Comparison of methods for intravoxel incoherent motion parameter estimation in the brain from flow-compensated and non-flow-compensated diffusion-encoded data

被引:2
作者
Jalnefjord, Oscar [1 ,2 ,5 ]
Bjorkman-Burtscher, Isabella M. [3 ,4 ]
机构
[1] Univ Gothenburg, Inst Clin Sci, Sahlgrenska Acad, Dept Med Radiat Sci, Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Reg Vastra Gotaland, Gothenburg, Sweden
[3] Univ Gothenburg, Inst Clin Sci, Sahlgrenska Acad, Dept Radiol, Gothenburg, Sweden
[4] Sahlgrens Univ Hosp, Dept Radiol, Sect Neuroradiol, Reg Vastra Gotaland, Gothenburg, Sweden
[5] MRI Ctr, Bruna Straket 13, S-41345 Gothenburg, Sweden
关键词
diffusion; IVIM; model fitting; MRI; perfusion; WEIGHTED MRI; PERFUSION; OPTIMIZATION; IMPACT; IMAGES; MODEL; MAPS; TIME;
D O I
10.1002/mrm.30042
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeJoint analysis of flow-compensated (FC) and non-flow-compensated (NC) diffusion MRI (dMRI) data has been suggested for increased robustness of intravoxel incoherent motion (IVIM) parameter estimation. For this purpose, a set of methods commonly used or previously found useful for IVIM analysis of dMRI data obtained with conventional diffusion encoding were evaluated in healthy human brain. MethodsFive methods for joint IVIM analysis of FC and NC dMRI data were compared: (1) direct non-linear least squares fitting, (2) a segmented fitting algorithm with estimation of the diffusion coefficient from higher b-values of NC data, (3) a Bayesian algorithm with uniform prior distributions, (4) a Bayesian algorithm with spatial prior distributions, and (5) a deep learning-based algorithm. Methods were evaluated on brain dMRI data from healthy subjects and simulated data at multiple noise levels. Bipolar diffusion encoding gradients were used with b-values 0-200 s/mm2 and corresponding flow weighting factors 0-2.35 s/mm for NC data and by design 0 for FC data. Data were acquired twice for repeatability analysis. ResultsMeasurement repeatability as well as estimation bias and variability were at similar levels or better with the Bayesian algorithm with spatial prior distributions and the deep learning-based algorithm for IVIM parameters D$$ D $$ and f$$ f $$, and for the Bayesian algorithm only for vd$$ {v}_d $$, relative to the other methods. ConclusionA Bayesian algorithm with spatial prior distributions is preferable for joint IVIM analysis of FC and NC dMRI data in the healthy human brain, but deep learning-based algorithms appear promising.
引用
收藏
页码:303 / 318
页数:16
相关论文
共 52 条
  • [1] Quantification of microcirculatory parameters by joint analysis of flow-compensated and non-flow-compensated intravoxel incoherent motion (IVIM) data
    Ahlgren, Andre
    Knutsson, Linda
    Wirestam, Ronnie
    Nilsson, Markus
    Stahlberg, Freddy
    Topgaard, Daniel
    Lasic, Samo
    [J]. NMR IN BIOMEDICINE, 2016, 29 (05) : 640 - 649
  • [2] Convex optimized diffusion encoding (CODE) gradient waveforms for minimum echo time and bulk motion-compensated diffusion-weighted MRI
    Aliotta, Eric
    Wu, Holden H.
    Ennis, Daniel B.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 717 - 729
  • [3] How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
    Andersson, JLR
    Skare, S
    Ashburner, J
    [J]. NEUROIMAGE, 2003, 20 (02) : 870 - 888
  • [4] Deep learning how to fit an intravoxel incoherent motion model to diffusion-weighted MRI
    Barbieri, Sebastiano
    Gurney-Champion, Oliver J.
    Klaassen, Remy
    Thoeny, Harriet C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (01) : 312 - 321
  • [5] Impact of the calculation algorithm on biexponential fitting of diffusion-weighted MRI in upper abdominal organs
    Barbieri, Sebastiano
    Donati, Olivio F.
    Froehlich, Johannes M.
    Thoeny, Harriet C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (05) : 2175 - 2184
  • [6] Charlier F., 2022, PERMUTATIONS STATS V
  • [7] Comparison of Fitting Methods and b-Value Sampling Strategies for Intravoxel Incoherent Motion in Breast Cancer
    Cho, Gene Young
    Moy, Linda
    Zhang, Jeff L.
    Baete, Steven
    Lattanzi, Riccardo
    Moccaldi, Melanie
    Babb, James S.
    Kim, Sungheon
    Sodickson, Daniel K.
    Sigmund, Eric E.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 1077 - 1085
  • [9] Reliable estimation of incoherent motion parametric maps from diffusion-weighted MRI using fusion bootstrap moves
    Freiman, Moti
    Perez-Rossello, Jeannette M.
    Callahan, Michael J.
    Voss, Stephan D.
    Ecklund, Kirsten
    Mulkern, Robert V.
    Warfield, Simon K.
    [J]. MEDICAL IMAGE ANALYSIS, 2013, 17 (03) : 325 - 336
  • [10] Geades N, 2021, P ANN M ISMRM, P1321