B1 Field inhomogeneity correction for qDESS T2 mapping: application to rapid bilateral knee imaging

被引:0
|
作者
Barbieri, Marco [1 ]
Watkins, Lauren E. [1 ,2 ]
Mazzoli, Valentina [1 ]
Desai, Arjun D. [1 ,3 ]
Rubin, Elka [1 ]
Schmidt, Andrew [1 ]
Gold, Garry Evan [1 ,2 ]
Hargreaves, Brian Andrew [1 ,2 ,3 ]
Chaudhari, Akshay Sanjay [1 ,4 ]
Kogan, Feliks [1 ]
机构
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA USA
[3] Stanford Univ, Dept Elect Engn, Stanford, CA USA
[4] Stanford Univ, Dept Biomed Data Sci, Stanford, CA USA
来源
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE | 2023年 / 36卷 / 05期
关键词
QMRI; QDESS; T-2; mapping; B-1; correction; Bilateral knee imaging; STEADY-STATE DESS; DOUBLE-ECHO; IN-VIVO; ARTICULAR-CARTILAGE; RELAXATION-TIMES; T2; SEQUENCE; MRI; OPTIMIZATION; T-1-RHO;
D O I
10.1007/s10334-023-01094-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose T-2 mapping is a powerful tool for studying osteoarthritis (OA) changes and bilateral imaging may be useful in investigating the role of between- knee asymmetry in OA onset and progression. The quantitative double-echo in steady-state (qDESS) can provide fast simultaneous bilateral knee T-2 and high-resolution morphometry for cartilage and meniscus. The qDESS uses an analytical signal model to compute T-2 relaxometry maps, which require knowledge of the flip angle (FA). In the presence of B (1) inhomogeneities, inconsistencies between the nominal and actual FA can affect the accuracy of T (2) measurements. We propose a pixel-wise B-1 correction method for qDESS T-2 mapping exploiting an auxiliary B-1 map to compute the actual FA used in the model. Methods The technique was validated in a phantom and in vivo with simultaneous bilateral knee imaging. T-2 measurements of femoral cartilage (FC) of both knees of six healthy participants were repeated longitudinally to investigate the association between T-2 variation and B-1. Results The results showed that applying the B-1 correction mitigated T-2 variations that were driven by B-1 inhomogeneities. Specifically, T-2 left-right symmetry increased following the B-1 correction ( rho(c) = 0.74 > rho(c) = 0.69). Without the B 1 correction, T 2 values showed a linear dependence with B-1. The linear coefficient decreased using the B-1 correction (from 24.3 +/- 1.6 ms to 4.1 +/- 1.8) and the correlation was not statistically significant after the application of the Bonferroni correction (p value > 0.01). Conclusion The study showed that B-1 correction could mitigate variations driven by the sensitivity of the qDESS T-2 mapping method to B-1, therefore, increasing the sensitivity to detect real biological changes. The proposed method may improve the robustness of bilateral qDESS T 2 mapping, allowing for an accurate and more efficient evaluation of OA pathways and pathophysiology through longitudinal and cross-sectional studies.
引用
收藏
页码:711 / 724
页数:14
相关论文
共 50 条
  • [31] The influences of walking, running and stair activity on knee articular cartilage: Quantitative MRI using T1 rho and T2 mapping
    Chen, Meng
    Qiu, Lin
    Shen, Si
    Wang, Fei
    Zhang, Jing
    Zhang, Cici
    Liu, Sirun
    PLOS ONE, 2017, 12 (11):
  • [32] Comparison of a 28-channel receive array coil and quadrature volume coil for morphologic imaging and T2 mapping of knee cartilage at 7T
    Chang, Gregory
    Wiggins, Graham C.
    Xia, Ding
    Lattanzi, Riccardo
    Madelin, Guillaume
    Raya, Jose G.
    Finnerty, Matthew
    Fujita, Hiroyuki
    Recht, Michael P.
    Regatte, Ravinder R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (02) : 441 - 448
  • [33] Data-Driven Retrospective Correction of B1 Field Inhomogeneity in Fast Macromolecular Proton Fraction and R1 Mapping
    Yarnykh, Vasily L.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (12) : 3473 - 3484
  • [34] B1 Mapping of Short T2* Spins Using a 3D Radial Gradient Echo Sequence
    Kobayashi, Naoharu
    Garwood, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) : 1689 - 1699
  • [35] Evaluation of the Articular Cartilage of the Knee Joint: Value of Adding a T2 Mapping Sequence to a Routine MR Imaging Protocol
    Kijowski, Richard
    Blankenbaker, Donna G.
    del Rio, Alejandro Munoz
    Baer, Geoffrey S.
    Graf, Ben K.
    RADIOLOGY, 2013, 267 (02) : 503 - 513
  • [36] Longitudinal Analysis of Knee Articular Cartilage Degeneration After Anterior Cruciate Ligament Reconstruction: Comparison of T1rho and T2 Mapping
    Toguchi, Kaoru
    Watanabe, Atsuya
    Horii, Manato
    Watanabe, Shotaro
    Itoh, Ryu
    Sakamoto, Takuya
    Murata, Yasuaki
    Ohtori, Seiji
    Sasho, Takahisa
    CARTILAGE, 2024,
  • [37] 3D magnetic resonance fingerprinting for rapid simultaneous T1, T2, and T1ρ volumetric mapping of human articular cartilage at 3 T
    Sharafi, Azadeh
    Zibetti, Marcelo V. W.
    Chang, Gregory
    Cloos, Martijn
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2022, 35 (12)
  • [38] B1 Mapping for Bias-Correction in Quantitative T1 Imaging of the Brain at 3T Using Standard Pulse Sequences
    Boudreau, Mathieu
    Tardif, Christine L.
    Stikov, Nikola
    Sled, John G.
    Lee, Wayne
    Pike, G. Bruce
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (06) : 1673 - 1682
  • [39] Initial experience with synthetic MRI of the knee at 3T: comparison with conventional T1 weighted imaging and T2 mapping
    Park, Sunghoon
    Kwack, Kyu-Sung
    Lee, Young Ju
    Gho, Sung-Min
    Lee, Hyun Young
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1080)
  • [40] Bilateral cartilage T2 mapping 9 years after Mega-OATS implantation at the knee: a quantitative 3T MRI study
    Jungmann, P. M.
    Brucker, P. U.
    Baum, T.
    Link, T. M.
    Foerschner, F.
    Minzlaff, P.
    Banke, I. J.
    Saier, T.
    Imhoff, A. B.
    Rummeny, E. J.
    Bauer, J. S.
    OSTEOARTHRITIS AND CARTILAGE, 2015, 23 (12) : 2119 - 2128