Effect of solution acidity on cytochrome c conformations of alternating current electrospray ionization mass spectrometry

被引:0
|
作者
Chen, Hsiao-Ping [1 ]
Li, Cheng-Han [1 ]
Chang, Yut-Zu [1 ]
Hsieh, Wen-Shan [1 ]
Wang, Shau-Chun [1 ,2 ]
机构
[1] Natl Chung Cheng Univ, Dept Chem & Biochem, Chiayi 621, Taiwan
[2] Natl Chung Cheng Univ, Ctr Nano Biodetect Technol Res, Chiayi 621, Taiwan
关键词
alternating current; electrospray ionization; mass spectrometry; protein; WATER;
D O I
10.1002/jccs.202300042
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper reports notable observations regarding the ion charge states of thermally stable cytochrome c, generated using an alternating current (AC) electrospray ionization (ESI) device. An AC ESI sprayer entrains low-mobility ions to accumulate at the meniscus cone tip prior to the ejection of detached aerosols to produce analyte ions. Therefore, as the solvent acidity varies, protein ions entrained in the AC cone tip are found to change conformation less significantly compared with those in the direct current (DC) cone. We acquired the AC ESI mass spectra of cytochrome c at pH range from 2 to 4. Unlike the DC ESI mass spectra showing clear conformation changes due to denaturing, the AC spectra indicated that only partial denaturing occurs even at extremely acidic pH 2. More native cytochrome c in lower charge states therefore remained. Moreover, with a solvent mixture of aqueous buffer and acetonitrile (70:30), partially denatured cytochrome c was still preserved at pH 2 by using AC ESI. Completely denatured proteins are observed at pH 2 by using DC ESI.
引用
收藏
页码:1348 / 1354
页数:7
相关论文
共 50 条
  • [1] A Comparison of Alternating Current and Direct Current Electrospray Ionization for Mass Spectrometry
    Sarver, Scott A.
    Chetwani, Nishant
    Dovichi, Norman J.
    Go, David B.
    Gartner, Carlos A.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (04) : 524 - 529
  • [2] Reaction Dynamics and Solution Chemistry of Polyoxometalates by Electrospray Ionization Mass Spectrometry
    Ohlin, C. Andre
    CHEMISTRY-AN ASIAN JOURNAL, 2012, 7 (02) : 262 - 270
  • [3] Electrospray ionization mass spectrometry of ginsenosides
    Miao, XS
    Metcalfe, CD
    Hao, CY
    March, RE
    JOURNAL OF MASS SPECTROMETRY, 2002, 37 (05): : 495 - 506
  • [4] Electrospray ionization mass spectrometry of metalloporphyrins
    Vandell, VE
    Limbach, PA
    JOURNAL OF MASS SPECTROMETRY, 1998, 33 (03): : 212 - 220
  • [5] Studies on Icariin by electrospray ionization mass spectrometry
    Dou, JP
    Liu, ZQ
    Liu, SY
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2004, 25 (05): : 837 - 840
  • [6] Characterization of macromolecules by electrospray ionization mass spectrometry
    Prokai, L
    INTERNATIONAL JOURNAL OF POLYMER ANALYSIS AND CHARACTERIZATION, 2001, 6 (3-4) : 379 - 391
  • [7] Observation of micelle solution of decyltrimethylammonium bromide by electrospray ionization mass spectrometry
    Nohara, D
    Bitoh, M
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (12): : 1434 - 1437
  • [8] Coupling Electrochemistry with Probe Electrospray Ionization Mass Spectrometry
    Cai, Yi
    Liu, Pengyuan
    Held, Michael A.
    Dewald, Howard D.
    Chen, Hao
    CHEMPHYSCHEM, 2016, 17 (08) : 1104 - 1108
  • [9] Determination of binding selectivities by electrospray ionization mass spectrometry
    Brodbelt, JS
    Kempen, E
    Reyzer, M
    STRUCTURAL CHEMISTRY, 1999, 10 (03) : 213 - 220
  • [10] Electrospray ionization mass spectrometry with wooden tips: A review
    Hu, Bin
    Yao, Zhong-Ping
    ANALYTICA CHIMICA ACTA, 2022, 1209