Verifying the Accuracy of Hemodynamic Analysis Using High Spatial Resolution 3D Phase-contrast MR Imaging on a 7T MR System: Comparison with a 3T System

被引:0
作者
Tajima, Shunsuke [1 ,2 ]
Isoda, Haruo [3 ,4 ]
Fukunaga, Masaki [5 ]
Komori, Yoshiaki [6 ]
Naganawa, Shinji [7 ]
Sadato, Norihiro [5 ,8 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Radiol & Med Lab Sci, Radiol Sci, Nagoya, Aichi, Japan
[2] Nagoya Univ Hosp, Dept Radiol Technol, Nagoya, Aichi, Japan
[3] Nagoya Univ, Brain & Mind Res Ctr, Nagoya, Aichi, Japan
[4] Nagoya Univ, Grad Sch Med, Dept Integrated Hlth Sci, 1-1-20 Daiko Minami,Higashi Ku, Nagoya, Aichi 4618673, Japan
[5] Natl Inst Physiol Sci, Div Cerebral Integrat, Okazaki, Aichi, Japan
[6] Siemens Healthcare KK, Tokyo, Japan
[7] Nagoya Univ, Grad Sch Med, Dept Radiol, Nagoya, Aichi, Japan
[8] Ritsumeikan Univ, Res Org Sci & Technol, Kyoto, Kyoto, Japan
关键词
hemodynamics; intracranial artery; phase-contrast MR imaging; 4D flow MRI; magnetic field strength; UNRUPTURED INTRACRANIAL ANEURYSMS; SUBARACHNOID HEMORRHAGE; SHEAR-STRESS; FLOW; VELOCITY; RUPTURE; RISK; QUANTIFICATION; QUALITY; PATIENT;
D O I
10.2463/mrms.mp.2023-0016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Hemodynamics is important in the initiation, growth, and rupture of intracranial aneurysms. Since intracranial aneurysms are small, a high -field MR system with high spatial resolution and high SNR is desirable for this hemodynamic analysis. The purpose of this study was to investigate whether the accuracy of MR fluid dynamic (MRFD) results based on 3D phase -contrast MR (3D PC MR, non-electrocardiogram[ECG]-gated 4D Flow MRI) data from a human cerebrovascular phantom and human healthy subjects obtained by a 7T MR system was superior to those by a 3T MR system. Methods: 3D PC MR and 3D time of flight MR angiography (3D TOF MRA) imaging were performed on a 3T MR system and a 7T MR system for a human cerebrovascular phantom and 10 healthy human subjects, and MRFD analysis was performed using these data. The MRFD results from each MR system were then compared with the following items based on the computational fluid dynamics (CFD) results: 3D velocity vector field; correlation coefficient (R), angular similarity index (ASI), and magnitude similarity index (MSI) of blood flow velocity vectors. Results: In the MRFD results of 3D velocity vectors of the cerebrovascular phantom, noise -like vectors were observed near the vascular wall on the 3T MR system, but no noise was observed on the 7T MR system, showing results similar to those of CFD. In the MRFD results of the cerebrovascular phantom and healthy subjects, the correlation coefficients R, ASI, and MSI of the 7T MR system were higher than those of the 3T MR system, and ASI and MSI of healthy human subjects were significantly different between the two systems. Conclusions: The accuracy of high spatial resolution MRFD using the 7T MR system exceeded that of the 3T MR system.
引用
收藏
页码:88 / 102
页数:15
相关论文
共 29 条
  • [1] Hemodynamic Analysis of Cerebral AVMs with 3D Phase-Contrast MR Imaging
    Takeda, Y.
    Kin, T.
    Sekine, T.
    Hasegawa, H.
    Suzuki, Y.
    Uchikawa, H.
    Koike, T.
    Kiyofuji, S.
    Shinya, Y.
    Kawashima, M.
    Saito, N.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (12) : 2138 - 2145
  • [2] Functional MR angiography using phase contrast imaging technique at 3T MRI
    Kang, Chang-Ki
    Kim, Sang-Hoon
    Lee, Hyon
    Park, Chan-A
    Kim, Young-Bo
    Cho, Zang-Hee
    NEUROIMAGE, 2010, 50 (03) : 1036 - 1043
  • [3] Hemodynamic Changes in Patients with Arteriovenous Malformations Assessed Using High-Resolution 3D Radial Phase-Contrast MR Angiography
    Chang, W.
    Loecher, M. W.
    Wu, Y.
    Niemann, D. B.
    Ciske, B.
    Aagaard-Kienitz, B.
    Kecskemeti, S.
    Johnson, K. M.
    Wieben, O.
    Mistretta, C.
    Turski, P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (08) : 1565 - 1572
  • [4] Velocity Measurements in the Middle Cerebral Arteries of Healthy Volunteers Using 3D Radial Phase-Contrast HYPRFlow: Comparison with Transcranial Doppler Sonography and 2D Phase-Contrast MR Imaging
    Chang, W.
    Landgraf, B.
    Johnson, K. M.
    Kecskemeti, S.
    Wu, Y.
    Velikina, J.
    Rowley, H.
    Wieben, O.
    Mistretta, C.
    Turski, P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) : 54 - 59
  • [5] Atherosclerosis of middle cerebral artery: Evaluation with high-resolution MR imaging at 3T
    Li, Ming-li
    Xu, Wei-hai
    Song, Lan
    Feng, Feng
    You, Hui
    Ni, Jun
    Gao, Shan
    Cui, Li-ying
    Jin, Zheng-yu
    ATHEROSCLEROSIS, 2009, 204 (02) : 447 - 452
  • [6] Metabolic Abnormalities in the Hippocampus of Patients with Schizophrenia: A 3D Multivoxel MR Spectroscopic Imaging Study at 3T
    Meyer, E. J.
    Kirov, I. I.
    Tal, A.
    Davitz, M. S.
    Babb, J. S.
    Lazar, M.
    Malaspina, D.
    Gonen, O.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2273 - 2279
  • [7] Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics
    Isoda, Haruo
    Ohkura, Yasuhide
    Kosugi, Takashi
    Hirano, Masaya
    Alley, Marcus T.
    Bammer, Roland
    Pelc, Norbert J.
    Namba, Hiroki
    Sakahara, Harumi
    NEURORADIOLOGY, 2010, 52 (10) : 913 - 920
  • [8] Whole-Slab 3D MR Spectroscopic Imaging of the Human Brain With Spiral-Out-In Sampling at 7T
    Esmaeili, Morteza
    Strasser, Bernhard
    Bogner, Wolfgang
    Moser, Philipp
    Wang, Zhe
    Andronesi, Ovidiu C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (04) : 1237 - 1250
  • [9] Assessment of Coronary Flow Velocity Reserve in the Left Main Trunk Using Phase-contrast MR Imaging at 3T: Comparison with 15O-labeled Water Positron Emission Tomography
    Kikuchi, Yasuka
    Naya, Masanao
    Oyama-Manabe, Noriko
    Manabe, Osamu
    Sugimori, Hiroyuki
    Kudo, Kohsuke
    Kato, Fumi
    Aikawa, Tadao
    Tsutsui, Hiroyuki
    Tamaki, Nagara
    Shirato, Hiroki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (02) : 134 - 141
  • [10] Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics
    Haruo Isoda
    Yasuhide Ohkura
    Takashi Kosugi
    Masaya Hirano
    Marcus T. Alley
    Roland Bammer
    Norbert J. Pelc
    Hiroki Namba
    Harumi Sakahara
    Neuroradiology, 2010, 52 : 913 - 920