Influence of nanosecond laser surface patterning on dental 3Y-TZP: Effects on the topography, hydrothermal degradation and cell response

被引:8
|
作者
Garcia-de-Albeniz, N. [1 ,2 ]
Ginebra, M. -p. [2 ,3 ,4 ]
Jimenez-Pique, E. [1 ,3 ]
Roa, J. J. [1 ,3 ]
Mas-Moruno, C. [2 ,3 ]
机构
[1] Univ Polite cn Catalunya BarcelonaTECH, Ctr Struct Integr Reliabil & Micromech Mat CIEFMA, Dept Mat Sci & Engn, Barcelona 08019, Spain
[2] Univ Polite cn Catalunya, Dept Mat Sci & Engn, Biomat Biomech & Tissue Engn Grp BBT, Barcelona 08019, Spain
[3] Univ Politecn Catalunya BarcelonaTECH, Barcelona Res Ctr ssMultiscale Sci & Engn, Barcelona 08019, Spain
[4] Barcelona Inst Sci & Technol, Inst Bioengn Catalonia IBEC, Barcelona 08028, Spain
关键词
Zirconia; Dental implants; Laser patterning; Surface topography; Hydrothermal degradation; Osseointegration; Cell adhesion; Antibacterial; LOW-TEMPERATURE DEGRADATION; ALUMINA TOUGHENED ZIRCONIA; Y-TZP CERAMICS; IN-VITRO; OSTEOGENIC DIFFERENTIATION; BACTERIAL ADHESION; ABUTMENT MATERIAL; IMPLANT SURFACES; BIOFILM GROWTH; PART;
D O I
10.1016/j.dental.2023.10.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Laser surface micropatterning of dental-grade zirconia (3Y-TZP) was explored with the objective of providing defined linear patterns capable of guiding bone-cell response. Methods: A nanosecond (ns-) laser was employed to fabricate microgrooves on the surface of 3Y-TZP discs, yielding three different groove periodicities (i.e., 30, 50 and 100 mu m). The resulting topography and surface damage were characterized by confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). X-Ray diffraction (XRD) and Raman spectroscopy techniques were employed to assess the hydrothermal degradation resistance of the modified topographies. Preliminary biological studies were conducted to evaluate adhesion (6 h) of human mesenchymal stem cells (hMSC) to the patterns in terms of cell number and morphology. Finally, Staphylococcus aureus adhesion (4 h) to the microgrooves was investigated. Results: The surface analysis showed grooves of approximately 1.8 mu m height that exhibited surface damage in the form of pile-up at the edge of the microgrooves, microcracks and cavities. Accelerated aging tests revealed a slight decrease of the hydrothermal degradation resistance after laser patterning, and the Raman mapping showed the presence of monoclinic phase heterogeneously distributed along the patterned surfaces. An increase of the hMSC area was identified on all the microgrooved surfaces, although only the 50 mu m periodicity, which is closer to the cell size, significantly favored cell elongation and alignment along the grooves. A decrease in Staphylococcus aureus adhesion was observed on the investigated micropatterns. Significance: The study suggests that linear microgrooves of 50 mu m periodicity may help in promoting hMSC adhesion and alignment, while reducing bacterial cell attachment.
引用
收藏
页码:139 / 150
页数:12
相关论文
共 30 条
  • [1] Effect of different surface treatments on the hydrothermal degradation of a 3Y-TZP ceramic for dental implants
    Cattani-Lorente, M.
    Scherrer, S. S.
    Durual, S.
    Sanon, C.
    Douillard, T.
    Gremillard, L.
    Chevalier, J.
    Wiskott, A.
    DENTAL MATERIALS, 2014, 30 (10) : 1136 - 1146
  • [2] Nanosecond-laser patterning of 3Y-TZP: Damage and microstructural changes
    Roitero, E.
    Lasserre, F.
    Roa, J. J.
    Anglada, M.
    Mucklich, F.
    Jimenez-Pique, E.
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2017, 37 (15) : 4876 - 4887
  • [3] Hydrothermal degradation of ground 3Y-TZP
    Munoz-Tabares, J. A.
    Anglada, M.
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2012, 32 (02) : 325 - 333
  • [4] Influence of the microstructure on the life prediction of hydrothermal degraded 3Y-TZP bioceramics
    Abreu, Lais G.
    Quintino, Manara N.
    Alves, Manuel F. R. P.
    Habibe, Caroline H.
    Ramos, Alfeu S.
    Santos, Claudinei
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2020, 9 (05): : 10830 - 10840
  • [5] A review of surface topographical modification strategies of 3Y-TZP: Effect in the physicochemical properties, microstructure, mechanical reliability, and biological response
    Garcia-de-Albeniz, Nerea
    Jimenez-Pique, Emilio
    Roa, Joan Josep
    Mas-Moruno, Carlos
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2023, 43 (08) : 2977 - 3004
  • [6] Deceleration of hydrothermal degradation of 3Y-TZP by alumina and lanthana co-doping
    Nogiwa-Valdez, A. A.
    Rainforth, W. M.
    Zeng, P.
    Ross, I. M.
    ACTA BIOMATERIALIA, 2013, 9 (04) : 6226 - 6235
  • [7] Effects of Surface Treatments on Microstructural and Crystallographic changes of Dental 3Y-TZP Ceramics
    Wen Ning
    Yi Yuanfu
    Shao Longquan
    Deng Bin
    Zhang Weiwei
    Dong Limin
    Tian Jiemo
    RARE METAL MATERIALS AND ENGINEERING, 2009, 38 : 823 - 826
  • [8] 3Y-TZP ceramics with improved hydrothermal degradation resistance and fracture toughness
    Zhang, F.
    Vanmeensel, K.
    Inokoshi, M.
    Batuk, M.
    Hadermann, J.
    Van Meerbeek, B.
    Naert, I.
    Vleugels, J.
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2014, 34 (10) : 2453 - 2463
  • [9] Low temperature degradation of laser patterned 3Y-TZP: Enhancement of resistance after thermal treatment
    Roitero, E.
    Ochoa, M.
    Anglada, M.
    Muecklich, F.
    Jimenez-Pique, E.
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2018, 38 (04) : 1742 - 1749
  • [10] Investigation of mechanical properties and low-temperature degradation of dental 3Y-TZP ceramics fabricated by stereolithography in combination with microwave sintering
    Wang, Li
    Jiao, Yang
    Yao, Lian
    Sheng, Yang
    Hao, Zongdong
    Tang, Weizhe
    Dou, Rui
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 148