Thermal performance and thermal transmittance prediction of novel light-gauge steel-framed straw walls

被引:8
|
作者
Sun, Kuo [1 ]
Zheng, Chaorong [1 ,2 ]
Wang, Xiaodong [3 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
[2] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[3] Harbin Univ Sci & Technol, Sch Architectural & Civil Engn, Harbin 150080, Peoples R China
来源
基金
国家重点研发计划;
关键词
Light -gauge steel -framed wall; Broken bridge; Straw boards; Thermal performance; U m -value prediction; BRIDGES;
D O I
10.1016/j.jobe.2023.105973
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal bridges in light-gauge steel-framed exterior walls lead to more winter heat loss, summer heat gain, and building pathologies generated by moisture condensation and mould growth, which are unfavorable for building energy efficiency and service life of sheathing panels. A novel light-gauge steel-framed straw wall with a nonmetallic broken bridge layer was proposed, which consists of two sheathing panels on both sides of the wall, two frames, a middle sandwich layer, and two kinds of fasteners. The environmentally friendly straw boards including paper straw board (PSB) and wheat straw strand board (WSSB) were used as middle sandwich layer and exterior panel respectively. This study focuses on the thermal performance and the prediction method of thermal transmittance (Um-value) for such walls. Tests using the temperature control box-heat flux meter method were carried out for three representative walls with different configurations. Based on analyses of the temperature and heat flux density distributions, it is found that the broken bridge layer and the airspaces between the sheathing panel and the track or the bracing can effectively reduce the thermal bridge effect, with the relative effects less than 5%. Based on the test results of the Um-values, different wall configurations were matched with the feasible climate zones on the basis of energy efficiency design. After the validation by comparing with the test results in terms of temperature, heat flux density, and Um-value, the numerical study was carried out to broaden the feasible climate zones, and walls with improved configurations were proposed and analyzed. The results show that, by replacing the unventilated airspaces with the expanded polystyrene (EPS) boards, a maximum improvement in thermal performance reaches 74.89%. Thus, the feasible climate zones of the walls have been extended to the severe cold zone. Finally, a thermal transmittance prediction methodology based on the calculation method specified in European Standard EN ISO 6946-2017 in conjunction with the modified method considering thermal bridge effect was used to predict the Um-values of the improved walls. This study provides a new design strategy with nonmetallic broken bridge layer to reduce the unfavorable influence of thermal bridges in light-gauge steel-framed walls. Such a design strategy contributes to less energy consumption in addition to making full use of agricultural waste straw, which plays a positive role in the development of green buildings.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Lightweight steel-framed thermal bridges mitigation strategies: A parametric study
    Martins, Claudio
    Santos, Paulo
    da Silva, Luis Simoes
    JOURNAL OF BUILDING PHYSICS, 2016, 39 (04) : 342 - 372
  • [32] Shear resistance of gypsum-sheathed light-gauge steel stud walls
    Serrette, R
    Ogunfunmi, K
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (04): : 383 - 389
  • [33] Numerical Study of Thermal Efficiency in Light-Gauge Steel Panels Designed with Varying Insulation Ratios
    Chandrasiri, Dilanka
    Gatheeshgar, Perampalam
    Ahmadi, Hadi Monsef
    Simwanda, Lenganji
    BUILDINGS, 2024, 14 (01)
  • [34] Research on performance-based seismic design of light-gauge steel framed system for multi-storey residences
    Dong, J
    Zhang, XJ
    Xia, BT
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING: NEW FRONTIER AND RESEARCH TRANSFORMATION, 2004, : 550 - 555
  • [35] Comparing hysteretic behavior of light-gauge, steel plate shear walls and braced frames
    Berman, JW
    Celik, OC
    Bruneau, M
    ENGINEERING STRUCTURES, 2005, 27 (03) : 475 - 485
  • [36] Thermal Performance of Lightweight Steel Framed Facade Walls Using Thermal Break Strips and ETICS: A Parametric Study
    Santos, Paulo
    Lopes, Paulo
    Abrantes, David
    ENERGIES, 2023, 16 (04)
  • [37] The Importance of Stud Flanges Size and Shape on the Thermal Performance of Lightweight Steel Framed Walls
    Santos, Paulo
    Poologanathan, Keerthan
    SUSTAINABILITY, 2021, 13 (07)
  • [38] Seismic Fragility of Chinese Light-Gauge Steel Keel Gypsum Board Partition Walls
    Wang, Duozhi
    Zhi, Xudong
    Zhu, Fangxu
    Wang, Yixing
    SHOCK AND VIBRATION, 2021, 2021 (2021)
  • [39] Behaviour of light-gauge steel-frame - wood structural panel shear walls
    Chen, C. Y.
    Boudreault, F. A.
    Branston, A. E.
    Rogers, C. A.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2006, 33 (05) : 573 - 587
  • [40] Testing of light-gauge steel-frame - wood structural panel shear walls
    Branston, A. E.
    Chen, C. Y.
    Boudreault, F. A.
    Rogers, C. A.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2006, 33 (05) : 561 - 572