T1 mapping of rat lungs in 19F MRI using octafluorocyclobutane

被引:1
|
作者
Pavlova, Olga S. [1 ,2 ]
Gulyaev, Mikhail V. [1 ]
Gervits, Lev L. [3 ]
Hurshkainen, Anna A. [4 ]
Nikulin, Anton V. [5 ]
Puchnin, Viktor M. [4 ]
Teploukhova, Ekaterina D. [2 ]
Kuropatkina, Tatyana A. [1 ]
Anisimov, Nikolay V. [1 ]
Medvedeva, Nataliya A. [6 ]
Pirogov, Yury A. [2 ]
机构
[1] Lomonosov Moscow State Univ, Fac Med, Moscow, Russia
[2] Lomonosov Moscow State Univ, Fac Phys, Moscow, Russia
[3] Russian Acad Sci, Nesmeyanov Inst Organoelement Cpds, Moscow, Russia
[4] ITMO Univ, Sch Phys & Engn, St Petersburg, Russia
[5] Moscow Inst Phys & Technol, Ctr Photon & 2D Mat, Dolgoprudnyi, Russia
[6] Lomonosov Moscow State Univ, Fac Biol, Moscow, Russia
基金
俄罗斯科学基金会;
关键词
F-19; MRI; lung imaging; octafluorocyclobutane; T(1 )mapping; T-2(& lowast; ) mapping; UTE; ULTRASHORT ECHO TIME; SPIN-LATTICE RELAXATION; PULMONARY-HYPERTENSION; QUANTITATIVE T-1; DIFFUSION; ANGLE; VENTILATION; DENSITY; MODEL; SEQUENCES;
D O I
10.1002/mrm.29606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate the feasibility of using octafluorocyclobutane (OFCB, c-C4F8) for T-1 mapping of lungs in F-19 MRI.Methods: The study was performed at 7 T in three healthy rats and three rats with pulmonary hypertension. To increase the sensitivity of F-19 MRI, a bent-shaped RF coil with periodic metal strips structure was used. The double flip angle method was used to calculate normalized transmitting RF field (B-1n(+)) maps and for correcting T-1 maps built with the variable flip angle (VFA) method. The ultrashort TE pulse sequence was applied for acquiring MR images throughout the study.Results: The dependencies of OFCB relaxation times on its partial pressure in mixtures with oxygen, air, helium, and argon were obtained. T-1 of OFCB linearly depended on its partial pressure with the slope of about 0.35 ms/kPa in the case of free diffusion. RF field inhomogeneity leads to distortion of T-1 maps built with the VFA method, and therefore to high standard deviation of T-1 in these maps. To improve the accuracy of the T-1 maps, the B-1n(+) maps were applied for VFA correction. This contributed to a 2-3-fold decrease in the SD of T-1 values in the corresponding maps compared with T-1 maps calculated without the correction. Three-dimensional T-1 maps were obtained, and the mean T-1 in healthy rat lungs was 35 & PLUSMN; 10 ms, and in rat lungs with pulmonary hypertension - 41 & PLUSMN; 9 ms.Conclusion: OFCB has a spin-rotational relaxation mechanism and can be used for F-19 T-1 mapping of lungs. The calculated OFCB maps captured ventilation defects induced by edema.
引用
收藏
页码:2318 / 2331
页数:14
相关论文
共 50 条
  • [21] Realization of 19F MRI oximetry method using perfluorodecalin
    Mikhail V. Gulyaev
    Aleksandra V. Kuznetsova
    Denis N. Silachev
    Tatyana I. Danilina
    Lev L. Gervits
    Yury A. Pirogov
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 307 - 315
  • [22] 19F MRI: Dream or reality
    Pierre, Valerie
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [23] Quantitative Tissue Oxygen Measurement in Multiple Organs Using 19F MRI in a Rat Model
    Liu, Siyuan
    Shah, Sameer J.
    Wilmes, Lisa J.
    Feiner, John
    Kodibagkar, Vikram D.
    Wendland, Michael F.
    Mason, Ralph P.
    Hylton, Nola
    Hopf, Harriet W.
    Rollins, Mark D.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (06) : 1722 - 1730
  • [24] Labeling cells for in vivo tracking using 19F MRI
    Srinivas, Mangala
    Boehm-Sturm, Philipp
    Figdor, Carl G.
    de Vries, I. Jolanda
    Hoehn, Mathias
    BIOMATERIALS, 2012, 33 (34) : 8830 - 8840
  • [25] Using 19F MRI for In Vivo Tracking of Therapeutic Cells
    Mailliard, Robie B.
    Helfer, Brooke M.
    Janjic, Jelena M.
    Kalinski, Pawel
    Ahrens, Eric T.
    JOURNAL OF IMMUNOTHERAPY, 2009, 32 (09) : 948 - 948
  • [26] Assessment of myocardial fibrosis with T1 mapping MRI
    Everett, R. J.
    Stirrat, C. G.
    Semple, S. I. R.
    Newby, D. E.
    Dweck, M. R.
    Mirsadraee, S.
    CLINICAL RADIOLOGY, 2016, 71 (08) : 768 - 778
  • [27] MRI T1 Mapping of the Right Ventricle Using High Resolution ANGIE
    Mehta, Bhairav B.
    Chen, Xiao
    Salerno, Michael
    Kramer, Christopher M.
    Bilchick, Kenneth C.
    Epstein, Frederick H.
    CIRCULATION, 2013, 128 (22)
  • [28] Quantitative T1 mapping and absolute water content measurement using MRI
    Neeb, H
    Dierkes, T
    Shah, NJ
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 113 - 123
  • [29] Longitudinal stability of gel T1 MRI Phantoms for quality assurance of T1 mapping
    Vassilis Vassiliou
    Ee Ling Heng
    Jackie Donovan
    Andreas Greiser
    Sonya V Babu-Narayan
    Michael A Gatzoulis
    David Firmin
    Dudley J Pennell
    Peter Gatehouse
    Sanjay K Prasad
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [30] Diagnosis of Acute Cholecystitis Using T1 and T2 Mapping by Cardiac MRI
    Sen, Gautam
    Knott, Kristopher
    Rosmini, Stefania
    CIRCULATION-CARDIOVASCULAR IMAGING, 2023, 16 (10) : E015605