Comparison of AO, Schatzker, and three-column classification systems in tibial plateau fractures: Impact on functional outcomes

被引:3
|
作者
Selcuk, Esref [1 ]
Erem, Murat [1 ]
Copuroglu, Cem [1 ]
Ozcan, Mert [1 ]
Ciftdemir, Mert [1 ]
机构
[1] Trakya Univ, Fac Med, Dept Orthoped & Traumatol, TR-22030 Edirne, Turkiye
关键词
Classification; health care; outcome assessment; tibial plateau fractures; OSTEOARTHRITIS; RELIABILITY;
D O I
10.52312/jdrs.2023.1256
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study aimed to compare the AO, Schatzker, and Three-Column classification systems for tibial plateau fractures, focusing on their prognostic and functional outcome prediction and influence on clinical decisions across different trauma types. Patients and methods: In this retrospective study, we examined 49 patients (36 males, 11 females; mean age: 40.6 +/- 11.8 years; range, 19 to 67 years) with tibial plateau fractures between January 2011 and January 2017. The fractures were classified using the AO, Schatzker, and three-column systems. The main outcome measurements included functional scores (Knee Injury and Osteoarthritis Outcome Score [KOOS], Hospital for Special Surgery [HSS]), range of motion (ROM), duration of hospitalization, thigh atrophy, operation time, and the development of osteoarthritis. The impact of smoking was also assessed. Results: According to the AO classification, type B fractures obtained higher KOOS and HSS scores compared to type C fractures (p=0.013 and p=0.007, respectively). According to the Schatzker classification low-energy fractures achieved higher KOOS and HSS scores than high-energy fractures (p=0.013 and p=0.026, respectively). One-column fractures had higher KOOS and HSS scores compared to two-column and three-column fractures (p=0.007 and p=0.001, respectively). Two-column fractures had a lower ROM compared to other column fractures (p=0.022). Shorter hospital stays were recorded for Schatzker low-energy fractures (p=0.016), whereas higher thigh atrophy was found in Schatzker high-energy fractures (p=0.022) and AO type C fractures (p=0.018). Longer operation times were observed in AO type C fractures (p=0.037) and Schatzker high-energy fractures (p=0.017). According to the Kellgren-Lawrence classification, AO type C fractures and three-column fractures yielded worse outcomes (p=0.039 and p=0.001, respectively). Smoking had a negative impact on functional KOOS and HSS scores across all groups (p=0.022 and p=0.001, respectively). Conclusion: This study highlights the predictive value of the AO, Schatzker, and Three-Column classification systems in determining functional outcomes and clinical data in tibial plateau fractures. Each system provides unique insights into different outcomes, suggesting their concurrent application may yield a more comprehensive prognosis.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 50 条
  • [1] AO or Schatzker? How reliable is classification of tibial plateau fractures?
    Walton, NP
    Harish, S
    Roberts, C
    Blundell, C
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2003, 123 (08) : 396 - 398
  • [2] AO or Schatzker? How reliable is classification of tibial plateau fractures?
    N. P. Walton
    S. Harish
    C. Roberts
    C. Blundell
    Archives of Orthopaedic and Trauma Surgery, 2003, 123 : 396 - 398
  • [3] Tibial plateau fractures: Reproducibility of three classifications (Schatzker, AO, Duparc) and a revised Duparc classification
    Gicquel, T.
    Najihi, N.
    Vendeuvre, T.
    Teyssedou, S.
    Gayet, L. -E.
    Huten, D.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (07) : 805 - 816
  • [4] Interobserver reliability of the Schatzker and Luo classification systems for tibial plateau fractures
    Mellema, Jos J.
    Doornberg, Job N.
    Molenaars, Rik J.
    Ring, David
    Kloen, Peter
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (04): : 944 - 949
  • [5] Revisiting the Schatzker classification of tibial plateau fractures
    Kfuri, Mauricio
    Schatzker, Joseph
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (12): : 2252 - 2263
  • [6] Computed tomography-based Three-Column Classification in tibial plateau fractures: Introduction of its utility and assessment of its reproducibility
    Zhu, Yi
    Yang, Guang
    Luo, Cong-Feng
    Smith, Wade R.
    Hu, Cheng-Fang
    Gao, Hong
    Zhong, Biao
    Zeng, Bing-Fang
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 73 (03) : 731 - 737
  • [7] Are Schatzker and AO classifications accurate enough to classify tibial plateau fractures in alpine skiers?
    Saragaglia, Dominique
    Giunta, J. C.
    Gaillot, J.
    Rubens-Duval, B.
    Pailhe, R.
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1863 - 1869
  • [8] Are Schatzker and AO classifications accurate enough to classify tibial plateau fractures in alpine skiers?
    Dominique Saragaglia
    J. C. Giunta
    J. Gaillot
    B. Rubens-Duval
    R. Pailhé
    International Orthopaedics, 2021, 45 : 1863 - 1869
  • [9] Importance of the Posterior Plate in Three-Column Tibial Plateau Fractures: A Finite Element Analysis and Clinical Validation
    Liu, Chen-dong
    Hu, Sun-jun
    Chang, Shi-Min
    Du, Shou-chao
    Xiong, Wen-feng
    Chu, Yong-qian
    ORTHOPAEDIC SURGERY, 2024, 16 (04) : 930 - 942
  • [10] Multi-detector Computed Tomographic Evaluation of Tibial Plateau Fractures with Review of Schatzker's Classification of Tibial Plateau Fractures
    Ilyas, Mohd
    Gupta, Anchal
    Sharma, Shwait
    Dev, Ghanshyam
    ADVANCES IN HUMAN BIOLOGY, 2018, 8 (03) : 164 - 168