Characterization of antigen presentation capability for neoantigen-based products using targeted LC-MS/MS method

被引:0
|
作者
Xiang, Nan [1 ,2 ]
Zhang, Kehua [2 ]
Zhao, Yinghua [3 ]
Xu, Chongfeng [2 ]
Zhang, Xiuqing [1 ]
Meng, Shufang [2 ]
机构
[1] Univ Chinese Acad Sci, Coll Life Sci, Beijing 100049, Peoples R China
[2] Natl Inst Food & Drug Control, Cell Collect & Res Ctr, 31 Huatuo St, Beijing, Peoples R China
[3] SCIEX China, 5F,Bldg 1,24 Jiuxianqiao Middle Rd, Beijing, Peoples R China
关键词
Mass spectrometry; Neoantigen Peptides; Antigen presentation; Sensitivity; Dendritic cells; T-CELLS; PEPTIDE; VACCINE; MELANOMA;
D O I
10.1016/j.jpba.2023.115886
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The generation of an immune response in neoantigen-based products relies on antigen presentation, which is closely analyzed by bioassays for T -cell functions such as tetramer or cytokine release. Mass spectrometry (MS) has the potential to directly assess the antigen -presenting capability of antigen -presenting cells (APCs), offering advantages such as speed, multi -target analysis, robustness, and ease of transferability. However, it has not been used for quality control of these products due to challenges in sensitivity, including the number of cells and peptide diversity. In this study, we describe the development and validation of an improved targeted LC-MS/MS method with high sensitivity for characterizing antigen presentation, which could be applied in the quality control of neoantigen-based products. The parameters for the extraction were carefully optimized by different short peptides. Highly sensitive targeted triple quadrupole mass spectrometry combined with ultra -high performance liquid chromatography (UHPLC) was employed using a selective ion monitoring mode (Multiple Reaction Monitoring, MRM). Besides, we successfully implemented robust quality control peptides to ensure the reliability and consistency of this method, which proved invaluable for different APCs. With reference to the guidelines from ICH Q2 (R2), M10, as well as considering the specific attributes of the product itself, we validated the method for selectivity, specificity, sensitivity, limit of detection (LOD), recovery rate, matrix effect, repeatability, and application in dendritic cells (DCs) associated with neoantigen-based products. The validation process yields satisfactory results. Combining this approach with T cell assays will comprehensively assess cell product quality attributes from physicochemical and biological perspectives.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Comparison of allergen quantification strategies for egg, milk, and peanut in food using targeted LC-MS/MS
    Xiong, Weili
    Parker, Christine H.
    Boo, Chelsea C.
    Fiedler, Katherine L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (23) : 5755 - 5766
  • [22] Targeted LC-MS/MS-based metabolomics and lipidomics on limited hematopoietic stem cell numbers
    Schoenberger, Katharina
    Mitterer, Michael
    Buescher, Joerg M.
    Cabezas-Wallscheid, Nina
    STAR PROTOCOLS, 2022, 3 (02):
  • [23] Uncovering the phenolic diversity of Guabiju fruit: LC-MS/MS-based targeted metabolomics approach
    Spinelli, Liziane, V
    Anzanello, Michel J.
    Santos, Rodrigo Areze da Silva
    Martins, Caroline Carboni
    Saggin, Justine Freo
    Da Silva, Magnolia Aparecida Silva
    Rodrigues, Eliseu
    FOOD RESEARCH INTERNATIONAL, 2023, 173
  • [24] Determination of cortisone and cortisol in human scalp hair using an improved LC-MS/MS-based method
    Mirzaian, Mina
    van Zundert, Sofie K. M.
    Schilleman, Wim F.
    Mohseni, Mostafa
    Kuckuck, Susanne
    van Rossum, Elisabeth F. C.
    van Schaik, Ron H. N.
    van den Berg, Sjoerd A. A.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (01) : 118 - 127
  • [25] Optimization of Ceramide Analysis Method Using LC-MS in Cosmetics
    Park, Su-Jin
    Yoo, Hee-Jin
    Kim, Duck-Hyun
    Park, Ji-Won
    Jeon, Eunji
    Mojumdar, Abhik
    Cho, Kun
    MASS SPECTROMETRY LETTERS, 2024, 15 (01) : 49 - 53
  • [26] A new multiresidue method for the determination of multiclass pesticides, degradation products and PCBs in water using LC-MS/MS and GC-MS(n) systems
    Charalampous, Angeliki C.
    Miliadis, George E.
    Koupparis, Michael A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2015, 95 (13) : 1283 - 1298
  • [27] LC, LC-MS/TOF and MSn studies for the separation, identification and characterization of degradation products of ritonavir
    Tiwari, Ravi N.
    Bonde, Chandrakant G.
    ANALYTICAL METHODS, 2011, 3 (07) : 1674 - 1681
  • [28] A Targeted LC-MS/MS Method for the Simultaneous Detection and Quantitation of Egg, Milk, and Peanut Allergens in Sugar Cookies
    Boo, Chelsea C.
    Parker, Christine H.
    Jackson, Lauren S.
    JOURNAL OF AOAC INTERNATIONAL, 2018, 101 (01) : 108 - 117
  • [29] Characterization of the Glycosylation Site of Human PSA Prompted by Missense Mutation using LC-MS/MS
    Song, Ehwang
    Hu, Yunli
    Hussein, Ahmed
    Yu, Chuan-Yih
    Tang, Haixu
    Mechref, Yehia
    JOURNAL OF PROTEOME RESEARCH, 2015, 14 (07) : 2872 - 2883
  • [30] Identification and LC-MS/MS-based analyses of technical enzymes in wheat flour and baked products
    Uhr, Linda
    Wieland, Phillis
    Homann, Thomas
    Huschek, Gerd
    Rawel, Harshadrai M.
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2016, 242 (02) : 247 - 257