Verifying the Accuracy of Hemodynamic Analysis Using High Spatial Resolution 3D Phase-contrast MR Imaging on a 7T MR System: Comparison with a 3T System

被引:0
作者
Tajima, Shunsuke [1 ,2 ]
Isoda, Haruo [3 ,4 ]
Fukunaga, Masaki [5 ]
Komori, Yoshiaki [6 ]
Naganawa, Shinji [7 ]
Sadato, Norihiro [5 ,8 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Radiol & Med Lab Sci, Radiol Sci, Nagoya, Aichi, Japan
[2] Nagoya Univ Hosp, Dept Radiol Technol, Nagoya, Aichi, Japan
[3] Nagoya Univ, Brain & Mind Res Ctr, Nagoya, Aichi, Japan
[4] Nagoya Univ, Grad Sch Med, Dept Integrated Hlth Sci, 1-1-20 Daiko Minami,Higashi Ku, Nagoya, Aichi 4618673, Japan
[5] Natl Inst Physiol Sci, Div Cerebral Integrat, Okazaki, Aichi, Japan
[6] Siemens Healthcare KK, Tokyo, Japan
[7] Nagoya Univ, Grad Sch Med, Dept Radiol, Nagoya, Aichi, Japan
[8] Ritsumeikan Univ, Res Org Sci & Technol, Kyoto, Kyoto, Japan
关键词
hemodynamics; intracranial artery; phase-contrast MR imaging; 4D flow MRI; magnetic field strength; UNRUPTURED INTRACRANIAL ANEURYSMS; SUBARACHNOID HEMORRHAGE; SHEAR-STRESS; FLOW; VELOCITY; RUPTURE; RISK; QUANTIFICATION; QUALITY; PATIENT;
D O I
10.2463/mrms.mp.2023-0016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Hemodynamics is important in the initiation, growth, and rupture of intracranial aneurysms. Since intracranial aneurysms are small, a high -field MR system with high spatial resolution and high SNR is desirable for this hemodynamic analysis. The purpose of this study was to investigate whether the accuracy of MR fluid dynamic (MRFD) results based on 3D phase -contrast MR (3D PC MR, non-electrocardiogram[ECG]-gated 4D Flow MRI) data from a human cerebrovascular phantom and human healthy subjects obtained by a 7T MR system was superior to those by a 3T MR system. Methods: 3D PC MR and 3D time of flight MR angiography (3D TOF MRA) imaging were performed on a 3T MR system and a 7T MR system for a human cerebrovascular phantom and 10 healthy human subjects, and MRFD analysis was performed using these data. The MRFD results from each MR system were then compared with the following items based on the computational fluid dynamics (CFD) results: 3D velocity vector field; correlation coefficient (R), angular similarity index (ASI), and magnitude similarity index (MSI) of blood flow velocity vectors. Results: In the MRFD results of 3D velocity vectors of the cerebrovascular phantom, noise -like vectors were observed near the vascular wall on the 3T MR system, but no noise was observed on the 7T MR system, showing results similar to those of CFD. In the MRFD results of the cerebrovascular phantom and healthy subjects, the correlation coefficients R, ASI, and MSI of the 7T MR system were higher than those of the 3T MR system, and ASI and MSI of healthy human subjects were significantly different between the two systems. Conclusions: The accuracy of high spatial resolution MRFD using the 7T MR system exceeded that of the 3T MR system.
引用
收藏
页码:88 / 102
页数:15
相关论文
共 29 条
  • [21] Human hand imaging using a 20 cm high-temperature superconducting coil in a 3T magnetic resonance imaging system
    Lin, In-Tsang
    Yang, Hong-Chang
    Hsieh, Chang-Wei
    Jao, Tun
    Chen, Jyh-Horng
    JOURNAL OF APPLIED PHYSICS, 2010, 107 (12)
  • [22] Comparison between contrast-enhanced fat-suppressed 3D FLAIR brain MR images and T2-weighted orbital MR images at 3 Tesla for the diagnosis of acute optic neuritis
    Manasse, Sharmiladevi
    Koskas, Patricia
    Savatovsky, Julien
    Deschamps, Romain
    Vignal-Clermont, Catherine
    de la Motte, Marine Boudot
    Papeix, Caroline
    Trunet, Stephanie
    Lecler, Augustin
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (12) : 481 - 488
  • [23] Uterine Tumors: Comparison of 3D versus 2D T2-weighted Turbo Spin-Echo MR Imaging at 3.0 T-Initial Experience
    Hori, Masatoshi
    Kim, Tonsok
    Onishi, Hiromitsu
    Ueguchi, Takashi
    Tatsumi, Mitsuaki
    Nakamoto, Atsushi
    Tsuboyama, Takahiro
    Tomoda, Kaname
    Tomiyama, Noriyuki
    RADIOLOGY, 2011, 258 (01) : 154 - 163
  • [24] High-resolution intracranial vessel wall imaging using 3D CUBE T1 weighted sequence
    Li, Min-Li
    Xu, Yu-Yuan
    Hou, Bo
    Sun, Zhao-Yong
    Zhou, Hai-Long
    Jin, Zheng-Yu
    Feng, Feng
    Xu, Wei-Hai
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (04) : 803 - 807
  • [25] High-Resolution 3-T Endorectal Prostate MRI: A Multireader Study of Radiologist Preference and Perceived Interpretive Quality of 2D and 3D T2-Weighted Fast Spin-Echo MR Images
    Westphalen, Antonio C.
    Noworolski, Susan M.
    Harisinghani, Mukesh
    Jhaveri, Kartik S.
    Raman, Steve S.
    Rosenkrantz, Andrew B.
    Wang, Zhen J.
    Zagoria, Ronald J.
    Kurhanewicz, John
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (01) : 86 - 91
  • [26] Prostate Cancer: The European Society of Urogenital Radiology Prostate Imaging Reporting and Data System Criteria for Predicting Extraprostatic Extension by Using 3-T Multiparametric MR Imaging
    Bittencourt, Leonardo Kayat
    Litjens, Geert
    Hulsbergen-van de Kaa, Christina A.
    Turkbey, Baris
    Gasparetto, Emerson Leandro
    Barentsz, Jelle O.
    RADIOLOGY, 2015, 276 (02) : 479 - 489
  • [27] Follow-up imaging of clipped intracranial aneurysms with 3-T MRI: comparison between 3D time-of-flight MR angiography and pointwise encoding time reduction with radial acquisition subtraction-based MR angiography
    Kim, Jae Ho
    Ahn, Sung Jun
    Park, Mina
    Kim, Yong Bae
    Joo, Bio
    Lee, Woosung
    Suh, Sang Hyun
    JOURNAL OF NEUROSURGERY, 2022, 136 (05) : 1260 - 1265
  • [28] Advances of 3T MR Imaging in Visualizing Trabecular Bone Structure of the Calcaneus Are Partially SNR-Independent: Analysis Using Simulated Noise in Relation to Micro-CT, 1.5T MRI, and Biomechanical Strength
    Bauer, Jan S.
    Monetti, Roberto
    Krug, Roland
    Matsuura, Maiko
    Mueller, Dirk
    Eckstein, Felix
    Rummeny, Ernst J.
    Lochmueller, Eva-Maria
    Raeth, Christoph W.
    Link, Thomas M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (01) : 132 - 140
  • [29] Single-shot morpho-functional and structural characterization of the left-ventricle in a mouse model of acute ischemia-reperfusion injury with an optimized 3D IntraGate cine FLASH sequence at 7T MR
    Palmisano, Anna
    Piccoli, Marco
    Monti, Caterina Beatrice
    Canu, Tamara
    Cirillo, Federica
    Napolitano, Angela
    Perani, Laura
    Signorelli, Paola
    Vignale, Davide
    Anastasia, Luigi
    Esposito, Antonio
    MAGNETIC RESONANCE IMAGING, 2020, 68 : 127 - 135