New perspectives for the therapeutic drug monitoring of tacrolimus: Quantification in volumetric DBS based on an automated extraction and LC-MS/MS analysis

被引:6
|
作者
Rose, Gauthier [1 ]
Tafzi, Naima [1 ]
El Balkhi, Souleiman [1 ,2 ,3 ]
Rerolle, Jean-philippe [2 ,3 ,4 ]
Debette-Gratien, Marilyne [2 ,3 ,5 ]
Marquet, Pierre [1 ,2 ,3 ]
Saint-Marcoux, Franck [1 ,2 ,3 ]
Monchaud, Caroline [1 ,2 ,3 ,6 ]
机构
[1] CHU Limoges, Serv Pharmacol toxicol & pharmacovigilance, Limoges, France
[2] Univ Limoges, SERM UMR 1248 Pharmacol & Transplantat, Limoges, France
[3] FHU SUPORT, Limoges, France
[4] CHU Limoges, Serv Nephrol dialyse & transplantat, Limoges, France
[5] CHU Limoges, Serv Hepato gastroenterol & Nutr, Limoges, France
[6] CHU Limoges, Serv pharmacol toxicol & pharmacovigilance, INSERM UMR 1248, Ctr Biol & Rech Sante, 1248, 2 Ave Martin Luther King, F-87042 Limoges, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2023年 / 1223卷
关键词
Tacrolimus; Therapeutic drug monitoring; Volumetric dried blood spots; LC-MS/MS; Automated extraction; CYCLOSPORINE-A; BLOOD; HEMATOCRIT; CAPILLARY;
D O I
10.1016/j.jchromb.2023.123721
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Volumetric microsampling devices have been developed for home-based capillary blood sampling and are now increasingly proposed for the therapeutic drug monitoring (TDM) of immunosuppressive drugs. Our objective was to validate a LC-MS/MS method for tacrolimus quantification based on both a manual and an automated extraction of dried blood spots (DBS) collected with a volumetric microsampling device. DBS collection was performed by placing a drop of whole blood (WB) pre-spiked with tacrolimus onto a sealing film and placing the hemaPEN (R) device (Trajan Scientific and Medical, Melbourne, Australia) into the drop according to the device specifications. Tacrolimus was quantified using a fully automatic preparation module connected to a LCMS system (CLAM-3020 (R) and LCMS-8060 (R), Shimadzu, Marne-la-Vallee, France). The method was validated analytically and clinically in accordance with the EMA and IATDMCT guidelines. The method was linear from 1 to 100 mu g/L. Within-and between-run accuracy and precision fulfilled the validation criteria (biases and imprecision <15% or 20% for the lower limit of quantification). No hematocrit effect, matrix effect or carry-over was observed. No selectivity issue was identified and dilution integrity was confirmed. Tacrolimus in DBS was stable for 14 days at room temperature and +4 degrees C, and for 72h at +60 degrees C. There was a good correlation between tacrolimus concentrations measured in WB and in DBS of 20 kidney and liver transplant recipients (r=0.93 and 0.87, for manual and automated extraction respectively). A method for tacrolimus measurement in DBS collected with volumetric micro-sampling device, based on a fully automated process from pre-treatment to LC-MS/MS analysis was developed and validated according to analytical and clinical criteria. This performing sampling and analytical procedure opens the perspective of an easier, faster and more efficient TDM of tacrolimus for patients, clinicians and laboratories.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] LC-MS/MS assay for the therapeutic drug monitoring of perampanel in children with drug-resistant epilepsy
    Dai, Hao-ran
    Hu, Ya-hui
    Long, Jia-yi
    Xia, Ying
    Guo, Hong-li
    Xu, Jing
    Ding, Xuan-sheng
    Chen, Jing
    Lu, Xiao-peng
    Chen, Feng
    ACTA CHROMATOGRAPHICA, 2023, 35 (02) : 149 - 160
  • [42] Dried blood spot LC-MS/MS quantification of voclosporin in renal transplant recipients using volumetric dried blood spot sampling
    Metscher, E.
    Meziyerh, S.
    Arends, E. J.
    Teng, Y. K. O.
    de Vries, A. P. J.
    Swen, J. J.
    Moes, D. J. A. R.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 255
  • [43] Quantification of Tacrolimus in Human Skin Samples and Ointment by LC-MS
    Goebel, Alexandra S. B.
    Wohlrab, Johannes
    Neubert, Reinhard H. H.
    CHROMATOGRAPHIA, 2009, 70 (3-4) : 581 - 584
  • [44] Easy and fast LC-MS/MS determination of lidocaine and MEGX in plasma for therapeutic drug monitoring in neonates with seizures
    ter Weijden, E.
    van den Broek, M. P. H.
    Ververs, F. F. T.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 881-82 : 111 - 114
  • [45] A LC-MS/MS method for therapeutic drug monitoring of sorafenib, regorafenib and their active metabolites in patients with hepatocellular carcinoma
    Iacuzzi, Valentina
    Zanchetta, Martina
    Gagno, Sara
    Poetto, Ariana Soledad
    Orleni, Marco
    Marangon, Elena
    Guardascione, Michela
    Foltran, Luisa
    Posocco, Bianca
    Toffoli, Giuseppe
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 187
  • [46] Development and validation of an integrated LC-MS/MS assay for therapeutic drug monitoring of five PARP-inhibitors
    Bruin, M. A. C.
    de Vries, N.
    Lucas, L.
    Rosing, H.
    Huitema, A. D. R.
    Beijnen, J. H.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1138 (1138):
  • [47] Practical Approach of New LC-MS/MS Method for Monitoring Tacrolimus in Whole Blood of Patients After Kidney Transplantation
    Bodnar-Broniarczyk, M.
    Czaplicka, K.
    Pawinski, T.
    Majchrzak, J.
    Durlik, M.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 731 - 731
  • [48] A Novel LC-MS/MS Method for Therapeutic Drug Monitoring of Baricitinib in Plasma of Pediatric Patients
    Cafaro, Alessia
    Baiardi, Giammarco
    Pigliasco, Federica
    Barco, Sebastiano
    Mattioli, Francesca
    Volpi, Stefano
    Caorsi, Roberta
    Gattorno, Marco
    Cangemi, Giuliana
    THERAPEUTIC DRUG MONITORING, 2024, 46 (01) : 67 - 72
  • [49] Development and application of solid phase microextraction tips (SPME LC tips) method for therapeutic drug monitoring of gefitinib by LC-MS/MS
    Rodrigues, Leonardo Costalonga
    Lima, Lilian de Araujo
    Berlinck, Debora Zorron
    Morau, Mariana Vieira
    Perroud Junior, Mauricio Wesley
    Moriel, Patricia
    Costa, Jose Luiz
    GREEN ANALYTICAL CHEMISTRY, 2024, 11
  • [50] Solid phase extraction and LC-MS/MS quantification of ibandronate in human plasma
    Moustapha, Moustapha E.
    Abdel-Gawad, Sherif A.
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2020, 19 (06) : 1295 - 1302