共 50 条
B1 Field inhomogeneity correction for qDESS T2 mapping: application to rapid bilateral knee imaging
被引:0
|作者:
Barbieri, Marco
[1
]
Watkins, Lauren E.
[1
,2
]
Mazzoli, Valentina
[1
]
Desai, Arjun D.
[1
,3
]
Rubin, Elka
[1
]
Schmidt, Andrew
[1
]
Gold, Garry Evan
[1
,2
]
Hargreaves, Brian Andrew
[1
,2
,3
]
Chaudhari, Akshay Sanjay
[1
,4
]
Kogan, Feliks
[1
]
机构:
[1] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Bioengn, Stanford, CA USA
[3] Stanford Univ, Dept Elect Engn, Stanford, CA USA
[4] Stanford Univ, Dept Biomed Data Sci, Stanford, CA USA
来源:
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE
|
2023年
/
36卷
/
05期
关键词:
QMRI;
QDESS;
T-2;
mapping;
B-1;
correction;
Bilateral knee imaging;
STEADY-STATE DESS;
DOUBLE-ECHO;
IN-VIVO;
ARTICULAR-CARTILAGE;
RELAXATION-TIMES;
T2;
SEQUENCE;
MRI;
OPTIMIZATION;
T-1-RHO;
D O I:
10.1007/s10334-023-01094-y
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose T-2 mapping is a powerful tool for studying osteoarthritis (OA) changes and bilateral imaging may be useful in investigating the role of between- knee asymmetry in OA onset and progression. The quantitative double-echo in steady-state (qDESS) can provide fast simultaneous bilateral knee T-2 and high-resolution morphometry for cartilage and meniscus. The qDESS uses an analytical signal model to compute T-2 relaxometry maps, which require knowledge of the flip angle (FA). In the presence of B (1) inhomogeneities, inconsistencies between the nominal and actual FA can affect the accuracy of T (2) measurements. We propose a pixel-wise B-1 correction method for qDESS T-2 mapping exploiting an auxiliary B-1 map to compute the actual FA used in the model. Methods The technique was validated in a phantom and in vivo with simultaneous bilateral knee imaging. T-2 measurements of femoral cartilage (FC) of both knees of six healthy participants were repeated longitudinally to investigate the association between T-2 variation and B-1. Results The results showed that applying the B-1 correction mitigated T-2 variations that were driven by B-1 inhomogeneities. Specifically, T-2 left-right symmetry increased following the B-1 correction ( rho(c) = 0.74 > rho(c) = 0.69). Without the B 1 correction, T 2 values showed a linear dependence with B-1. The linear coefficient decreased using the B-1 correction (from 24.3 +/- 1.6 ms to 4.1 +/- 1.8) and the correlation was not statistically significant after the application of the Bonferroni correction (p value > 0.01). Conclusion The study showed that B-1 correction could mitigate variations driven by the sensitivity of the qDESS T-2 mapping method to B-1, therefore, increasing the sensitivity to detect real biological changes. The proposed method may improve the robustness of bilateral qDESS T 2 mapping, allowing for an accurate and more efficient evaluation of OA pathways and pathophysiology through longitudinal and cross-sectional studies.
引用
收藏
页码:711 / 724
页数:14
相关论文