Endovascular Aneurysm Repair With AFX Stent-Grafts or Tube Grafts for Sacciform Infrarenal Pathologies in a Narrow Aortic Anatomy

被引:4
|
作者
Lescan, Mario [1 ]
Andic, Mateja [1 ]
Serban, Denisa [1 ]
Artzner, Christoph [2 ]
Grozinger, Gerd [2 ]
Schlensak, Christian [1 ]
Estler, Arne [2 ]
Mustafi, Migdat [1 ]
机构
[1] Univ Med Ctr Tubingen, Dept Thorac & Cardiovasc Surg, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Univ Med Ctr Tubingen, Dept Radiol, Tubingen, Germany
关键词
endovascular aneurysm repair; abdominal aortic aneurysm; penetrating aortic ulcer; infrarenal; aneurysm neck; bifurcated stent-graft; DISTAL AORTA; ANGIOPLASTY; ENDOGRAFT; ULCERS; EVAR;
D O I
10.1177/15266028221079756
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The objective of this study was to compare the outcomes of patients treated with tube grafts and AFX stent-graft in the narrow infrarenal aortic anatomy. Materials and Methods: Patients with penetrating aortic ulcers (PAUs) or sacciform aneurysms of the infrarenal aorta and an aortic bifurcation diameter <= 20 mm who underwent endovascular aneurysm repair (EVAR) with bifurcated AFX or tube stent-grafts (TUBE) between 2012 and 2020 were included. Demographic data and the outcome of the AFX group were compared with the TUBE group. All morphological measurements in the preoperative and postoperative computed tomography scans were performed in the aortic centerline. Results: Fifty-one patients (female: 12/51; 29%; median age: 72 years [63, 77]) with a median follow-up of 10 (3, 39) months, were included, of whom 35/51 (69%) had PAUs and 11/51 were symptomatic (22%). The aortic bifurcation diameter was 17 mm (15, 18) with severe calcifications in 25/51 (49%). The distal aortic landing zone was longer in the TUBE group (9 mm vs 24 mm; p<0.001). The technical success was 96% with a median aneurysm shrinkage of 8% (3, 13), which was comparable between the groups (p=0.264). Periprocedural mortality, conversion to open surgery, myocardial infarction, and stroke were not observed. Two type Ia endoleaks (EL) and 2 type Ib EL occurred, all in the TUBE group (Type 1 EL; 19 vs 0%; p=0.013). The limb patency in the AFX group was 100%. One patient with a tube graft developed an infrarenal aortic thrombosis 40 months after the intervention. The reintervention rate in the TUBE group was higher (14 vs 0%; p=0.032) and included 3 aortic cuff implantations and 1 covered endovascular aortic reconstruction of aortic bifurcation (CERAB). Conclusion: AFX stent-graft showed a lower rate of type I endoleaks and reinterventions in sacciform infrarenal aortic pathologies during the early and midterm follow-up.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 50 条
  • [1] Supra or infrarenal aortic stent-grafts for endovascular aneurysm repair: study of renal function
    Gouny, Pierre
    Salley, Nicolas
    Clave, Arnaud
    Gueret, Gildas
    Badra, Ali
    Nonent, Michel
    E-MEMOIRES DE L ACADEMIE NATIONALE DE CHIRURGIE, 2010, 9 (01): : 89 - 95
  • [2] Fenestrated Stent-Grafts for Salvage of Prior Endovascular Abdominal Aortic Aneurysm Repair
    Katsargyris, A.
    Yazar, O.
    Oikonomou, K.
    Bekkema, F.
    Tielliu, I.
    Verhoeven, E. L. G.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (01) : 49 - 56
  • [3] Double tube stent-grafts for infrarenal aortic aneurysm:: A new concept
    Ruppert, Volker
    Erz, Kerstin
    Buerklein, Dominik
    Treiti, Marcus
    Steckmeiier, Bernd
    Stelter, Wolf
    Umscheid, Thomas
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (02) : 144 - 149
  • [4] Long-term renal function following endovascular aneurysm repair with infrarenal and suprarenal aortic stent-grafts
    Alric, P
    Hinchliffe, RJ
    Picot, MC
    Braithwaite, BD
    MacSweeney, STR
    Wenham, PW
    Hopkinson, BR
    JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (03) : 397 - 405
  • [5] Conversion of failed endovascular infrarenal aortic aneurysm repair with fenestrated/branched stent grafts
    Jessula, Samuel
    Eagleton, Matthew J.
    SEMINARS IN VASCULAR SURGERY, 2022, 35 (03) : 341 - 349
  • [6] Comparison of the fixation strength of standard and fenestrated Stent-Grafts for endovascular abdominal aortic aneurysm repair
    Zhou, Samuel S. N.
    How, Thien V.
    Vallabhaneni, S. Rao
    Gilling-Smith, Geoffrey L.
    Brennan, John A.
    Harris, Peter L.
    McWilliams, Richard
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (02) : 168 - 175
  • [7] Explant of aortic stent grafts following endovascular aneurysm repair
    Boyle, E.
    McHugh, S. M.
    Elmallah, A.
    Lynch, M.
    McGuire, D.
    Ahmed, Z.
    Canning, C.
    Colgan, M. P.
    O'Neill, S. M.
    O'Callaghan, A.
    Martin, Z.
    Madhavan, P.
    VASCULAR, 2019, 27 (05) : 487 - 494
  • [8] A critical appraisal of endovascular stent-grafts in the management of abdominal aortic aneurysms
    Schoretsanitis, Nikolaos
    Georgakarakos, Efstratios
    Argyriou, Christos
    Ktenidis, Kiriakos
    Georgiadis, George S.
    RADIOLOGIA MEDICA, 2017, 122 (04): : 309 - 318
  • [9] Endovascular Aneurysm Sealing of a Collapsed and Thrombosed Aortic Stent-Graft With Renovisceral Chimney Stent-Grafts
    Lareyre, Fabien
    Mialhe, Claude
    Dommerc, Carine
    Raffort, Juliette
    JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (01) : 72 - 75
  • [10] Transfemoral repair of infrarenal abdominal aortic aneurysms with use of stent-grafts - First experiences
    Spillner, G
    Blum, U
    Langer, M
    Schlosser, V
    Beyersdorf, F
    ZENTRALBLATT FUR CHIRURGIE, 1996, 121 (09): : 727 - 733