Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography

被引:4
|
作者
Dong, Jing [1 ]
Yao, Jinhan [2 ]
Chang, Shuimiao [2 ]
Kanclerz, Piotr [3 ,4 ]
Khoramnia, Ramin [5 ]
Wang, Xiaogang [2 ]
机构
[1] Shanxi Med Univ, Dept Ophthalmol, Hosp 5, Taiyuan 030001, Peoples R China
[2] Shanxi Med Univ, Shanxi Eye Hosp, Taiyuan 030002, Peoples R China
[3] Hyge Clin, PL-80286 Gdansk, Poland
[4] Univ Helsinki, Helsinki Retina Res Grp, Helsinki 00014, Finland
[5] Heidelberg Univ, Dept Ophthalmol, David J Apple Int Lab Ocular Pathol, D-69120 Heidelberg, Germany
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 05期
关键词
angle-to-angle; anterior chamber intraocular lens; sclera spur-to-sclera spur; swept-source optical coherence tomography; white-to-white; implantable collamer lens; IMPLANTABLE COLLAMER LENS; WHITE-TO-WHITE; ANTERIOR-CHAMBER DEPTH; INTRAOCULAR-LENS; SCLERAL SPUR; OPTIMIZATION; VAULT;
D O I
10.3390/medicina59050899
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To investigate the iridocorneal angle-to-angle (ATA), sclera spur-to-sclera spur (STS), and white-to-white (WTW) ocular diameters and their potential influence on anterior chamber intraocular lens (ACIOL) and implantable collamer lens (ICL) sizing in Chinese subjects by using a swept-source optical coherence tomography system (SS-OCT). Design: A retrospective, observational, cross-sectional study. Methods: In 60 right eyes (60 subjects), the ATA, STS, and WTW were measured in six axes (0 degrees-180 degrees, 30 degrees-210 degrees, 60 degrees-240 degrees, 90 degrees-270 degrees, 120 degrees-300 degrees, and 150 degrees-330 degrees) using SS-OCT. The ACIOL and ICL sizes were calculated based on horizontal and vertical axes anterior segment data. A paired sample t-test was used to test the differences in each parameter across the six axes, the potential difference between each pair of parameters in a given axis, and the artificial lens size difference between the horizontal and vertical directions. Pearson's correlation analysis was used to determine the potential correlation between age and AL, WTW, STS, and ATA distances. Results: ATA and STS were the longest on the vertical and shortest on the horizontal axis, while WTW was similar on both axes. These three parameters differed only in the vertical axis (F = 4.910, p = 0.008). ATA and STS were by 0.23 +/- 0.08 mm (p = 0.005) and 0.21 +/- 0.08 mm wider (p = 0.010) than WTW, respectively. ICL size was 0.27 +/- 0.23 mm smaller when based on the horizontal than on the vertical axis parameters (p < 0.001), while ACIOL remained similar (p = 0.709). Age correlated negatively and axial length positively with all measured values. ATA, STS, and WTW correlated positively in the same axis (all p < 0.001). Conclusions: ATA and STS were longer in the vertical than in the horizontal direction, while WTW measurements remained similar. ATA and STS diameters more accurately depicted anatomic relationships for phakic IOL sizing than WTW.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Ocular biometry with swept-source optical coherence tomography
    Montes-Mico, Robert
    Pastor-Pascual, Francisco
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (06) : 802 - 814
  • [2] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [3] Evaluation of the Cortical Vitreous Using Swept-Source Optical Coherence Tomography in Normal Eyes
    Park, Seung Hun
    Lee, Jung Wook
    Lee, Min Ji
    Lee, Ju Hyang
    Song, In Seok
    Lee, Byung Ro
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (04): : 595 - 600
  • [4] Evaluation of the effect of ocular dominance on macular microcirculation via swept-source optical coherence tomography angiography
    Karakucuk, Yalcin
    Eker, Serhat
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2024, 49
  • [5] Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
    Ma, Shan
    Li, Cheng
    Sun, Jing
    Yang, Jun
    Wen, Kai
    Chen, Xi-Teng
    Zhao, Fang-Yu
    Gao, Rong-Yu
    Tian, Fang
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (08) : 1437 - 1446
  • [6] Analysis of cariogenic biofilms by using a swept-source optical coherence tomography in vitro
    Tabata, Tomoko
    Nakagawa, Hisaichi
    Matin, Khairul
    Otsuki, Masayuki
    Aoki, Akira
    Sumi, Yasunori
    Shimada, Yasushi
    ARCHIVES OF ORAL BIOLOGY, 2024, 165
  • [7] Evaluation of biometric indicators of anterior segment parameters after ICL implantation by swept-source optical coherence tomography
    Chuhao Tang
    Tong Sun
    Zhengze Sun
    Hongyu Duan
    Yilin Liu
    Lu Zhao
    Wenlong Li
    Linbo Bian
    Hong Qi
    BMC Ophthalmology, 23
  • [8] Evaluation of biometric indicators of anterior segment parameters after ICL implantation by swept-source optical coherence tomography
    Tang, Chuhao
    Sun, Tong
    Sun, Zhengze
    Duan, Hongyu
    Liu, Yilin
    Zhao, Lu
    Li, Wenlong
    Bian, Linbo
    Qi, Hong
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [9] Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry
    Gao, Rongrong
    Chen, Hao
    Savini, Giacomo
    Miao, Yaxin
    Wang, Xiaorui
    Yang, Jing
    Zhao, Weiqi
    Wang, Qinmei
    Huang, Jinhai
    SCIENTIFIC REPORTS, 2017, 7
  • [10] Error rate of automated choroidal segmentation using swept-source optical coherence tomography
    Kong, Mingui
    Eo, Doo Ri
    Han, Gyule
    Park, Sung Yong
    Ham, Don-Il
    ACTA OPHTHALMOLOGICA, 2016, 94 (06) : E427 - E431