Influence of contrast medium on tophus detection using dual-energy CT: phantom study and clinical illustration

被引:4
|
作者
Kotlyarov, Maximilian [1 ]
Mews, Jurgen [2 ]
Ulas, Sevtap Tugce [1 ]
Ziegeler, Katharina [1 ]
Hamm, Bernd [1 ]
Diekhoff, Torsten [1 ]
机构
[1] Charite Univ Med Berlin, Dept Radiol, Campus MitteCampus Mitte, D-10117 Berlin, Germany
[2] Europe BV, Canon Med Syst, Zoetermeer, Netherlands
关键词
Arthritis (gouty); Contrast media; Phantoms (imaging); Tomography (x-ray computed); Uric acid; COMPUTED-TOMOGRAPHY; GOUT; URATE;
D O I
10.1186/s41747-023-00348-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background To investigate the influence of iodinated contrast medium (ICM) on detection of monosodium urate (MSU) with dual-energy computed tomography (DECT) in two types of phantoms and demonstrate an example patient for clinical illustration. Methods Approval is by the institutional review board, and written informed consent was obtained. A grid-like and a biophantom with 25 suspensions containing different concentrations of ICM (0 to 2%) and MSU (0 to 50%) were prepared and scanned with sequential single-source DECT using established methodology. Ascending orders of tube currents were applied at 80 kVp (16.5 to 220.0 mAs) and 135 kVp (2.75 to 19.25 mAs). Volume and mass measurements were performed using clinical gout software (dual-energy decomposition analysis). Numbers of true-positive and false-positive MSU detections were recorded and compared for different ICM concentrations. We demonstrate a patient with gouty arthritis for clinical illustration. Results Effects of ICM on MSU detection varied with the amount of iodine. Lower ICM concentrations (0.25 and 0.50%) improved detection of small uric acid concentrations of 35 to 45% in comparison to scans without ICM. However, high ICM concentrations (1 and 2%) almost completely precluded MSU detection for all MSU concentrations investigated. In a patient with gouty arthritis, tophi in the wrist were only detected after intravenous ICM administration. Conclusions Exploring multimodal DECT for arthritis imaging, enhancement of ICM influences tophus detection. It can help in visualizing previously undetected MSU depositions but, with too strong enhancement, also obscure tophi. Relevance statement Use of iodinated contrast media in dual-energy CT might help in visualizing previously undetected uric acid depositions but, with too strong enhancement, obscure gouty tophi.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Accurate Multi-Material Decomposition in Dual-Energy CT: A Phantom Study
    Xue, Yi
    Jiang, Yangkang
    Yang, Chunlin
    Lyu, Qihui
    Wang, Jing
    Luo, Chen
    Zhang, Luhan
    Desrosiers, Catherine
    Feng, Kun
    Sun, Xiaonan
    Hu, Xiuhua
    Sheng, Ke
    Niu, Tianye
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2019, 5 (04) : 515 - 529
  • [32] Clinical Applications of Dual-Energy CT
    Hamid, Saira
    Nasir, Muhammad Umer
    So, Aaron
    Andrews, Gordon
    Nicolaou, Savvas
    Qamar, Sadia Raheez
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (06) : 970 - 982
  • [33] Dual-contrast decomposition of dual-energy CT using convolutional neural networks
    Shapira, Nadav
    Cao, Wenchao
    Liu, Leening P.
    Leiner, Tim
    Smits, Maarten L. J.
    Noel, Peter B.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [34] Accuracy of iodine removal using dual-energy CT with or without a tin filter: an experimental phantom study
    Kawai, Tatsuya
    Takeuchi, Mitsuru
    Hara, Masaki
    Ohashi, Kazuya
    Suzuki, Hirochika
    Yamada, Kiyotaka
    Sugimura, Yuya
    Shibamoto, Yuta
    ACTA RADIOLOGICA, 2013, 54 (08) : 954 - 960
  • [35] Contrast thresholds for detection of various iodine concentrations in subtraction CT and dual-energy CT systems
    Heshmat, Anahita
    Barreto, Izabella
    Rill, Lynn
    Liu, Sitong
    Patel, Romin
    Arreola, Manuel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (01):
  • [36] The accuracy of bone mineral density measurement using dual-energy spectral CT and quantitative CT: a comparative phantom study
    Li, X.
    Li, J.
    Jiao, X.
    Jia, X.
    Zhang, X.
    Fan, G.
    Yang, J.
    Guo, J.
    CLINICAL RADIOLOGY, 2020, 75 (04) : 320.e9 - 320.e15
  • [37] Harnessing dual-energy CT for glycogen quantification: a phantom analysis
    Li, Meiqin
    Li, Zhoulei
    Wei, Luyong
    Li, Lujie
    Wang, Meng
    He, Shaofu
    Peng, Zhenpeng
    Feng, Shi-Ting
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (08) : 4933 - 4942
  • [38] Influence of beam hardening in dual-energy CT imaging: phantom study for iodine mapping, virtual monoenergetic imaging, and virtual non-contrast imaging
    Kanatani, Risa
    Shirasaka, Takashi
    Kojima, Tsukasa
    Kato, Toyoyuki
    Kawakubo, Masateru
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
  • [39] Influence of beam hardening in dual-energy CT imaging: phantom study for iodine mapping, virtual monoenergetic imaging, and virtual non-contrast imaging
    Risa Kanatani
    Takashi Shirasaka
    Tsukasa Kojima
    Toyoyuki Kato
    Masateru Kawakubo
    European Radiology Experimental, 5
  • [40] Twin beam dual-energy vs single-energy on a novel PET-dual energy CT: Phantom study and clinical validation.
    De Cecco, Carlo
    Burchett, Philip
    De Santis, Domenico
    Ravenel, James
    Schoepf, U.
    Gordon, Leonie
    Jackson, Logan
    Rieter, William
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59