Clinical evaluation of autonomous robotic-assisted full-arch implant surgery: A 1-year prospective clinical study

被引:7
作者
Xie, Rui [1 ,2 ,3 ,4 ]
Liu, Yuchen [1 ,2 ,3 ,4 ]
Wei, Hongbo [1 ,2 ,3 ,5 ]
Zhang, Tingmin [1 ,2 ,3 ,4 ]
Bai, Shizhu [1 ,2 ,3 ,4 ,6 ]
Zhao, Yimin [1 ,2 ,3 ,4 ,6 ]
机构
[1] State Key Lab Oral & Maxillofacial Reconstruct & R, Xian, Shaanxi, Peoples R China
[2] Natl Clin Res Ctr Oral Dis, Xian, Shaanxi, Peoples R China
[3] Shaanxi Key Lab Stomatol, Xian, Shaanxi, Peoples R China
[4] Fourth Mil Med Univ, Digital Ctr, Sch Stomatol, Xian, Shaanxi, Peoples R China
[5] Fourth Mil Med Univ, Sch Stomatol, Dept Oral Implants, Xian, Shaanxi, Peoples R China
[6] Fourth Mil Med Univ, Digital Ctr, Sch Stomatol, 145 Changle West Rd, Xian 710032, Peoples R China
关键词
accuracy; buccal bone thickness; computer-assisted implant surgery; dental implants; surgical robot; PLACEMENT;
D O I
10.1111/clr.14243
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This prospective clinical study aimed to evaluate the accuracy and 1-year clinical follow-up performance of dental implant placement with an autonomous dental implant robot (ADIR) system in full-arch implant surgery. Materials and Methods: Twelve patients with edentulous arches or final dentition received 102 implants using the ADIR system. Global platform deviation, global apex deviation, and global angular deviation between the planned and actual implants were calculated after surgery. Data were statistically analyzed for factors including jaws, implant positions, patient sequences, implant systems, and implant length. Surgery duration was recorded. Patients were followed for 3 months and 1 year after surgery. Periodontal parameters, buccal bone thickness (BBT), and facial vertical bone wall peak (IP-FC) were recorded. Results: Among the 102 implants, the mean (SD) global platform deviation, global apex deviation, and global angular deviation were 0.53 (0.19) mm, 0.58 (0.17) mm, and 1.83 (0.82)(degrees), respectively. The deviation differences between the mandible and maxilla did not show statistical significance (p > .05). No statistically significant differences were found for the jaws, implant positions, patient sequences, implant systems, and implant length to the deviations (p > .05). The periodontal parameters, the BBT, and IP-FC remained stable during 1-year follow-up. Conclusion: The ADIR system showed excellent positional accuracy. The 1-year follow-up after full-arch implant surgery indicated that the ADIR system could achieve promising clinical performance. Additional clinical evidence is requisite to furnish guidelines for the implementation of the ADIR system in full-arch implant surgery.
引用
收藏
页码:443 / 453
页数:11
相关论文
共 50 条
  • [41] Effects of Flapless Implant Surgery on Soft Tissue Profiles: A Prospective Clinical Study
    Lee, Du-Hyeong
    Choi, Byung-Ho
    Jeong, Seung-Mi
    Xuan, Feng
    Kim, Ha-Rang
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (04) : 324 - 329
  • [42] Digital Evaluation of Three Splinting Materials Used to Fabricate Verification Jigs for Full-Arch Implant Prostheses: A Comparative Study
    Papaspyridakos, Panos
    Kim, Yong-Jeong
    Finkelman, Matthew
    El-Rafie, Khaled
    Weber, Hans-Peter
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2017, 29 (02) : 102 - 109
  • [43] Immediate functional loading of TiOblast dental implants in full-arch edentulous mandibles: a 3-year prospective study
    De Bruyn, H.
    de Velde, T. Van
    Collaert, B.
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (07) : 717 - 723
  • [44] Pain Intensity and Its Objective Determinants Following Implant Surgery and Sinus Lifting: A 1-Year Prospective Study
    Atalay, B.
    Ramazanoglu, M.
    Tozan, E. N.
    Ozyuvaci, H.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2017, 20 (09) : 1139 - 1144
  • [45] Evaluation of the clinical safety and performance of a narrow diameter (2.9 mm) bone-level implant: a 1-year prospective single-arm multicenter study
    Walter, Christian
    Sagheb, Keyvan
    Blatt, Sebastian
    Klein, Marcus Oliver
    Herrmann, Jan
    Kleinheinz, Johannes
    Al-Nawas, Bilal
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)
  • [46] Immediate functional loading of TiOblast dental implants in full-arch edentulous maxillae: a 3-year prospective study
    Collaert, Bruno
    De Bruyn, Hugo
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (12) : 1254 - 1260
  • [47] CBCT analysis of the tissue thickness at immediate implant placement with contour augmentation in the maxillary anterior zone: a 1-year prospective clinical study
    Fujita, Yuya
    Nakano, Tamaki
    Ono, Shinji
    Shimomoto, Takuya
    Mizuno, Keiichiro
    Yatani, Hirofumi
    Ishigaki, Shoichi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [48] Prospective clinical evaluation of 201 direct laser metal forming implants: results from a 1-year multicenter study
    Carlo Mangano
    Francesco Mangano
    Jamil Awad Shibli
    Giuseppe Luongo
    Michele De Franco
    Francesco Briguglio
    Michele Figliuzzi
    Tammaro Eccellente
    Carmine Rapani
    Michele Piombino
    Aldo Macchi
    Lasers in Medical Science, 2012, 27 : 181 - 189
  • [49] Prospective clinical evaluation of 201 direct laser metal forming implants: results from a 1-year multicenter study
    Mangano, Carlo
    Mangano, Francesco
    Shibli, Jamil Awad
    Luongo, Giuseppe
    De Franco, Michele
    Briguglio, Francesco
    Figliuzzi, Michele
    Eccellente, Tammaro
    Rapani, Carmine
    Piombino, Michele
    Macchi, Aldo
    LASERS IN MEDICAL SCIENCE, 2012, 27 (01) : 181 - 189
  • [50] A 1-Year Prospective Clinical and Radiographic Study of Early-Loaded Bone Level Implants in the Posterior Maxilla
    Markovic, Aleksa
    Colic, Snjezana
    Scepanovic, Miodrag
    Misic, Tijana
    Dinic, Ana
    Bhusal, Dinesh Sharma
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (05) : 1004 - 1013