Research on the Coupling between High-voltage Cables and Low-voltage Cables in Electric Vehicles

被引:1
|
作者
Wang, Huihui [1 ]
Gao, Changsheng [2 ]
Han, Hongji [2 ]
Ren, Jie [1 ]
Zhang, Dan [1 ]
机构
[1] Beijing Jiaotong Univ, Electromagnet Compatibil Lab, Beijing, Peoples R China
[2] China FAW Grp Co Ltd, Elect & Elect Res Inst, Changcun, Peoples R China
关键词
electric vehicles; crosstalk; simulation; shielding;
D O I
10.1109/ICEAA57318.2023.10297767
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There are a lot of cables in electric vehicles, and cables layout is complex. The space inside an electric vehicle is small. Even if the high-voltage and low-voltage cables are not routed side by side, the electromagnetic emission from the high-voltage cables may affect the signals transmitted from the low-voltage cables in the same space. In this paper, the coupling between high and low voltage cables of a control device in an electric vehicle is studied, and the influence of different grounding conditions of high voltage cables on low voltage control signal cables is analyzed
引用
收藏
页码:273 / 276
页数:4
相关论文
共 50 条
  • [1] Near Field Coupling Measurement and Modeling between High Voltage and Low Voltage Cables in Electric Vehicles
    Yang, Le
    Wang, Shuo
    Zhi, Yongjian
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND SIGNAL & POWER INTEGRITY VIRTUAL SYMPOSIUM(IEEE EMC+SIPI), 2020, : 404 - 406
  • [2] ELECTRICAL AND ENVIRONMENTAL-PROTECTION OF HIGH-VOLTAGE AND LOW-VOLTAGE MINE CABLES
    MEI, RW
    MOORE, DJ
    STROMBOM, RA
    CIM BULLETIN, 1980, 73 (823): : 102 - 107
  • [3] THE DEVELOPMENT OF HIGH-VOLTAGE CABLES
    HASTIE, JS
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1953, 100 (122): : 79 - 79
  • [4] Analysis of the Low Frequency Shielding Behavior of High Voltage Cables in Electric Vehicles
    Feldhues, Katharina
    Diebig, Maja
    Frei, Stephan
    2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2014, : 408 - 413
  • [5] An evaluation of condition monitoring techniques for low-voltage electric cables
    2000, American Society of Mechanical Engineers (409):
  • [6] LOCALIZATION OF FAULTS IN LOW-VOLTAGE CABLES
    不详
    NATURE, 1945, 156 (3955) : 201 - 201
  • [7] HIGH-VOLTAGE CABLES WITH EXTERNAL COOLING
    BRAKELMANN, H
    ETZ ARCHIV, 1980, 2 (03): : 77 - 86
  • [8] Protection of high-voltage AC cables
    Tziouvaras, Demetrios A.
    2006 Power Systems Conference Advanced Metering, Protection, Control, Communication, and Distributed Resources, 2006, : 314 - 326
  • [9] On economic-technological optimization of high-voltage electric cables
    Meilunas, Mecislavas
    Ilgevicius, Audrius
    Suboc, Olga
    Jankeviciute, Gerda
    Ciegis, Raimondas
    NONLINEAR ANALYSIS-MODELLING AND CONTROL, 2017, 22 (01): : 134 - 146
  • [10] THEORY OF SHIELDED HIGH-VOLTAGE CABLES
    FRANK, RF
    PULP & PAPER-CANADA, 1989, 90 (06) : 123 - 125