A novel monolithic Zn/Cr-LDH composite for in-tube solid-phase microextraction of acidic herbicides from water samples

被引:4
|
作者
Kefayati, Hanieh [1 ]
Yamini, Yadollah [1 ]
Nasrollahi, Seyedeh Sara [1 ]
机构
[1] Tarbiat Modares Univ, Fac Sci, Dept Chem, POB 4115-175, Tehran, Iran
关键词
In -tube solid-phase microextraction; Layered double hydroxide; Monolithic column; Chlorophenoxy acetic acid herbicides; Gas chromatography-mass spectrometry; PERFORMANCE LIQUID-CHROMATOGRAPHY; DERIVATIZATION; PYROLYSIS;
D O I
10.1016/j.jfca.2024.106019
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A monolithic composite based on Zn/Cr-layer double hydroxide (Zn/Cr-LDH) was introduced for in-tube solidphase microextraction (IT-SPME) of chlorophenoxy acetic acid (CPAs) herbicides. A polymeric monolith composed of methacrylic acid (MAA) and Zn/Cr-LDH was simply prepared in a polypropylene tube by in situ polymerization method. 2,4-Dichlorophenoxyacetic acid (2,4-D) and 4-chloro-2-methylphenoxyacetic acid (MCPA) were identified and measured using gas chromatography coupled to mass spectrometry (GC-MS). The fabricated composite was characterized by X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), and Fourier transform infrared spectroscopy (FT-IR). The extraction efficiency was enhanced by optimizing crucial factors, such as salt concentration, sample solution pH, extraction, and desorption conditions. Under the optimum conditions, low detection limits (LODs) were obtained in the range of 0.01-0.05 ng mL-1 with good linearity in the range of 0.1-500 ng mL-1 and coefficient of determinations (R2) better than 0.9975. The inter and intra-assay precisions (RSD%, for n = 3) were achieved in the range of 7.1-8.2% and 6.8-7.9%, respectively. The monolithic composite displayed satisfying extraction performance and effective clean-up of CPAs from water samples.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] An in-tube aptamer/gold nanoparticles coated capillary solid-phase microextraction for separation of adenosine in serum and urine samples
    Ma, Yanxia
    Hao, Lixian
    Lin, Xiangjun
    Liu, Xiaofei
    Qiu, Xinni
    Zhang, Xiaoting
    Hu, Xiaogang
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1611
  • [42] Erratum to: Novel polystyrene/antibody nanoparticle-coated capillary for immunoaffinity in-tube solid-phase microextraction
    Bei Xu
    Shuai Cheng
    Xianhua Wang
    Dongmei Wang
    Liang Xu
    Analytical and Bioanalytical Chemistry, 2015, 407 : 5547 - 5547
  • [43] Sodium hyaluronate-functionalized urea-formaldehyde monolithic column for hydrophilic in-tube solid-phase microextraction of melamine
    Wang, Jiabin
    Jiang, Nan
    Cai, Zhengmiao
    Li, Wenbang
    Li, Jianhua
    Lin, Xucong
    Xie, Zenghong
    You, Lijun
    Zhang, Qiqing
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1515 : 54 - 61
  • [44] Novel synthesized attapulgite nanoparticles-based hydrophobic monolithic column for in-tube solid-phase microextraction of thiosildenafil, pseudovardenafil, and norneosildenafil in functional foods
    Dong, Lubei
    Chen, Yihui
    Chen, Shubing
    Hou, Chunyan
    Wang, Shangyou
    Xuan, Rongrong
    Fang, Keyi
    Wang, Tingting
    Zhang, Lihua
    Zhang, Yukui
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (07) : 1871 - 1882
  • [45] Using cobalt/chromium layered double hydroxide nano-sheets as a novel packed in-tube solid phase microextraction sorbent for facile extraction of acidic pesticides from water samples
    Asiabi, Hamid
    Yamini, Yadollah
    Shamsayei, Maryam
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (12) : 9935 - 9944
  • [46] In-Tube Solid-Phase Microextraction and Liquid Chromatography Using a Monolithic Column for the Selective Determination of Residual Ethylenediamine in Industrial Cationic Polymers
    Prieto-Blanco, M. C.
    Lopez-Mahia, P.
    Campins-Falco, P.
    ANALYTICAL CHEMISTRY, 2009, 81 (14) : 5827 - 5832
  • [47] In-situ preparation of β-cyclodextrin-crosslinked polymer coated glass fiber for in-tube solid-phase microextraction of polycyclic aromatic hydrocarbons from water samples
    Zhang, Yijun
    Wang, Yingying
    Li, Chun-Xiang
    Chen, Xiaowen
    Lu, Zhenyu
    Zhang, Mingxia
    Zhu, Xiaohui
    Yu, Yunjiang
    MICROCHEMICAL JOURNAL, 2023, 194
  • [48] Highly sensitive analysis of substituted aniline compounds in water samples by using oxidized multiwalled carbon nanotubes as an in-tube solid-phase microextraction medium
    Liu, Xiao-Yan
    Jia, Yong-Sheng
    Zhang, Hai-Xia
    Liu, Man-Cang
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1212 (1-2) : 10 - 15
  • [49] Indirect analysis of urea herbicides from environmental water using solid-phase microextraction
    Berrada, H
    Font, G
    Moltó, JC
    JOURNAL OF CHROMATOGRAPHY A, 2000, 890 (02) : 303 - 312
  • [50] Molecularly imprinted polypyrrole@CuO nanocomposite as an in-tube solid-phase microextraction coating for selective extraction of carbamazepine from biological samples
    Kefayati, Hanieh
    Yamini, Yadollah
    Shamsayei, Maryam
    Abdi, Siamak
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 204