Diagnostic performance of 3D cardiac magnetic resonance perfusion in elderly patients for the detection of coronary artery disease as compared to fractional flow reserve

被引:3
作者
Karolyi, Mihaly [1 ]
Gotschy, Alexander [1 ,2 ,3 ,4 ]
Polacin, Malgorzata [1 ,3 ,4 ]
Plein, Sven [5 ,6 ]
Paetsch, Ingo [7 ]
Jahnke, Cosima [7 ]
Frick, Michael [8 ]
Gebker, Rolf [9 ]
Alkadhi, Hatem [1 ]
Kozerke, Sebastian [3 ,4 ]
Manka, Robert [1 ,2 ,3 ,4 ]
机构
[1] Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Hosp Zurich, Univ Heart Ctr, Dept Cardiol, Zurich, Switzerland
[3] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Zurich, Switzerland
[5] Univ Leeds, Multidisciplinary Cardiovasc Res Ctr, Leeds Inst Cardiovasc & Metab Med, Leeds, W Yorkshire, England
[6] Univ Leeds, Dept Biomed Imaging Sci, Leeds Inst Cardiovasc & Metab Med, Leeds, W Yorkshire, England
[7] Univ Leipzig, Dept Electrophysiol, HELIOS Heart Ctr Leipzig, Leipzig, Germany
[8] Univ Hosp RWTH Aachen, Dept Cardiol Pneumol Angiol & Intens Care Med, Aachen, Germany
[9] German Heart Inst, Berlin, Germany
关键词
Aged; Coronary angiography; Coronary artery disease; Fractional flow reserve; Myocardial perfusion imaging; EMISSION COMPUTED-TOMOGRAPHY; MR-IMPACT; CE-MARC; HEART; MULTICENTER; GUIDELINES; MULTIVENDOR; MANAGEMENT;
D O I
10.1007/s00330-022-09040-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives In patients of advanced age, the feasibility of myocardial ischemia testing might be limited by age-related comorbidities and falling compliance abilities. Therefore, we aimed to test the accuracy of 3D cardiac magnetic resonance (CMR) stress perfusion in the elderly population as compared to reference standard fractional flow reserve (FFR). Methods Fifty-six patients at age 75 years or older (mean age 79 +/- 4 years, 35 male) underwent 3D CMR perfusion imaging and invasive coronary angiography with FFR in 5 centers using the same study protocol. The diagnostic accuracy of CMR was compared to a control group of 360 patients aged below 75 years (mean age 61 +/- 9 years, 262 male). The percentage of myocardial ischemic burden (MIB) relative to myocardial scar burden was further analyzed using semi-automated software. Results Sensitivity, specificity, and positive and negative predictive values of 3D perfusion CMR deemed similar for both age groups in the detection of hemodynamically relevant (FFR < 0.8) stenosis (>= 75 years: 86%, 83%, 92%, and 75%; < 75 years: 87%, 80%, 82%, and 85%; p > 0.05 all). While MIB was larger in the elderly patients (15% +/- 17% vs. 9% +/- 13%), the diagnostic accuracy of 3D CMR perfusion was high in both elderly and non-elderly populations to predict pathological FFR (AUC: 0.906 and 0.866). Conclusions 3D CMR perfusion has excellent diagnostic accuracy for the detection of hemodynamically relevant coronary stenosis, independent of patient age.
引用
收藏
页码:339 / 347
页数:9
相关论文
共 50 条
[41]   The diagnostic performance of quantitative flow ratio and perfusion imaging in patients with prior coronary artery disease [J].
van Diemen, Pepijn A. ;
de Winter, Ruben W. ;
Schumacher, Stefan P. ;
Everaars, Henk ;
Bom, Michiel J. ;
Jukema, Ruurt A. ;
Somsen, Yvemarie B. ;
Raijmakers, Pieter G. ;
Kooistra, Rolf A. ;
Timmer, Janny ;
Maaniitty, Teemu ;
Robbers, Lourens F. ;
von Bartheld, Martin B. ;
Demirkiran, Ahmet ;
van Rossum, Albert C. ;
Reiber, Johan H. ;
Knuuti, Juhani ;
Underwood, Richard S. ;
Nagel, Eike ;
Knaapen, Paul ;
Driessen, Roel S. ;
Danad, Ibrahim .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2023, 25 (01) :116-126
[42]   Additive Value of Magnetic Resonance Coronary Angiography in a Comprehensive Cardiac Magnetic Resonance Stress-Rest Protocol for Detection of Functionally Significant Coronary Artery Disease A Pilot Study [J].
Bettencourt, Nuno ;
Ferreira, Nuno ;
Chiribiri, Amedeo ;
Schuster, Andreas ;
Sampaio, Francisco ;
Santos, Lino ;
Melica, Bruno ;
Rodrigues, Alberto ;
Braga, Pedro ;
Teixeira, Madalena ;
Leite-Moreira, Adelino ;
Silva-Cardoso, Jose ;
Portugal, Pedro ;
Gama, Vasco ;
Nagel, Eike .
CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (05) :730-738
[43]   Significance of Intermediate Values of Fractional Flow Reserve in Patients With Coronary Artery Disease [J].
Adjedj, Julien ;
De Bruyne, Bernard ;
Flore, Vincent ;
Di Gioia, Giuseppe ;
Ferrara, Angela ;
Pellicano, Mariano ;
Toth, Gabor G. ;
Bartunek, Jozef ;
Vanderheyden, Marc ;
Heyndrickx, Guy R. ;
Wijns, William ;
Barbato, Emanuele .
CIRCULATION, 2016, 133 (05) :502-508
[44]   Diagnostic accuracy of combined dipyridamole stress perfusion and delayed enhancement cardiovascular magnetic resonance imaging for detection of coronary artery disease [J].
Chattranukulchai, Pairoj ;
Tumkosit, Monravee ;
Cholteesupachai, Jiranut ;
Chaipromprasit, Jarkarpun .
ASIAN BIOMEDICINE, 2010, 4 (01) :19-25
[45]   Diagnostic performance of cardiac imaging methods to diagnose ischaemia-causing coronary artery disease when directly compared with fractional flow reserve as a reference standard: a meta-analysis [J].
Danad, Ibrahim ;
Szymonifka, Jackie ;
Twisk, Josw. R. ;
Norgaard, Bjarne L. ;
Zarins, Christopher K. ;
Knaapen, Paul ;
Min, James K. .
EUROPEAN HEART JOURNAL, 2017, 38 (13) :991-+
[46]   Diagnostic performance of static single-scan stress perfusion cardiac computed tomography in detecting hemodynamically significant coronary artery stenosis: a comparison with combined invasive coronary angiography and cardiovascular magnetic resonance-myocardial perfusion imaging [J].
Song, Inyoung ;
Yi, Jeong Geun ;
Park, Jeong Hee ;
Kim, Mi Young ;
Shin, Je Kyoun ;
Ko, Sung Min .
ACTA RADIOLOGICA, 2018, 59 (10) :1184-1193
[47]   Vasodilator Myocardial Perfusion Cardiac Magnetic Resonance Imaging Is Superior to Dobutamine Stress Echocardiography in the Detection of Relevant Coronary Artery Stenosis: A Systematic Review and Meta-Analysis on Their Diagnostic Accuracy [J].
Haberkorn, Sebastian M. ;
Haberkorn, Sandra I. ;
Bonner, Florian ;
Kelm, Malte ;
Hopkin, Gareth ;
Petersen, Steffen E. .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
[48]   High spatial resolution myocardial perfusion cardiac magnetic resonance for the detection of coronary artery disease [J].
Plein, Sven ;
Kozerke, Sebastian ;
Suerder, Daniel ;
Luescher, Thomas F. ;
Greenwood, John P. ;
Boesiger, Peter ;
Schwitter, Juerg .
EUROPEAN HEART JOURNAL, 2008, 29 (17) :2148-2155
[49]   Incremental value of adenosine stress cardiac magnetic resonance in coronary artery disease detection [J].
Pereira, Eulalia ;
Bettencourt, Nuno ;
Ferreira, Nuno ;
Schuster, Andreas ;
Chiribiri, Amedeo ;
Primo, Joao ;
Teixeira, Madalena ;
Simoes, Lino ;
Leite-Moreira, Adelino ;
Silva-Cardoso, Jose ;
Gama, Vasco ;
Nagel, Eike .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) :4160-4167
[50]   Comparison of machine learning-based CT fractional flow reserve with cardiac MR perfusion mapping for ischemia diagnosis in stable coronary artery disease [J].
Guo, Weifeng ;
Zhao, Shihai ;
Xu, Haijia ;
He, Wei ;
Yin, Lekang ;
Yao, Zhifeng ;
Xu, Zhihan ;
Jin, Hang ;
Wu, Dong ;
Li, Chenguang ;
Yang, Shan ;
Zeng, Mengsu .
EUROPEAN RADIOLOGY, 2024, 34 (9) :5654-5665