Automatic near real-time quality control tests for biofouling effect on measurement data

被引:2
|
作者
Skalvik, Astrid Marie [1 ]
Tengberg, Anders [2 ]
Froysa, Kjell-Eivind [3 ,4 ]
Bjork, Ranveig N. [4 ]
Saetre, Camilla [1 ]
机构
[1] Univ Bergen, Dept Phys & Technol, Bergen, Norway
[2] Aanderaa Data Instruments AS, Bergen, Norway
[3] Western Norway Univ Appl Sci, Dept Comp Sci Elect Engn & Math Sci, Haugesund, Norway
[4] NORCE Norwegian Res Ctr, Bergen, Norway
来源
关键词
biofouling; measurement; sensor; data quality; self-validation; SENSORS;
D O I
10.1109/OCEANSLimerick52467.2023.10244340
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
The reliability of water quality measurement is crucial for sustainable use of ocean resources, climate and ecosystem models, and industrial applications. However, measurement stations in remote locations face limitations in terms of power, communication, and maintenance, posing challenges for data quality. Even though some basic (near) real-time automatic tests are proposed in oceanographic measurement guidelines, time- and resource consuming Delayed Mode Quality Control is still required before using measurement data in forecasting, models, or decision- making. To design effective quality control tests for more autonomous sensors with self-validating capabilities in real-time, a good understanding of expected environmental effects or errors on sensor signals is necessary. This paper focuses on the effect of biofouling on the measurement of selected water quality parameters such as conductivity, oxygen, and turbidity. Biofouling remains a major issue despite research on biofouling protection and anti-biofouling sensor design. Biofouling growth on underwater sensors can increase measurement errors and uncertainty, result in shorter operation times, and require costly manual work related to retrieval, cleaning, and re-deployment. For some measurement technologies, biofouling can result in noise, while for others, it may cause systematic drift or delay signal exchange. Here, we propose quality control tests designed to automatically detect and assess the impact of biofouling on sensor signals. These tests are applied to measurement data sets with a known presence of biofouling from Austevoll (Norway). We comment on the challenges of designing tests and setting adequate thresholds. We show that a detailed understanding of biofouling effect on sensors is crucial for designing effective near real-time quality control procedures. Automatic, in-situ tests can save costs related to manual data quality control and increase data quality, thereby enabling well-informed decisions in ocean resource management, climate and ecosystem modeling, and industrial applications.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Quality control tools and digitalization of real-time data in sustainable manufacturing
    Menon, Akshay Pradeep
    Lahoti, Vedang
    Gunreddy, Neha
    Chadha, Utkarsh
    Selvaraj, Senthil Kumaran
    Nagalakshmi, R.
    Jayakumar, K.
    Karthikeyan, B.
    INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2022,
  • [22] Quality control data management with unity real-time in molecular virology
    Quinton, Mikayla
    Neil, Becky
    Mitchell, Sondra
    Mostafa, Heba H.
    JOURNAL OF CLINICAL VIROLOGY, 2024, 171
  • [23] REAL-TIME QUALITY-CONTROL OF STREAMFLOW DATA - A SIMULATION STUDY
    KRAJEWSKI, WF
    KRAJEWSKI, KL
    WATER RESOURCES BULLETIN, 1989, 25 (02): : 391 - 399
  • [24] A Real-Time Quality Control System Based on Manufacturing Process Data
    Duan, Gui-Jiang
    Yan, Xin
    IEEE ACCESS, 2020, 8 : 208506 - 208517
  • [25] Real-time measurement and control at JET experiment control
    Felton, R
    Joffrin, E
    Murari, A
    Zabeo, L
    Sartori, F
    Piccolo, F
    Farthing, J
    Budd, T
    Dorling, S
    McCullen, P
    Harling, J
    Dalley, S
    Goodyear, A
    Stephen, A
    Card, P
    Bright, M
    Lucock, R
    Jones, E
    Griph, S
    Hogben, C
    Beldishevski, M
    Buckley, M
    Davis, J
    Young, I
    Hemming, O
    Wheatley, M
    Heesterman, P
    Lloyd, G
    Walters, M
    Bridge, R
    Leggate, H
    Howell, D
    Zastrow, KD
    Giroud, C
    Coffey, I
    Hawkes, N
    Stamp, M
    Barnsley, R
    Edlington, T
    Guenther, K
    Gowers, C
    Popovichef, S
    Huber, A
    Ingesson, C
    Mazon, D
    Moreau, D
    Alves, D
    Sousa, J
    Riva, M
    Barana, O
    FUSION ENGINEERING AND DESIGN, 2005, 74 (1-4) : 561 - 566
  • [26] Quality Assurance/Quality Control of Real-Time Oceanographic Data Status and Implementation Efforts
    Bushnell, Mark
    OCEANS 2015 - MTS/IEEE WASHINGTON, 2015,
  • [27] Automatic near real-time flood detection using Suomi-NPP/VIIRS data
    Li, Sanmei
    Sun, Donglian
    Goldberg, Mitchell D.
    Sjoberg, Bill
    Santek, David
    Hoffman, Jay P.
    DeWeese, Mike
    Restrepo, Pedro
    Lindsey, Scott
    Holloway, Eric
    REMOTE SENSING OF ENVIRONMENT, 2018, 204 : 672 - 689
  • [28] Sensor data quality control - A challenge for real-time (Rig) data transmission and usage
    Mathis, W.
    Thonhauser, G.
    OIL GAS-EUROPEAN MAGAZINE, 2007, 33 (03): : 126 - 131
  • [29] REAL-TIME AUTOMATIC MESSAGE ACCOUNTING DATA TRANSPORT
    SHAFIK, E
    BASU, K
    ANNALES DES TELECOMMUNICATIONS-ANNALS OF TELECOMMUNICATIONS, 1994, 49 (1-2): : 75 - 79
  • [30] Quality Control Analysis in Real-time (QC-ART): A Tool for Real-time Quality Control Assessment of Mass Spectrometry-based Proteomics Data
    Stanfill, Bryan A.
    Nakayasu, Ernesto S.
    Bramer, Lisa M.
    Thompson, Allison M.
    Ansong, Charles K.
    Clauss, Therese R.
    Gritsenko, Marina A.
    Monroe, Matthew E.
    Moore, Ronald J.
    Orton, Daniel J.
    Piehowski, Paul D.
    Schepmoes, Athena A.
    Smith, Richard D.
    Webb-Robertson, Bobbie-Jo M.
    Metz, Thomas O.
    MOLECULAR & CELLULAR PROTEOMICS, 2018, 17 (09) : 1824 - 1836