Comparison of AO, Schatzker, and three-column classification systems in tibial plateau fractures: Impact on functional outcomes

被引:3
|
作者
Selcuk, Esref [1 ]
Erem, Murat [1 ]
Copuroglu, Cem [1 ]
Ozcan, Mert [1 ]
Ciftdemir, Mert [1 ]
机构
[1] Trakya Univ, Fac Med, Dept Orthoped & Traumatol, TR-22030 Edirne, Turkiye
关键词
Classification; health care; outcome assessment; tibial plateau fractures; OSTEOARTHRITIS; RELIABILITY;
D O I
10.52312/jdrs.2023.1256
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study aimed to compare the AO, Schatzker, and Three-Column classification systems for tibial plateau fractures, focusing on their prognostic and functional outcome prediction and influence on clinical decisions across different trauma types. Patients and methods: In this retrospective study, we examined 49 patients (36 males, 11 females; mean age: 40.6 +/- 11.8 years; range, 19 to 67 years) with tibial plateau fractures between January 2011 and January 2017. The fractures were classified using the AO, Schatzker, and three-column systems. The main outcome measurements included functional scores (Knee Injury and Osteoarthritis Outcome Score [KOOS], Hospital for Special Surgery [HSS]), range of motion (ROM), duration of hospitalization, thigh atrophy, operation time, and the development of osteoarthritis. The impact of smoking was also assessed. Results: According to the AO classification, type B fractures obtained higher KOOS and HSS scores compared to type C fractures (p=0.013 and p=0.007, respectively). According to the Schatzker classification low-energy fractures achieved higher KOOS and HSS scores than high-energy fractures (p=0.013 and p=0.026, respectively). One-column fractures had higher KOOS and HSS scores compared to two-column and three-column fractures (p=0.007 and p=0.001, respectively). Two-column fractures had a lower ROM compared to other column fractures (p=0.022). Shorter hospital stays were recorded for Schatzker low-energy fractures (p=0.016), whereas higher thigh atrophy was found in Schatzker high-energy fractures (p=0.022) and AO type C fractures (p=0.018). Longer operation times were observed in AO type C fractures (p=0.037) and Schatzker high-energy fractures (p=0.017). According to the Kellgren-Lawrence classification, AO type C fractures and three-column fractures yielded worse outcomes (p=0.039 and p=0.001, respectively). Smoking had a negative impact on functional KOOS and HSS scores across all groups (p=0.022 and p=0.001, respectively). Conclusion: This study highlights the predictive value of the AO, Schatzker, and Three-Column classification systems in determining functional outcomes and clinical data in tibial plateau fractures. Each system provides unique insights into different outcomes, suggesting their concurrent application may yield a more comprehensive prognosis.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 50 条
  • [21] A revised 3-column classification approach for the surgical planning of extended lateral tibial plateau fractures
    H. Hoekstra
    K. Kempenaers
    S. Nijs
    European Journal of Trauma and Emergency Surgery, 2017, 43 : 637 - 643
  • [22] Classification systems for tibial plateau fractures; Does computed tomography scanning improve their reliability?
    Brunner, Alexander
    Horisberger, Monika
    Ulmar, Benjamin
    Hoffmann, Alexander
    Babst, Reto
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (02): : 173 - 178
  • [23] Three-dimensional computed tomography imaging increases the reliability of classification systems for tibial plateau fractures
    Hu, Yan-Ling
    Ye, Fa-Gang
    Ji, Ai-Yu
    Qiao, Guang-Xi
    Liu, Hai-Fei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (12): : 1282 - 1285
  • [24] Open tibial plateau fractures: Infection rate and functional outcomes
    Reatiga Aguilar, Juan
    Gonzalez Edery, Eduardo
    Guzman Badran, Julio
    Molina Gandara, Juan
    Arzuza Ortega, Laura
    Rios Garrido, Ximena
    Medina Monje, Claudia
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54
  • [25] Schatzker IV tibial plateau fractures involving the posterolateral column: Higher incidence of lateral meniscus and anterior cruciate ligament injuries with suboptimal postoperative outcomes
    Peng, Jian
    Ren, Weizhi
    Feng, Bin
    Hu, Zhenghui
    Xu, Wei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (12):
  • [26] Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems
    Marongiu, Giuseppe
    Leinardi, Lorenzo
    Congia, Stefano
    Frigau, Luca
    Mola, Francesco
    Capone, Antonio
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 21 (01)
  • [27] Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems
    Giuseppe Marongiu
    Lorenzo Leinardi
    Stefano Congia
    Luca Frigau
    Francesco Mola
    Antonio Capone
    Journal of Orthopaedics and Traumatology, 2020, 21
  • [28] Is Staged Surgery Always Necessary for Schatzker Type IV-VI Tibial Plateau Fractures? A Comparison Study
    Lin, Kai-Cheng
    Huang, Fu-Ting
    Chen, Chun-Yu
    Tarng, Yih-Wen
    LIFE-BASEL, 2024, 14 (06):
  • [29] Comparison of cannulated lag screws and lateral locking plate in the treatment of Schatzker type II tibial plateau fractures
    Sevencan, Ahmet
    Senol, Mehmet Selcuk
    Misir, Abdulhamit
    Aycan, Osman Emre
    Albayrak, Akif
    Ucpunar, Hanifi
    JOINT DISEASES AND RELATED SURGERY, 2020, 31 (01) : 130 - 136
  • [30] Combined approaches for fixation of Schatzker type II tibial plateau fractures involving the posterolateral column: a prospective observational cohort study
    Sun, Hui
    Zhai, Qi-Lin
    Xu, Ya-Feng
    Wang, Yu-Kai
    Luo, Cong-Feng
    Zhang, Chang-Qing
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (02) : 209 - 221