Ultra-high sensitivity surface plasmon U-channel photonic crystal fiber for hemoglobin sensing

被引:10
作者
Dai, Tiantian [1 ]
Yan, Jiaquan [2 ]
Zhu, Wanlai [1 ]
Bian, Liang [1 ]
Yi, Zao [1 ,3 ,4 ]
Liu, Mengsi [3 ]
Tang, Bin [5 ]
Sun, Tangyou [6 ]
Li, Gongfa [7 ]
Yu, Zhenfang [1 ,8 ]
机构
[1] Southwest Univ Sci & Technol, Minist Educ, State Key Lab Environm Friendly Energy Mat, Joint Lab Extreme Condit Matter Properties,Key Lab, Mianyang 621010, Peoples R China
[2] Minjiang Univ, Coll Comp & Data Sci, Fujian Prov Key Lab Informat Proc & Intelligent Co, Fuzhou 350108, Peoples R China
[3] Yangtze Univ, Sch Phys & Optoelect Engn, Jingzhou 434023, Hubei, Peoples R China
[4] Jishou Univ, Sch Chem & Chem Engn, Jishou 416000, Peoples R China
[5] Changzhou Univ, Sch Microelect & Control Engn, Changzhou 213164, Peoples R China
[6] Guilin Univ Elect Technol, Guangxi Key Lab Precis Nav Technol & Applicat, Guilin 541004, Peoples R China
[7] Wuhan Univ Sci & Technol, Hubei Key Lab Mech Transmiss & Mfg Engn, Wuhan 430081, Peoples R China
[8] Sci Equipments Co, Chengdu 610015, Sichuan, Peoples R China
关键词
Photonic crystal fiber; U-channel sensor; Surface plasmon resonance (SPR); Surface plasmon polariton (SPP); Hemoglobin concentration sensing; REFRACTIVE-INDEX; BIOSENSOR;
D O I
10.1016/j.sna.2024.115053
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to increase the wavelength response range of the U-channel sensor, a numerical study has been conducted and then the sensing structure has been optimized. A sensor in photonic crystal fiber (PCF) is proposed in which a layer of titanium dioxide is coated on the surface of the U-channel and then coated with a gold film. These two different metal films are mainly used to control the Surface plasmon resonance (SPR) peak and the corresponding resonance wavelength, thus changing the sensor performance. Just below the metal layer are two special air holes on either side. They form a leakage window in the center. In the following sections, the effects of these variables on the sensor will be studied in detail by COMSOL. The modal transmission characteristics of this fiber optic sensor are analyzed in this paper. By analyzing the obtained loss spectrum, the energy variation in the surface plasmon polariton (SPP) mode and the influence of the core mode on the sensing performance of the fiber optic sensor presented, the general rule of the optimized PCF-SPR sensor is deduced. In addition, we can make subtle adjustments to the sensor to improve its sensitivity. We found with the refractive index (RI) ranging from 1.26 to 1.42, the maximum wavelength sensitivity is 7500 nm/RIU, which corresponds to a full width at half maximum (FWHM) of 11.83 nm,a figure of merit (FOM) of 634.1 RIU-1. In addition, we also have discussed the sensor and different concentrations of hemoglobin aqueous solution to detect its RI. It is evident from the results that the sensor demonstrates excellent sensitivity and a wide detection range, which is highly desirable for practical diagnostic purposes. The potential of this sensor for clinical trials and its application to medical diagnostics is promising. Compared with complex traditional methods, the PCF has obvious advantages such as clear structure, simple manufacture, high sensitivity and strong environmental adaptability. Moreover, it has the advantage of wide wavelength response range and has a clear development prospect in the field of biochemical sensing. It has foreseeable potential practical value.
引用
收藏
页数:11
相关论文
共 58 条
  • [1] Enhanced sensitivity of hemoglobin sensor using dual-core photonic crystal fiber
    Ayyanar, N.
    Khalil, Ahmed E.
    Hameed, Mohamed Farhat O.
    Raja, G. Thavasi
    Obayya, Salah S. A.
    [J]. OPTICAL AND QUANTUM ELECTRONICS, 2018, 50 (12)
  • [2] REFRACTIVE-INDEX OF SOME MAMMALIAN-TISSUES USING A FIBER OPTIC CLADDING METHOD
    BOLIN, FP
    PREUSS, LE
    TAYLOR, RC
    FERENCE, RJ
    [J]. APPLIED OPTICS, 1989, 28 (12): : 2297 - 2303
  • [3] Graphene photonic crystal fibre with strong and tunable light-matter interaction
    Chen, Ke
    Zhou, Xu
    Cheng, Xu
    Qiao, Ruixi
    Cheng, Yi
    Liu, Can
    Xie, Yadian
    Yu, Wentao
    Yao, Fengrui
    Sun, Zhipei
    Wang, Feng
    Liu, Kaihui
    Liu, Zhongfan
    [J]. NATURE PHOTONICS, 2019, 13 (11) : 754 - +
  • [4] Graphene Multi-Frequency Broadband and Ultra-Broadband Terahertz Absorber Based on Surface Plasmon Resonance
    Chen, Zihao
    Cai, Pinggen
    Wen, Qiye
    Chen, Hao
    Tang, Yongjian
    Yi, Zao
    Wei, Kaihua
    Li, Gongfa
    Tang, Bin
    Yi, Yougen
    [J]. ELECTRONICS, 2023, 12 (12)
  • [5] Terahertz narrowband perfect metasurface absorber based on micro-ring-shaped GaAs array for enhanced refractive index sensing
    Cheng, Yongzhi
    Qian, Yingjie
    Luo, Hui
    Chen, Fu
    Cheng, Zhengze
    [J]. PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES, 2023, 146
  • [6] Simple design of a six-band terahertz perfect metasurface absorber based on a single resonator structure
    Cheng, Yongzhi
    Zhao, Jingcheng
    [J]. PHYSICA SCRIPTA, 2022, 97 (09)
  • [7] Sensitive and In Situ Hemoglobin Detection Based on a Graphene Oxide Functionalized Microfiber
    Fang, Fang
    Li, Yanpeng
    Yang, Liuyang
    Li, Liangye
    Yan, Zhijun
    Sun, Qizhen
    [J]. NANOMATERIALS, 2020, 10 (12) : 1 - 11
  • [8] Dual ultrahigh-Q Fano Resonances of 3D gap metamaterials for slow light from ultraviolet to visible range
    Feng, Shu Ni Ao
    Wang, Yajun
    Fei, Shurui
    Yan, Zhendong
    Yu, Lili
    Chen, Jing
    Tang, Chaojun
    Liu, Fanxin
    [J]. OPTICS COMMUNICATIONS, 2023, 549
  • [9] Model function to calculate the refractive index of native hemoglobin in the wavelength range of 250-1100 nm dependent on concentration
    Friebel, M
    Meinke, M
    [J]. APPLIED OPTICS, 2006, 45 (12) : 2838 - 2842
  • [10] Design of Surface Plasmon Resonance-Based D-Type Double Open-Loop Channels PCF for Temperature Sensing
    Gao, Shuangyan
    Wei, Kaihua
    Yang, Hua
    Tang, Yongjian
    Yi, Zao
    Tang, Chaojun
    Tang, Bin
    Yi, Yougen
    Wu, Pinghui
    [J]. SENSORS, 2023, 23 (17)