Influence of contrast medium on tophus detection using dual-energy CT: phantom study and clinical illustration

被引:4
|
作者
Kotlyarov, Maximilian [1 ]
Mews, Jurgen [2 ]
Ulas, Sevtap Tugce [1 ]
Ziegeler, Katharina [1 ]
Hamm, Bernd [1 ]
Diekhoff, Torsten [1 ]
机构
[1] Charite Univ Med Berlin, Dept Radiol, Campus MitteCampus Mitte, D-10117 Berlin, Germany
[2] Europe BV, Canon Med Syst, Zoetermeer, Netherlands
关键词
Arthritis (gouty); Contrast media; Phantoms (imaging); Tomography (x-ray computed); Uric acid; COMPUTED-TOMOGRAPHY; GOUT; URATE;
D O I
10.1186/s41747-023-00348-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background To investigate the influence of iodinated contrast medium (ICM) on detection of monosodium urate (MSU) with dual-energy computed tomography (DECT) in two types of phantoms and demonstrate an example patient for clinical illustration. Methods Approval is by the institutional review board, and written informed consent was obtained. A grid-like and a biophantom with 25 suspensions containing different concentrations of ICM (0 to 2%) and MSU (0 to 50%) were prepared and scanned with sequential single-source DECT using established methodology. Ascending orders of tube currents were applied at 80 kVp (16.5 to 220.0 mAs) and 135 kVp (2.75 to 19.25 mAs). Volume and mass measurements were performed using clinical gout software (dual-energy decomposition analysis). Numbers of true-positive and false-positive MSU detections were recorded and compared for different ICM concentrations. We demonstrate a patient with gouty arthritis for clinical illustration. Results Effects of ICM on MSU detection varied with the amount of iodine. Lower ICM concentrations (0.25 and 0.50%) improved detection of small uric acid concentrations of 35 to 45% in comparison to scans without ICM. However, high ICM concentrations (1 and 2%) almost completely precluded MSU detection for all MSU concentrations investigated. In a patient with gouty arthritis, tophi in the wrist were only detected after intravenous ICM administration. Conclusions Exploring multimodal DECT for arthritis imaging, enhancement of ICM influences tophus detection. It can help in visualizing previously undetected MSU depositions but, with too strong enhancement, also obscure tophi. Relevance statement Use of iodinated contrast media in dual-energy CT might help in visualizing previously undetected uric acid depositions but, with too strong enhancement, obscure gouty tophi.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Influence of contrast medium on tophus detection using dual-energy CT: phantom study and clinical illustration
    Maximilian Kotlyarov
    Jürgen Mews
    Sevtap Tugce Ulas
    Katharina Ziegeler
    Bernd Hamm
    Torsten Diekhoff
    European Radiology Experimental, 7
  • [2] Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study
    Jia Wang
    Mingliang Qu
    Xinhui Duan
    Naoki Takahashi
    Akira Kawashima
    Shuai Leng
    Cynthia H. McCollough
    European Radiology, 2012, 22 : 2589 - 2596
  • [3] Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study
    Wang, Jia
    Qu, Mingliang
    Duan, Xinhui
    Takahashi, Naoki
    Kawashima, Akira
    Leng, Shuai
    McCollough, Cynthia H.
    EUROPEAN RADIOLOGY, 2012, 22 (12) : 2589 - 2596
  • [4] Tophus resolution with pegloticase: a prospective dual-energy CT study
    Araujo, Elizabeth G.
    Bayat, Sara
    Petsch, Christina
    Englbrecht, Matthias
    Faustini, Francesca
    Kleyer, Arnd
    Hueber, Axel J.
    Cavallaro, Alexander
    Lell, Michael
    Dalbeth, Nicola
    Manger, Bernhard
    Schett, Georg
    Rech, Juergen
    RMD OPEN, 2015, 1 (01):
  • [5] Gout tophus detection - A comparison of dual-energy CT(DECT) and histology
    Melzer, R.
    Pauli, C.
    Treumann, T.
    Krauss, B.
    SWISS MEDICAL WEEKLY, 2016, 146 : 10S - 10S
  • [6] Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study
    Ren, Liqiang
    Rajendran, Kishore
    McCollough, Cynthia H.
    Yu, Lifeng
    MEDICAL PHYSICS, 2020, 47 (02) : 441 - 456
  • [7] Gout tophus detection-A comparison of dual-energy CT (DECT) and histology
    Melzer, Ralph
    Pauli, Chantal
    Treumann, Thomas
    Krauss, Bernhard
    SEMINARS IN ARTHRITIS AND RHEUMATISM, 2014, 43 (05) : 662 - 665
  • [8] Lower limit of iron quantification using dual-energy CT - a phantom study
    Jiang, Xia
    Hintenlang, David E.
    White, Richard D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (01): : 299 - 307
  • [9] Detection of Lumbar Spine Osseous Metastases Using Dual-Energy CT: Phantom Results and Preliminary Clinical Validation
    Huang, Hsu-Cheng
    Srinivasan, Ramya
    Sun, Yuxin
    Kazakia, Galateia J.
    Lin, Pei-Chen
    Yeh, Benjamin M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (02) : 402 - 410
  • [10] Bowel Peristalsis Artifact on Dual-Energy CT: In Vitro Study on the Influence of Different Dual-Energy CT Platforms and Enteric Contrast Agents
    Obmann, Markus M.
    Sun, Yuxin
    An, Chansik
    Ohliger, Michael A.
    Wang, Zhen J.
    Yeh, Benjamin M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (02) : 290 - 299