Comparison of the two most commonly used gold-standard velocity monitoring devices (GymAware and T-Force) to assess lifting velocity during the free-weight barbell back squat exercise

被引:15
作者
Janicijevic, Danica [1 ,2 ]
Garcia-Ramos, Amador [3 ,4 ]
Luis Lamas-Cepero, Juan [3 ]
Garcia-Pinillos, Felipe [3 ,5 ]
Marcos-Blanco, Aitor [3 ]
Javier Rojas, Francisco [3 ]
Weakley, Jonathon [6 ,7 ]
Perez-Castilla, Alejandro [3 ]
机构
[1] Ningbo Univ, Affiliated Hosp, Res Acad Human Biomech, Med Sch, Ningbo, Peoples R China
[2] Univ Belgrade, Fac Sport & Phys Educ, Res Ctr, Belgrade, Serbia
[3] Univ Granada, Fac Sport Sci, Dept Phys Educ & Sport, Carretera Alfacar S-N, Granada 18011, Spain
[4] Univ Catolica Santisima Concepcion, Fac Educ, Dept Sports Sci & Phys Conditioning, Concepcion, Chile
[5] Univ La Frontera, Dept Phys Educ Sports & Recreat, Temuco, Chile
[6] Australian Campus Univ, Sch Behav & Hlth Sci, Brisbane, Qld, Australia
[7] Leeds Beckett Univ, Carnegie Appl Rugby Res CARR Ctr, Inst Sport Phys Act & Leisure, Leeds, W Yorkshire, England
关键词
linear position transducer; linear velocity transducer; reliability; validity; velocity-based training; MEASURE MOVEMENT VELOCITY; RELIABILITY; VALIDITY; POWER;
D O I
10.1177/17543371211029614
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study aimed to compare the reliability and agreement of mean velocity (MV) and maximal velocity (V-max) between the two velocity monitoring devices (GymAware vs T-Force) most commonly used in the scientific literature. Twenty resistance-trained males completed two testing sessions. The free-weight barbell back squat one-repetition maximum (1RM) was determined in the first session (125.0 +/- 24.2 kg; mean +/- standard deviation). The second session consisted of two blocks of 16 repetitions (six repetitions at 45% 1RM and 65% 1RM, and four repetitions at 85% 1RM). Half of the repetitions were performed with the GymAware on the left side of the barbell and the other half of the repetitions were performed on the right side of the barbell (opposite placement for the T-Force). MV and V-max were recorded simultaneously with the GymAware and T-Force. The overall reliability, which was calculated pooling together the data of three loads, did not differ between the T-Force (coefficient of variation (CV) = 5.28 +/- 1.79%) and GymAware (CV = 5.79 +/- 2.26%) (CVratio = 1.10), but the reliability was higher for V-max (CV = 5.08 +/- 1.79%) compared to MV (CV = 5.98 +/- 2.73%) (CVratio = 1.18). MV was significantly higher for the T-Force (p < 0.001, Delta = 4.42%), but no significant differences were detected between the devices for V-max (p = 0.455, Delta = 0.22%). These results support the use of both the GymAware and T-Force as gold-standards in studies designed to validate other velocity monitoring devices. However, systematic bias, albeit rather constant, exists for the magnitude of MV between the two devices.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 37 条
[1]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[2]   VALIDITY AND RELIABILITY OF THE PUSH WEARABLE DEVICE TO MEASURE MOVEMENT VELOCITY DURING THE BACK SQUAT EXERCISE [J].
Balsalobre-Fernandez, Carlos ;
Kuzdub, Matt ;
Poveda-Ortiz, Pedro ;
del Campo-Vecino, Juan .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (07) :1968-1974
[3]   Comparison of the Effects of Velocity-Based Training Methods and Traditional 1RM-Percent-Based Training Prescription on Acute Kinetic and Kinematic Variables [J].
Banyard, Harry G. ;
Tufano, James J. ;
Delgado, Jose ;
Thompson, Steve W. ;
Nosaka, Kazunori .
INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2019, 14 (02) :246-255
[4]   Reliability and Criterion Validity of the Assess2Perform Bar Sensei [J].
Beckham, George K. ;
Layne, Danielle K. ;
Kim, Steven B. ;
Martin, Eric A. ;
Perez, Benjamin G. ;
Adams, Kent J. .
SPORTS, 2019, 7 (11)
[5]   Validation of power measurement techniques in dynamic lower body resistance exercises [J].
Cormie, Prue ;
McBride, Jeffrey M. ;
McCaulley, Grant O. .
JOURNAL OF APPLIED BIOMECHANICS, 2007, 23 (02) :103-118
[6]   Reproducibility and Repeatability of Five Different Technologies for Bar Velocity Measurement in Resistance Training [J].
Courel-Ibanez, Javier ;
Martinez-Cava, Alejandro ;
Moran-Navarro, Ricardo ;
Escribano-Penas, Pablo ;
Chavarren-Cabrero, Javier ;
Gonzalez-Badillo, Juan Jost ;
Pallares, Jesus G. .
ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (07) :1523-1538
[7]   Validity and reliability of a linear positional transducer across commonly practised resistance training exercises [J].
Dorrell, Harry F. ;
Moore, Joseph M. ;
Smith, Mark F. ;
Gee, Thomas I. .
JOURNAL OF SPORTS SCIENCES, 2019, 37 (01) :67-73
[8]   Variability and progression in competitive performance of Paralympic swimmers [J].
Fulton, Sacha K. ;
Pyne, David ;
Hopkins, Will ;
Burkett, Brendan .
JOURNAL OF SPORTS SCIENCES, 2009, 27 (05) :535-539
[9]   Reliability and concurrent validity of the Velowin optoelectronic system to measure movement velocity during the free-weight back squat [J].
Garcia-Ramos, Amador ;
Perez-Castilla, Alejandro ;
Martin, Fernando .
INTERNATIONAL JOURNAL OF SPORTS SCIENCE & COACHING, 2018, 13 (05) :737-742
[10]   Differences in the Load-Velocity Profile Between 4 Bench-Press Variants [J].
Garcia-Ramos, Amador ;
Luis Pestana-Melero, Francisco ;
Perez-Castilla, Alejandro ;
Javier Rojas, Francisco ;
Haff, Guy Gregory .
INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2018, 13 (03) :326-331