The Impact of Coronary Sinus Reducer on Arrhythmic Properties in Patients with Refractory Angina

被引:0
|
作者
Mrak, Miha [1 ,2 ]
Zlahtic, Tadej [1 ,2 ]
Starc, Vito [3 ]
Ivanovski, Maja [1 ,2 ]
Bunc, Matjaz [1 ,2 ]
Zizek, David [1 ,2 ]
机构
[1] Univ Med Ctr Ljubljana, Dept Cardiol, Ljubljana 1000, Slovenia
[2] Univ Ljubljana, Fac Med, Ljubljana 1000, Slovenia
[3] Univ Ljubljana, Inst Physiol, Fac Med, Ljubljana 1000, Slovenia
关键词
electrocardiogram; refractory angina; arrhythmia; coronary sinus reducer; VENTRICULAR-FIBRILLATION; DEVICE; OCCLUSION; ISCHEMIA; EFFICACY;
D O I
10.31083/j.rcm2412368
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Treatment with a coronary sinus reducer (CSR) is a new therapeutic option for refractory angina patients. Preclinical studies have shown antiarrhythmic properties of coronary sinus narrowing. The possible antiarrhythmic effect of CSR implantation is unknown. This study aimed to determine the possible antiarrhythmic effects of CSR implantation as assessed by high-resolution electrocardiogram (hrECG) parameters. Methods: 24 patients from the Crossroad study randomized to either CSR treatment (n = 12) or a sham procedure (n = 12) had hrECG recorded at baseline and after 6 months. T-peak and T-end interval (TpTe) defined as the time difference between the peak amplitude of the T wave and the global end of the T wave, spatial angle between QRS complex and T axis defined as the angle between the ventricular depolarization and repolarization vectors using maximal (QRSTP) and mean (QRSTM) vector amplitudes and spatial ventricular gradient (SVG) calculated as integral of ECG voltages over the entire QRST complex were analyzed. Additionally, we analyzed parameters of QT and heart rate variability using time and frequency domain. Results: At baseline, all analyzed parameters were comparable between both groups and heart rate remained constant. The intragroup analysis did not show any significant change in TpTe, QRSTP, QRSTM, SVG, QT, and heart rate variability at follow-up. Furthermore, intergroup comparison between CSR implantation and sham procedure also did not show any significant difference in the change of analyzed parameters. Conclusions: Compared to the sham procedure, CSR implantation did not demonstrate a significant impact on the arrhythmogenic substrate assessed with hrECG. Clinical
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The Efficacy of Coronary Sinus Reducer in Patients with Refractory Angina: A Systematic Review and Meta-Analysis
    Theofilis, Panagiotis
    Vlachakis, Panayotis K.
    Sagris, Marios
    Mantzouranis, Emmanouil
    Sakalidis, Athanasios
    Soulaidopoulos, Stergios
    Chasikidis, Christos
    Oikonomou, Evangelos
    Tsioufis, Konstantinos
    Tousoulis, Dimitris
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2024, 25 (03)
  • [32] Coronary sinus reducer device for the treatment of refractory angina: a single center experience
    Domingues, M. Sobral
    Carvalho, R.
    Pereira, J. Certo
    Madeira, S.
    Brito, J.
    Raposo, L.
    Teles, R.
    Almeida, M.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [33] Coronary Sinus Reducer device implantation: a new treatment for chronic refractory angina
    Giannini, Francesco
    Aurelio, Andrea
    Chieffo, Alaide
    GIORNALE ITALIANO DI CARDIOLOGIA, 2016, 17 (10) : 3S - 9S
  • [34] Effectiveness of Coronary Sinus Reducer for Treatment of Refractory Angina: A Meta-analysis
    Hochstadt, Aviram
    Itach, Tamar
    Merdler, Ilan
    Ghantous, Eihab
    Ziv-Baran, Tomer
    Leshno, Moshe
    Banai, Shmuel
    Konigstein, Maayan
    CANADIAN JOURNAL OF CARDIOLOGY, 2022, 38 (03) : 376 - 383
  • [35] Usefulness of Coronary Sinus Reducer Implantation for the Treatment of Chronic Refractory Angina Pectoris
    D'Amico, Gianpiero
    Giannini, Francesco
    Massussi, Mauro
    Tebaldi, Matteo
    Cafaro, Alessandro
    Ielasi, Alfonso
    Sgura, Fabio
    De Marco, Federico
    Stefanini, Giulio G.
    Ciardetti, Marco
    Versaci, Francesco
    Latini, Roberto A.
    Sacca, Salvatore
    Ghiringhelli, Sergio
    Picchi, Andrea
    Cerrito, Marco
    Gaspardone, Achille
    Tarantini, Giuseppe
    AMERICAN JOURNAL OF CARDIOLOGY, 2021, 139 : 22 - 27
  • [36] Coronary sinus Reducer device for the treatment of refractory angina: A multicenter initial experience
    Reis, Joao Ferreira
    Brizido, Catarina
    Madeira, Sergio
    Ramos, Ruben
    Almeida, Manuel
    Cacela, Duarte
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2023, 42 (05) : 413 - 420
  • [37] Percutaneous treatment for refractory angina with the coronary sinus Reducer: A multicenter initial experience
    da Silveira, Joao Brum
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2023, 42 (05) : 421 - 422
  • [38] Coronary sinus reducer implantation in the middle cardiac vein for the treatment of refractory angina
    D'Amico, Gianpiero
    Massussi, Mauro
    Fraccaro, Chiara
    Tarantini, Giuseppe
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (04) : 718 - 721
  • [39] The impact of coronary sinus narrowing on diastolic function in patients with refractory angina
    Szekely, Yishay
    Topilsky, Yan
    Bazan, Samuel
    Revivo, Miri
    Banai, Shmuel
    Konigstein, Maayan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 291 : 8 - 12
  • [40] First Experience with the Coronary Sinus Reducer System for the Management of Refractory Angina in Patients Without Obstructive Coronary Artery Disease
    Giannini, Francesco
    Baldetti, Luca
    Ielasi, Alfonso
    Ruparelia, Neil
    Ponticelli, Francesco
    Latib, Azeem
    Mitomo, Satoru
    Esposito, Antonio
    Palmisano, Anna
    Chieffo, Alaide
    Colombo, Antonio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B56 - B56