, and highly sensitive RP-HPLC method was employed using quality-by-design principles to concurrently identify cephalexin and cefixime residues in the manufacturing machines using a hypersil BDS C18 column (250 x 4.6 mm, 5 mu m) at wavelength 254 nm. The Box-Behnken design was applied to obtain the best chromatographic conditions with the fewest possible trials. Three independent factors viz organic composition, flow rate, and pH were used to assess their effects on the responses' resolution and retention time. Overlay plot and desirability functions were implemented to predict responses of the high resolution and relatively short retention time using a mobile phase composed of acidic water: acetonitrile (85:15, v/v) at pH 4.5 adjusted by phosphoric acid with a flow rate of 2.0 mL/min. The spectral overlapping of the drugs was successfully resolved by the mean centering ratio (MCR) spectra approach at 261 nm and 298 nm for cephalexin and cefixime, respectively. Good linearity results were obtained for the suggested HPLC and MCR methods over the concentration range of (0.05-10 ppm) and (5-30 ppm) with a detection limit of 0.003, 0.004, 0.26, and 0.23 ppm, and quantitation limits of 0.008, 0.013, 0.79, and 0.68 ppm for cephalexin and cefixime, respectively, with a correlation coefficient of >= 0.9998 and good swab recovery results of 99-99.5%. A process capability index was accomplished for chemical and micro results, illustrating that both are extremely capable. The suggested method was effectively validated using ICH recommendations.
引用
收藏
页数:28
相关论文
共 62 条
[1]  
Adem ASAN., 2022, J. Turk. Chem. Soc. Sect. A, V9, P483
[2]   Mean centering of ratio spectra as a new spectrophotometric method for the analysis of binary and ternary mixtures [J].
Afkhami, A ;
Bahram, M .
TALANTA, 2005, 66 (03) :712-720
[3]   Spectrophotometric determination of certain cephalosporins using ferrihydroxamate method [J].
Agbaba, D ;
Eric, S ;
KarljikovicRajic, K ;
Vladimirov, S ;
ZivanovStakic, D .
SPECTROSCOPY LETTERS, 1997, 30 (02) :309-319
[4]   Validation of an HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface of pharmaceutical manufacturing equipments [J].
Akl, Magda A. ;
Ahmed, Mona A. ;
Ramadan, Ahmed .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (02) :247-252
[5]  
Al-falluji Mustafa Mohammed, 2022, AIP Conference Proceedings, DOI 10.1063/5.0121113
[6]  
Ali SM., 2015, World J. Anal. Chem, V3, P21, DOI 10.12691/wjac-3-1A-5
[7]  
[Anonymous], 2014, WHO Technical Report Series, P986
[8]  
[Anonymous], 2023, The United States pharmacopeia 43. National formulary 38, DOI [10.31003/USPNF_M14280_02_01, DOI 10.31003/USPNF_M14280_02_01]
[9]   Green Analytical Chemistry [J].
Armenta, S. ;
Garrigues, S. ;
de la Guardia, M. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (06) :497-511
[10]  
Azmi Syed Najmul Hejaz, 2013, J Pharm Anal, V3, P248, DOI 10.1016/j.jpha.2012.12.009