Enhancing the brain MRI at ultra-high field systems using a meta-array structure

被引:8
作者
Alipour, Akbar [1 ,2 ,5 ,6 ]
Seifert, Alan C. [1 ,2 ]
Delman, Bradley N. [3 ]
Hof, Patrick R. [2 ,4 ]
Fayad, Zahi A. [1 ,2 ]
Balchandani, Priti [1 ,2 ]
机构
[1] Icahn Sch Med Mt Sinai, BioMed Engn & Imaging Inst, New York, NY USA
[2] Icahn Sch Med Mt Sinai, Friedman Brain Inst, New York, NY USA
[3] Icahn Sch Med Mt Sinai, Dept Diagnost Mol & Intervent Radiol, New York, NY USA
[4] Icahn Sch Med Mt Sinai, Nash Family Dept Neurosci, New York, NY 10029 USA
[5] Icahn Sch Med Mt Sinai, BioMed Engn & Imaging Inst, 1470 Madison Ave, 1st Floor, New York, NY 10029 USA
[6] Icahn Sch Med Mt Sinai, Friedman Brain Inst, 1470 Madison Ave, 1st Floor, New York, NY 10029 USA
关键词
brain MRI; high-permittivity material; meta-array; radiofrequency; split-ring resonator; ultra-high-field; 7; T; SENSOR;
D O I
10.1002/mp.16801
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe main advantage of ultra-high field (UHF) magnetic resonance neuroimaging is theincreased signal-to-noise ratio (SNR) compared with lower field strength imaging. However, the wavelength effect associated with UHF MRI results in radiofrequency (RF) inhomogeneity, compromising whole brain coverage for many commercial coils. Approaches to resolving this issue of transmit field inhomogeneity include the design of parallel transmit systems (PTx), RF pulse design, and applying passive RF shimming such as high dielectric materials. However, these methods have some drawbacks such as unstable material parameters of dielectric pads, high-cost, and complexity of PTx systems. Metasurfaces are artificial structures with a unique platform that can control the propagation of the electromagnetic (EM) waves, and they are very promising for engineering EM device. Implementation of meta-arrays enhancing MRI has been explored previously in several studies.PurposeThe aim of this study was to assess the effect of new meta-array technology on enhancing the brain MRI at 7T. A meta-array based on a hybrid structure consisting of an array of broadside-coupled split-ring resonators and high-permittivity materials was designed to work at the Larmor frequency of a 7 Tesla (7T) MRI scanner. When placed behind the head and neck, this construct improves the SNR in the region of the cerebellum,brainstem and the inferior aspect of the temporal lobes.MethodsNumerical electromagnetic simulations were performed to optimize the meta-array design parameters and determine the RF circuit configuration. The resultant transmit-efficiency and signal sensitivity improvements were experimentally analyzed in phantoms followed by healthy volunteers using a 7T whole-body MRI scanner equipped with a standard one-channel transmit, 32-channel receive head coil. Efficacy was evaluated through acquisition with and without the meta-array using two basic sequences: gradient-recalled-echo (GRE) and turbo-spin-echo (TSE).ResultsExperimental phantom analysis confirmed two-fold improvement in the transmit efficiency and 1.4-fold improvement in the signal sensitivity in the target region. In vivo GRE and TSE images with the meta-array in place showed enhanced visualization in inferior regions of the brain, especially of the cerebellum, brainstem, and cervical spinal cord.ConclusionAddition of the meta-array to commonly used MRI coils can enhance SNR to extend the anatomical coverage of the coil and improve overall MRI coil performance. This enhancement in SNR can be leveraged to obtain a higher resolution image over the same time slot or faster acquisition can be achieved with same resolution. Using this technique could improve the performance of existing commercial coils at 7T for whole brain and other applications.
引用
收藏
页码:7606 / 7618
页数:13
相关论文
共 51 条
[1]   Evidence of traumatic brain injury in headbutting bovids [J].
Ackermans, Nicole L. ;
Varghese, Merina ;
Williams, Terrie M. ;
Grimaldi, Nicholas ;
Selmanovic, Enna ;
Alipour, Akbar ;
Balchandani, Priti ;
Reidenberg, Joy S. ;
Hof, Patrick R. .
ACTA NEUROPATHOLOGICA, 2022, 144 (01) :5-26
[2]   Metamaterial magnetoinductive lens performance as a function of field strength [J].
Algarin, Jose M. ;
Freire, Manuel J. ;
Breuer, Felix ;
Behr, Volker C. .
JOURNAL OF MAGNETIC RESONANCE, 2014, 247 :9-14
[3]  
Alipour A., 2021, ENHANCED ULTRAHIGH F
[4]   Improvement of magnetic resonance imaging using a wireless radiofrequency resonator array [J].
Alipour, Akbar ;
Seifert, Alan C. ;
Delman, Bradley N. ;
Robson, Philip M. ;
Shrivastava, Raj ;
Hof, Patrick R. ;
Adriany, Gregor ;
Fayad, Zahi A. ;
Balchandani, Priti .
SCIENTIFIC REPORTS, 2021, 11 (01)
[5]   An inductively coupled ultra-thin, flexible, and passive RF resonator for MRI marking and guiding purposes: Clinical feasibility [J].
Alipour, Akbar ;
Gokyar, Sayim ;
Algin, Oktay ;
Atalar, Ergin ;
Demir, Hilmi Volkan .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) :361-370
[6]   Development of a distance-independent wireless passive RF resonator sensor and a new telemetric measurement technique for wireless strain monitoring [J].
Alipour, Akbar ;
Unal, Emre ;
Gokyar, Sayim ;
Demir, Hilmi Volkan .
SENSORS AND ACTUATORS A-PHYSICAL, 2017, 255 :87-93
[7]  
ASTM, 2011, F248211AASTMF248211A
[8]   An SRR based microwave absorber [J].
Bilotti, Filiberto ;
Nucci, Luca ;
Vegni, Lucio .
MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2006, 48 (11) :2171-2175
[9]   Signal-to-noise measurements in magnitude images from NMR phased arrays [J].
Constantinides, CD ;
Atalar, E ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :852-857
[10]   The future of ultra-high field MRI and fMRI for study of the human brain [J].
Duyn, Jeff H. .
NEUROIMAGE, 2012, 62 (02) :1241-1248